annexure-i copy of terms of reference and compliance ai-1 - India ...
annexure-i copy of terms of reference and compliance ai-1 - India ...
annexure-i copy of terms of reference and compliance ai-1 - India ...
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
ANNEXURE-I<br />
COPY OF TERMS OF REFERENCE AND COMPLIANCE<br />
Sr. No Terms <strong>of</strong> Reference Compliance<br />
encumbrances. The issues relating<br />
to l<strong>and</strong> acquisition <strong>and</strong> R&R should<br />
be clearly discussed in the EIA<br />
report.<br />
10. Topography <strong>of</strong> the area should be The proposed project premise is<br />
given clearly indicating whether the<br />
site requires any filling. If so, det<strong>ai</strong>ls<br />
generally pl<strong>ai</strong>n l<strong>and</strong> with a general<br />
elevation <strong>of</strong> about 208-m above MSL.<br />
<strong>of</strong> filling, quantity <strong>of</strong> fill material No major filling is envisaged.<br />
required, its source, transportation<br />
etc. should be given.<br />
However, fill material is required to<br />
some extent, which will be sourced<br />
locally.<br />
11. Impact on dr<strong>ai</strong>nage <strong>of</strong> the area <strong>and</strong><br />
the surroundings.<br />
12. Det<strong>ai</strong>ls <strong>of</strong> the Geo technical <strong>and</strong><br />
hydrological studies.<br />
13. Information regarding surface<br />
hydrology <strong>and</strong> water regime <strong>and</strong><br />
impact <strong>of</strong> the same, if any due to the<br />
project.<br />
14. One season site-specific<br />
meteorological data shall be<br />
provided.<br />
15. One complete season AAQ data<br />
(except monsoon) to be given along<br />
with the dates <strong>of</strong> monitoring. The<br />
parameters to be covered shall<br />
include SPM, RSPM, SO 2 , NOx, Hg<br />
<strong>and</strong> Ozone (ground level). The<br />
location <strong>of</strong> the monitoring stations<br />
should be so decided so as to take<br />
into consideration the pre-dominant<br />
downwind direction, population zone<br />
<strong>and</strong> sensitive receptors including<br />
reserved forests. There should be at<br />
least one monitoring station in the<br />
upwind direction. There should be<br />
at least one monitoring station in the<br />
pre dominant downwind direction at<br />
a location where maximum ground<br />
No perennial streams are present in the<br />
project site. Also, natural dr<strong>ai</strong>nage<br />
pattern <strong>of</strong> the site will not be disturbed<br />
as far as possible.<br />
Hence, no impact is envisaged on<br />
dr<strong>ai</strong>nage pattern <strong>of</strong> the area.<br />
The det<strong>ai</strong>ls are presented in Section-<br />
4.2.5 <strong>of</strong> Chapter-4, Page:C4-3<br />
Acquisition <strong>of</strong> the l<strong>and</strong> is under<br />
progress det<strong>ai</strong>led Geo Technical<br />
studies will be carried out after<br />
acquisition <strong>of</strong> l<strong>and</strong> <strong>and</strong> placing order<br />
for equipments.<br />
The det<strong>ai</strong>ls are presented in Section-<br />
4.2.5 <strong>of</strong> Chapter-4, Page:C4-3<br />
Det<strong>ai</strong>ls are presented in section- 3.3<br />
<strong>of</strong> Chapter: 3, Page: C3-1 to 12.<br />
Site specific wind rose for Premonsoon<br />
season is presented in<br />
Figure-3.3.3, <strong>of</strong> Chapter-3, page: C3-<br />
12.<br />
AAQ sampling Locations are decided<br />
based on predominant wind directions<br />
(Downwind <strong>and</strong> Upwind direction),<br />
population zone <strong>and</strong> sensitive<br />
receptors including reserved<br />
/protected forests.<br />
The location det<strong>ai</strong>ls are presented in<br />
section-3.4, <strong>of</strong> Chapter-3, page: C3-<br />
13 to C3-19.<br />
AAQ has been monitored covering<br />
Post-monsoon season <strong>of</strong> 2009 (1 st<br />
October to 31 st December, 2009) <strong>and</strong><br />
additional two locations were<br />
monitored in pre-monsoon 2010. The<br />
summary <strong>of</strong> AAQ results are presented<br />
in Table-3.4.5, <strong>of</strong> Chapter-3 page: C3-<br />
19 <strong>and</strong> Annexure-VI.<br />
AI-6