25.09.2013 Views

Breaker Catalog - Wieland Electric

Breaker Catalog - Wieland Electric

Breaker Catalog - Wieland Electric

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

selos<br />

Thermal-Magnetic Circuit <strong>Breaker</strong>s<br />

Supplementary Protection MCBs<br />

DIN rail mount, thermal/magnetic circuit breakers.<br />

Their compact dimensions, ease of mounting and<br />

excellent performance make them ideal for the<br />

overload and short circuit protection of control<br />

components and associated wiring.<br />

- Approved to UL 1077 / CSA 235<br />

for Supplemental Applications.<br />

- Approved to UL508 for manual motor controller<br />

- 1, 2 and 3 pole units<br />

- Industry standard trip curves - C and D<br />

- Other trip curves and amperages available<br />

- 0.5A – 63A<br />

- Finger safe protection<br />

Type<br />

SIze<br />

Wire Size<br />

Max Voltage<br />

Amperage<br />

Width<br />

Approvals<br />

1 Amp<br />

Trip Curve C<br />

6 Amp<br />

Trip Curve C<br />

10 Amp<br />

Trip Curve C<br />

15 Amp<br />

Trip Curve C<br />

20 Amp<br />

Trip Curve C<br />

25 Amp<br />

Trip Curve C<br />

30 Amp<br />

Trip Curve C<br />

40 Amp<br />

Trip Curve C<br />

60 Amp<br />

Trip Curve C<br />

1 Amp<br />

Trip Curve D<br />

6 Amp<br />

Trip Curve D<br />

10 Amp<br />

Trip Curve D<br />

15 Amp<br />

Trip Curve D<br />

20 Amp<br />

Trip Curve D<br />

25 Amp<br />

Trip Curve D<br />

30 Amp<br />

Trip Curve D<br />

40 Amp<br />

Trip Curve D<br />

60 Amp<br />

Trip Curve D<br />

MCB-S-1P<br />

1 pole<br />

12-3 AWG<br />

600 V<br />

0.5 - 63 A<br />

17.5 mm<br />

MCB-S-2P<br />

2 Pole<br />

12-3 AWG<br />

600 V<br />

0.5 - 63 A<br />

35 mm<br />

MCB-S-3P<br />

3 Pole<br />

12-3 AWG<br />

600 V<br />

0.5 - 63 A<br />

52.5 mm<br />

34.223.7101.0 34.223.7201.0 34.223.7301.0<br />

34.223.7106.0 34.223.7206.0 34.223.7306.0<br />

34.223.7110.0 34.223.7210.0 34.223.7310.0<br />

34.223.7115.0 34.223.7215.0 34.223.7315.0<br />

34.223.7120.0 34.223.7220.0 34.223.7320.0<br />

34.223.7125.0 34.223.7225.0 34.223.7325.0<br />

34.223.7130.0 34.223.7230.0 34.223.7330.0<br />

34.223.7140.0 34.223.7240.0 34.223.7340.0<br />

34.223.7160.0 34.223.7260.0 34.223.7340.0<br />

34.223.8101.0 34.223.8201.0 34.223.8301.0<br />

34.223.8106.0 34.223.8206.0 34.223.8301.0<br />

34.223.8110.0 34.223.8210.0 34.223.8301.0<br />

34.223.8115.0 34.223.8215.0 34.223.8301.0<br />

34.223.8120.0 34.223.8220.0 34.223.8320.0<br />

34.223.8125.0 34.223.8225.0 34.223.8325.0<br />

34.223.8130.0 34.223.8230.0 34.223.8330.0<br />

34.223.8140.0 34.223.8240.0 34.223.8340.0<br />

34.223.8160.0 34.223.8260.0 34.223.8 360.0<br />

See Technical Data Page for Complete List of Trip Currents Available<br />

Subject to change without notice<br />

www.wieland-electric.ca

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!