DVT Report - Powerbox
DVT Report - Powerbox
DVT Report - Powerbox
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Vin:120Vac;Load:Full;<br />
CH1:V1; CH2: Vac Start-up Time:1.69S<br />
12. Hold-up Time:<br />
Test Condition:<br />
Input:120Vac, 230Vac<br />
Load:5.0A<br />
Test Equipment:<br />
Specification:<br />
Ambient temperature:Room temperature。<br />
Vin:230Vac;Load:Full;<br />
CH1:V1; CH2: Vac Start-up Time: 708mS<br />
Vin:265Vac;Load:0.5A;<br />
CH1:V1 Overshot:1.329%<br />
1. AC Programmable Source. Maker:Chroma. Model:6530<br />
2. Smart Electronic Load. Maker: Chroma. Model:63030<br />
3. Digital Phosphor Oscilloscope. Maker: Tektronix. Model:3012<br />
Test Result: PASS<br />
>10mS when 120Vac input; >20mS when 230Vac input<br />
Date: 2008-03-09 Page: 15 of 34