Vin:120Vac;Load:Full;<br />

CH1:V1; CH2: Vac Start-up Time:1.69S<br />

12. Hold-up Time:<br />

Test Condition:<br />

Input:120Vac, 230Vac<br />

Load:5.0A<br />

Test Equipment:<br />

Specification:<br />

Ambient temperature:Room temperature。<br />

Vin:230Vac;Load:Full;<br />

CH1:V1; CH2: Vac Start-up Time: 708mS<br />

Vin:265Vac;Load:0.5A;<br />

CH1:V1 Overshot:1.329%<br />

1. AC Programmable Source. Maker:Chroma. Model:6530<br />

2. Smart Electronic Load. Maker: Chroma. Model:63030<br />

3. Digital Phosphor Oscilloscope. Maker: Tektronix. Model:3012<br />

Test Result: PASS<br />

>10mS when 120Vac input; >20mS when 230Vac input<br />

Date: 2008-03-09 Page: 15 of 34