Bluetest®AB - Gigacomp
Bluetest®AB - Gigacomp
Bluetest®AB - Gigacomp
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Comparison of radiation efficiency<br />
Large near-field chamber vs. Bluetest chamber<br />
TABLE I<br />
COMPARISON OF MEASURED AND SIMULATED RADIATION EFFICIENCY<br />
Antenna<br />
Phantom Mounted Efficiency at<br />
2.45 GHz (%) [equivalent loss, dB]<br />
Simulation Near-Field Reverb<br />
HMMPA 10mm 49.0 [3.1] 38.9 [4.1] 42.8 [3.7]<br />
HMMPA 5 mm 45.0 [3.5] 37.6 [4.2] 37.1 [4.3]<br />
Monopole 58.5 [2.3] 51.0 [2.9] 53.4 [2.7]<br />
MPA-F 65.6 [1.8] 67.0 [1.7] 75.1 [1.2]<br />
MPA-S 65.7 [1.8] 61.0 [2.1] 61.2 [2.1]<br />
From measurements by Queen's University Belfast, ”In Situ Measurement of UHF Wearable Antenna<br />
Radiation Efficiency Using a Reverberation Chamber”, IEEE Antennas and Wireless Propagation Letters,<br />
Vol. 7, 2008<br />
© <strong>Bluetest®AB</strong>