Methodology III - Flux measurement<br />

For non-aerated surfaces,<br />

Methane gas flux, E (mass/area/time) is calculated <strong>from</strong><br />

the follow<strong>in</strong>g equation<br />

E = ( V / A ) x ρ x ( dC / dt)<br />

V = Volume <strong>of</strong> Chamber.<br />

Ρ = Density <strong>of</strong> gas at the temperature recorded <strong>in</strong><br />

the chamber.<br />

dC/dt = L<strong>in</strong>ear <strong>in</strong>crease <strong>in</strong> the gas concentration <strong>in</strong><br />

the chamber dur<strong>in</strong>g the sampl<strong>in</strong>g period.<br />

For aerated surfaces<br />

E = ρ x C x Q / A<br />

ρ = Density <strong>of</strong> gas at the temperature recorded<br />

<strong>in</strong> the chamber.<br />

C = Sample gas concentration<br />

Q = Gas flow rate <strong>in</strong>side the gas data analyzer<br />

A = Enclosed surface area.<br />