2-11. Function Firing<br />

a. Following repair, each rifle will be function<br />

fired, if facilities are available to direct or general support<br />

maintenance.<br />

Rounds Gas Port Change Lever Position<br />

20 Medium Full automatic (A position)<br />

20 Medium Reduced automatic (F position)<br />

If rifles do not function satisfactorily, additional rounds<br />

are authorized. Rifles that fail to meet the test are to be<br />

2-12. General<br />

Refer to table 3-1.<br />

<strong>TM</strong> 9-<strong>1005</strong>-<strong>208</strong>-<strong>35</strong><br />

corrected by replacement of defective parts or by<br />

performing such repair as required.<br />

b. All rifles are to be cleaned as soon as<br />

possible after all firing tests. Clean in accordance with<br />

instructions in paragraph 3-3. Special care will be taken<br />

to insure the bolt faces, pistons, breech end of receiver<br />

and parts subjected to powder residue are thoroughly<br />

cleaned, using rifle bore cleaner (RBC).<br />

Section V. REMOVAL AND INS ALLATION OF MAJOR COMPONENTS<br />

2-13. General<br />

The USAWECOM Depot Maintenance Work<br />

Requirements (DMWR) <strong>1005</strong>-<strong>208</strong> is available through<br />

Section VI. DEPOT MAINTENANCE INSTRUCTIONS<br />

7<br />

Commanding General, Headquarters, U.S. Army<br />

<strong>Weapons</strong> Command, ATTN: AMSWESMM-SA, Rock<br />

Island, Illinois 61201.