Thermal-Magnetic Circuit <strong>Breaker</strong>s<br />
Supplementary Protection MCBs<br />
DIN rail mount, thermal/magnetic circuit breakers.<br />
Their compact dimensions, ease of mounting and<br />
excellent performance make them ideal for the<br />
overload and short circuit protection of control<br />
components and associated wiring.<br />
- Approved to UL 1077 / CSA 235<br />
for Supplemental Applications.<br />
- Approved to UL508 for manual motor controller<br />
- 1, 2 and 3 pole units<br />
- Industry standard trip curves - C and D<br />
- Other trip curves and amperages available<br />
- 0.5A – 63A<br />
- Finger safe protection<br />
Type<br />
SIze<br />
Wire Size<br />
Max Voltage<br />
Amperage<br />
Width<br />
Approvals<br />
1 Amp<br />
Trip Curve C<br />
6 Amp<br />
Trip Curve C<br />
10 Amp<br />
Trip Curve C<br />
15 Amp<br />
Trip Curve C<br />
20 Amp<br />
Trip Curve C<br />
25 Amp<br />
Trip Curve C<br />
30 Amp<br />
Trip Curve C<br />
40 Amp<br />
Trip Curve C<br />
60 Amp<br />
Trip Curve C<br />
1 Amp<br />
Trip Curve D<br />
6 Amp<br />
Trip Curve D<br />
10 Amp<br />
Trip Curve D<br />
15 Amp<br />
Trip Curve D<br />
20 Amp<br />
Trip Curve D<br />
25 Amp<br />
Trip Curve D<br />
30 Amp<br />
Trip Curve D<br />
40 Amp<br />
Trip Curve D<br />
60 Amp<br />
Trip Curve D<br />
MCB-S-1P<br />
1 pole<br />
12-3 AWG<br />
600 V<br />
0.5 - 63 A<br />
17.5 mm<br />
MCB-S-2P<br />
2 Pole<br />
12-3 AWG<br />
600 V<br />
0.5 - 63 A<br />
35 mm<br />
MCB-S-3P<br />
3 Pole<br />
12-3 AWG<br />
600 V<br />
0.5 - 63 A<br />
52.5 mm<br />
34.223.7101.0 34.223.7201.0 34.223.7301.0<br />
34.223.7106.0 34.223.7206.0 34.223.7306.0<br />
34.223.7110.0 34.223.7210.0 34.223.7310.0<br />
34.223.7115.0 34.223.7215.0 34.223.7315.0<br />
34.223.7120.0 34.223.7220.0 34.223.7320.0<br />
34.223.7125.0 34.223.7225.0 34.223.7325.0<br />
34.223.7130.0 34.223.7230.0 34.223.7330.0<br />
34.223.7140.0 34.223.7240.0 34.223.7340.0<br />
34.223.7160.0 34.223.7260.0 34.223.7340.0<br />
34.223.8101.0 34.223.8201.0 34.223.8301.0<br />
34.223.8106.0 34.223.8206.0 34.223.8301.0<br />
34.223.8110.0 34.223.8210.0 34.223.8301.0<br />
34.223.8115.0 34.223.8215.0 34.223.8301.0<br />
34.223.8120.0 34.223.8220.0 34.223.8320.0<br />
34.223.8125.0 34.223.8225.0 34.223.8325.0<br />
34.223.8130.0 34.223.8230.0 34.223.8330.0<br />
34.223.8140.0 34.223.8240.0 34.223.8340.0<br />
34.223.8160.0 34.223.8260.0 34.223.8 360.0<br />
See Technical Data Page for Complete List of Trip Currents Available<br />