71 III E
71 III E
71 III E
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
P RODUCT<br />
I NFORMATION<br />
DOOR, BALLASTIC VAULT, SECURITY<br />
In accordance with the latest revision of Federal Specification AA-D-600. NOTE: Right hand swing means hinges are on the<br />
right side of the door when facing the door, outside vault. Refer to the “Ordering Checklist” for important ordering information.<br />
CLASS 5<br />
Resistant to 20 man-hours surreptitious entry, 30 man-minutes covert entry, and 10 man-minutes forced entry<br />
DESIGN B<br />
No exterior hardware<br />
STYLE K<br />
Key-change combination lock<br />
58 Type IR – right opening swing, with optical device<br />
Gray <strong>71</strong>10-01-475-8822<br />
59 Type IL – left opening swing, with optical device<br />
Gray <strong>71</strong>10-01-475-8826<br />
60 Type IIR – right opening swing, without optical device<br />
Gray <strong>71</strong>10-01-475-8820<br />
61 Type IIL – left opening swing, without optical device<br />
Gray <strong>71</strong>10-01-475-8823<br />
62 Type <strong>III</strong>R – double leaf door; right opening swing active leaf, with optical device<br />
Gray <strong>71</strong>10-01-475-8825<br />
63 SIN 489-194<br />
MODULAR VAULT SYSTEM, COMMERCIAL<br />
The vault system shall be in accordance with UL Standard 608. It shall be Class M, Class 1, Class<br />
2, or Class 3 as defined in the UL Standard. Acceptable evidence of the modular vault system<br />
meeting the requirements of UL Standard 608 shall be the UL label or listing mark, or a certified test<br />
report from a recognized, independent testing laboratory, acceptable to the government, indicating<br />
that the lamps have been tested and conform to the requirements of UL Standard 608. This SIN<br />
includes all components required for the complete assembly and installation of six-sided vaults; it<br />
does not include products used to give the vault a finished interior or exterior appearance (i.e.,<br />
paneling, drywall, or carpeting).<br />
64 SIN 489-186<br />
MODULAR VAULT SYSTEM, GSA APPROVED<br />
In accordance with latest revision of Federal Specification AA-V-2737. This SIN includes all<br />
components required for the complete assembly and installation of six-sided vaults. The SIN does<br />
not include products used to give the vault a finished interior or exterior appearance (i.e., paneling,<br />
drywall, or carpeting).<br />
65 SIN 489-187<br />
DESIGN SERVICES<br />
Vault design services include a limited range of services and are intended to assist users in<br />
achieving a vault that is safe, functional, and best suited to their needs and location. Services<br />
include conversion of generic vault designs to brand specific designs, and development of<br />
component lists required for the complete vault. Vault designs, produced under this SIN, shall<br />
include only those components covered by the GSA contract and accepted options. Design services<br />
may include the use of CAD/CAP systems for vault design and component list development,<br />
development of HVAC, electrical and communication cable management plans, site surveys, and<br />
floor load analysis. Agencies must define the scope of the services required.<br />
66 SIN 489-188<br />
INSTALLATION SERVICES<br />
Installation services may include product delivery, coordination, unpacking, inspection of product for<br />
shipping damage, assembly of product to conform to the final design, and removal of packing<br />
materials. Agencies will negotiate installation on a project-by-project basis, requesting an installation<br />
price quotation. Agencies must define the scope of the installation services required.<br />
www.fss.gsa.gov 23