<strong>DICOM</strong> <strong>Conformance</strong> <strong>Statement</strong>: <strong>Philips</strong> IntelliSpace Portal V4.0 Page 26 of 75<br />

Image Type 0008,0008 CS Universal System<br />

Instance Creation Date 0008,0012 DA Universal System<br />

Instance Creation Time 0008,0013 TM Universal System<br />

Instance Number 0020,0013 IS Single Value System<br />

KVP 0018,0060 DS Universal System<br />

Patient Orientation 0020,0020 CS Universal System<br />

Photometric Interpretation 0028,0004 CS Universal System<br />

Pixel Spacing 0028,0030 DS Universal System<br />

Rows 0028,0010 US Universal System<br />

Samples per Pixel 0028,0002 US Universal System<br />

Series Instance UID 0020,000E UI Universal System<br />

Slice Location 0020,1041 DS Universal System<br />

Slice Thickness 0018,0050 DS Universal System<br />

SOP Class UID 0008,0016 UI Universal System<br />

SOP Instance UID 0008,0018 UI Universal System<br />

Study Instance UID 0020,000D UI Universal System<br />

Table 21: Status Response<br />

Service Status Error Code Further Meaning Behavior<br />

Success 0000 Success Matching is successful.<br />

Failure<br />

A700 Refused - Out of resources<br />

A900 Failed - Doesn't match SOP class<br />

Cxxx Failed - Unknown reason<br />

4.2.1.3.3. (Real-World) Activity – MOVE as SCU<br />

4.2.1.3.3.1. Description and Sequencing of Activities<br />

The RWA Move Remote Images involves the retrieve of images on a remote system by moving (copying) the matching images from<br />

the remote database to another database.<br />

The operator is able to copy the selected images in a patient folder from a remote database to another, local or remote, database by<br />

means of the copy tool in the <strong>DICOM</strong> Manager data handling facility. The <strong>DICOM</strong> Manager initiates for each copy request an<br />

association to the selected peer entity (Remote AE) and uses it to send the Retrieve (C-MOVE) request (and receive the associated<br />

responses). The association is released after the final Retrieve (C-MOVE) response for the related request has been received with<br />

the status success / failure.<br />