Flow Charts G(SF) Series<br />

Pump Type Sample Air Drive Outlet Pressure in bar<br />

Pressure in bar 0/Atm. 50 100 500 1000 1500 2000 3000 4000<br />

G10-2 4 15.57 9.36<br />

6 15.89 12.72 6.19<br />

8 16.02 14.10 10.15<br />

G15-2 4 10.08 8.30 3.59<br />

6 11.02 9.74 7.34<br />

8 11.11 10.34 8.89<br />

G25-2 4 6.06 5.43 4.40<br />

6 6.19 5.86 5.34<br />

8 6.24 6.04 5.72<br />

G35-2 4 4.21 3.94 3.53<br />

6 4.30 4.16 3.95<br />

8 4.34 4.25 4.12 1.66<br />

G60-2 4 2.70 2.59 2.46 0.10<br />

6 2.76 2.70 2.63 1.43<br />

8 2.78 2.75 2.70 1.98 0.12<br />

G100-2 4 1.52 1.49 1.45 0.94<br />

6 1.55 1.53 1.51 1.25 0.64<br />

8 1.56 1.55 1.54 0.38 1.01 0.46<br />

G150-2 4 1.14 1.12 1.10 0.85 0.31<br />

6 1.16 1.16 1.15 1.02 0.74 0.33<br />

8 1.17 1.17 1.16 1.09 0.92 0.67 0.34<br />

G250-2 4 0.65 0.64 0.64 0.57 0.45 0.28 0.07<br />

6 0.66 0.66 0.66 0.62 0.56 0.47 0.36 0.07<br />

8 0.67 0.67 0.66 0.64 0.61 0.55 0.49 0.31 0.07<br />

G300-2 4 0.55 0.54 0.54 0.50 0.42 0.31 0.17<br />

6 0.56 0.56 0.55 0.53 0.49 0.44 0.37 0.19<br />

8 0.56 0.56 0.56 0.55 0.52 0.49 0.45 0.34 0.19<br />

G400-2 4 0.43 0.43 0.42 0.38 0.33 0.27 0.19<br />

6 0.44 0.44 0.44 0.42 0.39 0.36 0.32 0.21 0.08<br />

8 0.44 0.44 0.44 0.44 0.42 0.40 0.38 0.32 0.25<br />

G500-2 4 0.33 0.33 0.33 0.31 0.29 0.26 0.23 0.16 0.05<br />

6 0.34 0.34 0.34 0.33 0.32 0.30 0.28 0.24 0.18<br />

8 0.34 0.34 0.34 0.34 0.33 0.32 0.31 0.28 0.25<br />

Flow in l/min<br />

23<br />

Flow Charts GX<br />

Pump Type Sample Air Drive Outlet Pressure in bar<br />

Pressure in bar 0/Atm. 50 100 200 300 400 500 600 700 800<br />

GX35 4 25.00 16.67 8.44<br />

6 24.50 20.00 14.58<br />

8 23.00 21.72 17.67 9.45<br />

GX60 4 22.00 16.59 13.60 6.45<br />

6 23.00 19.06 15.77 10.00 5.21<br />

8 21.50 19.92 17.95 13.10 8.24 2.65<br />

GX100 4 8.50 7.71 7.11 6.13 4.71 1.88<br />

6 9.00 8.47 7.97 7.15 6.49 5.81 4.90 2.96<br />

8 9.00 8.47 7.97 7.15 6.49 5.84 5.09 3.99 2.35<br />

Flow in l/min<br />

Important!<br />

The flow rates as indicated in the charts have been<br />

measured with optimum cross sections of the pipes,<br />

depending on each individual pump model.<br />

To ensure a proper operation (pressure and flow) the<br />

standard port sizes of the pump shall not be reduced.<br />

MAXIMATOR<br />

Pump it.