2-11. Function Firing<br />
a. Following repair, each rifle will be function<br />
fired, if facilities are available to direct or general support<br />
maintenance.<br />
Rounds Gas Port Change Lever Position<br />
20 Medium Full automatic (A position)<br />
20 Medium Reduced automatic (F position)<br />
If rifles do not function satisfactorily, additional rounds<br />
are authorized. Rifles that fail to meet the test are to be<br />
2-12. General<br />
Refer to table 3-1.<br />
<strong>TM</strong> 9-<strong>1005</strong>-<strong>208</strong>-<strong>35</strong><br />
corrected by replacement of defective parts or by<br />
performing such repair as required.<br />
b. All rifles are to be cleaned as soon as<br />
possible after all firing tests. Clean in accordance with<br />
instructions in paragraph 3-3. Special care will be taken<br />
to insure the bolt faces, pistons, breech end of receiver<br />
and parts subjected to powder residue are thoroughly<br />
cleaned, using rifle bore cleaner (RBC).<br />
Section V. REMOVAL AND INS ALLATION OF MAJOR COMPONENTS<br />
2-13. General<br />
The USAWECOM Depot Maintenance Work<br />
Requirements (DMWR) <strong>1005</strong>-<strong>208</strong> is available through<br />
Section VI. DEPOT MAINTENANCE INSTRUCTIONS<br />
7<br />
Commanding General, Headquarters, U.S. Army<br />
<strong>Weapons</strong> Command, ATTN: AMSWESMM-SA, Rock<br />
Island, Illinois 61201.