13.07.2013 Views

Contaminated Remains Pouch - Kappler

Contaminated Remains Pouch - Kappler

Contaminated Remains Pouch - Kappler

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Waterproof <strong>Remains</strong><br />

Identification Card with<br />

Waterproof Marker<br />

Vent Canister Inside<br />

ASTM F1001 Chemical Test Battery<br />

Chemical<br />

Know What You’re Getting Into.<br />

Breakthrough Time<br />

(normalized)<br />

Acetone >480<br />

Acetonitrile >480<br />

Carbon Disulfide >480<br />

Dichloromethane >480<br />

Diethylamine >480<br />

Dimethylformamide >480<br />

Ethyl Acetate >480<br />

n - Hexane >480<br />

Methyl Alcohol >480<br />

Nitrobenzene >480<br />

Sodium Hydroxide >480<br />

Sulfuric Acid >480<br />

Tetrachloroethylene >480<br />

Tetrahydrofuran >480<br />

Toluene >480<br />

Gases<br />

Ammonia Gas >480<br />

1,3 Butadiene Gas >480<br />

Chlorine Gas >480<br />

Ethylene Oxide Gas >480<br />

Hydrogen Chloride Gas >480<br />

Methyl Chloride Gas >480<br />

For complete list of chemicals tested, visit kappler.com<br />

Heat Sealed<br />

Seams<br />

Zytron 500 Chemical<br />

Barrier Fabric<br />

Chemical Agent<br />

Bis (2-chloroethyl) sulfide<br />

(Mustard:HD)<br />

Isopropyl methylfluorophosphonate<br />

(Sarin:GB)<br />

Chlorovinyl arsinedichloride<br />

(Lewisite:L)<br />

O-ethyl S-(2-diisopropylaminoethyl)<br />

methylphosphonothiolate<br />

(Nerve:VX)<br />

Exterior Exhaust Valve<br />

Interior Exhaust Valve<br />

With ISO Thread Inside for<br />

Mounting C2A1 Canister<br />

Chemical Warfare Agent Data<br />

Breakthrough<br />

Time<br />

(Minutes)<br />

<strong>Contaminated</strong><br />

<strong>Remains</strong> <strong>Pouch</strong><br />

Gas-Tight Zipper<br />

(positioned on the<br />

side of the bag<br />

for easy access)<br />

Easy-Grasp<br />

Carrying Straps<br />

Breakthrough<br />

Criteria<br />

>480 4.0 ug/cm 2<br />

>480 1.25 ug/cm 2<br />

>480 4.0 ug/cm 2<br />

>480 1.25 ug/cm 2<br />

Agent testing was conducted at Battelle Labs in accordance with NFPA 1994-2001 Edition<br />

Standard on Protective Ensembles for Chemical / Biological Terrorism Incidents.<br />

P.O. Box 490 | 55 Grimes Drive | Guntersville, Alabama 35976 | Toll Free: 800.600.4019 | Local: 256.505.4005 | Fax: 256.505.4151 | www.kappler.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!