12.02.2014 Views

Harvia electric sauna heaters - Piscine - SPA - Saune

Harvia electric sauna heaters - Piscine - SPA - Saune

Harvia electric sauna heaters - Piscine - SPA - Saune

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

+1h<br />

3<br />

+<br />

-<br />

C80/1, C90, C150 Sensor C150VKK, C260 Power unit C105S Logix<br />

Type<br />

C80/1<br />

Separate sensor included<br />

230 V 1N ~<br />

max 8 kW<br />

C90<br />

Separate sensor included<br />

400 V 3 N ~<br />

max 9 kW<br />

For <strong>heaters</strong><br />

JM20E–JM30E (2–3 kW)<br />

D23E–D36E (2,3–3,6 kW)<br />

KV30E–KV80E (3–8 kW)<br />

M45E–M80E (4,5–8 kW)<br />

HH6 (6 kW)<br />

JM20E–JM30E (2–3 kW)<br />

D23E–D36E (2,3–3,6 kW)<br />

KV30E–KV80E (3–8 kW)<br />

M45E–M90E (4,5–9 kW)<br />

HH6–HH9 (6–9 kW)<br />

Functions<br />

Digital control unit<br />

- Digital temperature display, max. +125 °C<br />

- Temperature adjustment range +(40–110) °C<br />

Digital control unit<br />

- Digital temperature display, max. +125 °C<br />

- Temperature adjustment range +(40–110) °C<br />

Times<br />

- Operating 4 h<br />

(alternatively 6 or 12 h)<br />

- Pre-setting time 0–12 h<br />

- Operating 4 h<br />

(alternatively 6 or 12 h)<br />

- Pre-setting time 0–12 h<br />

223<br />

Fenix<br />

(SACF10)<br />

250 70<br />

C150<br />

Separate sensor included<br />

400 V 3 N ~<br />

max 15 kW<br />

JM20E–JM30E (2–3 kW)<br />

D23E–D36E (2,3–3,6 kW)<br />

KV30E–KV80E (3–8 kW)<br />

M45E–M90E (4,5–9 kW)<br />

T9–T10,5 (9–10,5 kW)<br />

HH6–HH12 (6–12 kW)<br />

F10,5–F15 (10,5–15 kW)<br />

K11G–K15G (11–15 kW)<br />

Digital control unit<br />

- Digital temperature display, max. +125 °C<br />

- Temperature adjustment range +(40–110) °C<br />

- Operating 4 h<br />

(alternatively 6 or 12 h)<br />

- Pre-setting time 0–12 h<br />

Sensor<br />

51<br />

C150VKK<br />

Separate sensor included<br />

400 V 3 N ~<br />

max 15 kW<br />

JM20E–JM30E (2–3 kW)<br />

D23E–D36E (2,3–3,6 kW)<br />

KV30E–KV80E (3–8 kW)<br />

M45E–M90E (4,5–9 kW)<br />

T9–T10,5 (9–10,5 kW)<br />

HH6–HH12 (6–12 kW)<br />

F10,5–F15 (1O,5–15 kW)<br />

K11G–K15G (11–15 kW)<br />

Digital control unit<br />

- Digital temperature display, max. +125 °C<br />

- Temperature adjustment range +(40–110) °C<br />

- Week timer and remote control function<br />

- Operating 12 h<br />

(alternatively 6 or 18 h)<br />

- In manual operation, the operating<br />

time is 0–12 h at half-hour intervals<br />

73<br />

27<br />

C260<br />

Control unit, 2-group power<br />

unit and separate sensor<br />

included<br />

400 V 3 N ~<br />

16A, max 22 kW<br />

25A, max 34 kW<br />

F16,5–F18 (16,5–18 kW)<br />

K11G–K15G (11–15 kW)<br />

L20–L33 (20–33 kW)<br />

Digital control unit, 2-group power unit<br />

- Digital temperature display, max. +125 °C<br />

- Temperature adjustment range +(40–110) °C<br />

- Week timer and remote control function<br />

- Operating 12 h<br />

(alternatively 6 or 18 h)<br />

- In manual operation, the operating<br />

time is 0–12 h at half-hour intervals<br />

- Can be modified for 3-shift use<br />

Power unit<br />

KA3<br />

(optional)<br />

Cover with a lock for control units<br />

C150, C150VKK and C260<br />

350<br />

C105S Logix<br />

Control unit and two sensors<br />

400 V 3 N ~<br />

max 10,5 kW<br />

(K15GS, max 15,5 kW)<br />

Fenix<br />

400 V 3 N ~<br />

SACF10 wireless control unit<br />

for controlling power units.<br />

SACF150 power unit for<br />

controlling <strong>heaters</strong><br />

D29S (2,9 kW)<br />

KV50SE/A–KV90SE/A (5–9 kW)<br />

T7C/A–T9C/A (7–9 kW)<br />

K11GS–K15GS (10,3–15,5 kW)<br />

JM20E–JM30E (2–3 kW)<br />

D23E–D36E (2,3–3,6 kW)<br />

KV30E–KV80E (3–8 kW)<br />

M45E–M90E (4,5–9 kW)<br />

HH6–HH9 (6–9 kW)<br />

T9–T10,5 (9–10,5 kW)<br />

F10,5 (10,5 kW)<br />

SS20/A<br />

SACF150 power unit for controlling<br />

same <strong>heaters</strong> as C150 control unit.<br />

Digital control unit<br />

- Digital temperature display, max. +125 °C<br />

- Temperature adjustment range +(40–110) °C<br />

- Heater control<br />

- Steamer control, RH 10–95%<br />

- Combined heater and steamer control<br />

- User-prompting touch screen.<br />

- Features to control:<br />

- temperature<br />

- humidity<br />

- lights<br />

- colour lights<br />

- ventilation<br />

- week timer<br />

- Operating 4 h (adjustable)<br />

- Pre-setting time 0–12 h<br />

- adjustable operating time<br />

- adjustable pre-setting time<br />

280 112<br />

SACF10<br />

102<br />

155 39<br />

SACF150, SACF165S<br />

350<br />

66<br />

SACF165S power unit for<br />

controlling Combi heater or<br />

heater and separate steamer<br />

SACF100 power unit for<br />

controlling colour light<br />

SACF165S power unit for controlling<br />

same <strong>heaters</strong> as C105S control unit<br />

and also following models:<br />

HH12 (12 kW)<br />

F15 (15 kW)<br />

K11G –K15G (11 –15 kW)<br />

SACF100<br />

321 66<br />

145<br />

205