Lighting<br />
The design of a lighting scheme and the light fittings<br />
themselves can have a positive impact on the aesthetic<br />
values of an interior as well as being functional.<br />
Uniformly bright lighting throughout a building will not<br />
be in keeping with the character of an interior that was<br />
historically lit by daylight, supplemented by candles,<br />
oil or gaslight as necessary. Historic decoration and<br />
architectural detailing will have been designed to be<br />
seen in such conditions. The most sympathetic lighting<br />
therefore will simply reinforce natural light in the<br />
daytime, while night time lighting will reflect historic<br />
methods of illumination. Where advice on new lighting<br />
is needed there are considerable advantages in seeking<br />
it from independent consultants rather than from<br />
lighting suppliers or contractors.<br />
Changes in lighting regimes and technology can make<br />
an important contribution to the building’s energy<br />
efficiency. European Union directives are steadily<br />
reducing the availability of the most inefficient forms<br />
of incandescent lamps (i.e. light bulbs) so new light<br />
sources will need to be found for places of worship<br />
over the next few years. The cost of purchase, length<br />
of life, quality of light and appearance of the lamp are all<br />
considerations in choosing which type of lamp to use.<br />
New lighting should be installed in a manner that<br />
minimises physical impacts on historic fabric and<br />
reduces visual intrusion. Accessibility for maintenance<br />
is also a major consideration. Pendant lighting is often<br />
a practical and sympathetic means of providing<br />
functional lighting and can be designed to be an<br />
adornment to the building. Spot or flood lighting is the<br />
most common alternative to pendant lighting, and can<br />
sometimes be employed to dramatic effect, although<br />
the equipment can be obtrusive and its location needs<br />
careful consideration.<br />
External floodlighting schemes should avoid<br />
causing light pollution and may not be appropriate,<br />
particularly for isolated rural churches. Archaeological<br />
advice may be required in respect of sunken lamps<br />
and cabling routes.<br />
BsEST Practice 5: Principles of Conservation<br />
Practice [lighting] (2010)<br />
External Lighting for Historic Buildings (2007)<br />
Energy efficiency<br />
Historic places of worship are unlikely ever to equal the<br />
environmental performance of new-build structures,<br />
designed in conformity with modern Building<br />
Regulations. Nevertheless, more energy efficient use of<br />
buildings can normally be achieved and congregations<br />
wishing to address this issue are advised to draw up<br />
a comprehensive energy strategy for their place of<br />
worship and associated land and structures. This should<br />
identify measures to reduce the existing level of energy<br />
use, which typically have little impact on the significance<br />
of a building. Such measures might include:<br />
• changing the patterns of heating and lighting in the<br />
building and controlling them more efficiently<br />
• upgrading equipment such as boilers and light bulbs<br />
• the provision of better insulation and the elimination<br />
of draughts (without impeding necessary ventilation)<br />
Government planning guidance recognises the<br />
desirability of taking measures to respond to climate<br />
change, but requires that the public benefits of<br />
renewable energy projects are weighed against any<br />
harm to the significance of a listed building or other<br />
designated asset. Some measures which might be<br />
suitable in other contexts, for instance secondary<br />
glazing, are unlikely to be sympathetic to an historic<br />
place of worship and we would discourage their use.<br />
As an adjunct to the installation of efficient heating and<br />
environmental controls, micro-generation equipment<br />
such as solar panels can be beneficial for overall energy<br />
efficiency. In general, we would support the provision<br />
of micro-generating equipment if the visual impact<br />
is minimal, the installation of the equipment causes<br />
minimal damage to historic fabric and is reversible and<br />
the need for it can be demonstrated in the context of<br />
the energy strategy for the place of worship.<br />
Energy Efficiency and Historic Buildings (2011)<br />
Microgeneration in the Historic Environment (2008)<br />
www.climatechangeandyourhome.org.uk<br />
Types of renewable energy generation<br />
(microgeneration)<br />
The following paragraphs summarise <strong>English</strong> <strong>Heritage</strong>’s<br />
views on the methods of microgeneration most<br />
commonly considered for use at places of worship<br />
Ground source heat pumps<br />
In many places the ground disturbance necessary for<br />
ground source heat pumps – either a deep pit or a<br />
large, shallow area – will have serious implications for<br />
archaeological remains. This is likely especially at sites<br />
which have been occupied for several centuries. An<br />
archaeological assessment of the affected area should<br />
be made at an early stage to find out what<br />
the constraints are. Ground source heat pumps<br />
generally work well with underfloor heating systems<br />
(see p.15).<br />
Air source heat pumps<br />
Minimising visual impact and damage to historic fabric<br />
caused by air source heat pumps, inside and outside a<br />
place of worship, can be very difficult and as a result<br />
we discourage their use in most cases. They can<br />
sometimes be installed in a church tower, if there is<br />
a silence chamber or other such space that is wellventilated;<br />
otherwise, heat exchange units outside the<br />
building would need to be screened or positioned in<br />
such a way that their visual impact is minimised. With<br />
ingenious use of existing service runs and breaches in<br />
masonry it might be possible to make the necessary<br />
pipework and ducting less obtrusive and physically<br />
damaging. The location of condenser units inside the<br />
building would need to take account of monuments<br />
Other piped services<br />
The provision of toilets or kitchen facilities will<br />
require water, drainage and ventilation. A prior<br />
archaeological assessment will usually be required<br />
in order to establish the impact of such installations.<br />
Subject to archaeological advice, these should be<br />
routed underground rather than directly through walls.<br />
The use of composting or macerating lavatories can<br />
remove or reduce the need for drainage trenches.<br />
In rural buildings where use is not heavy and where<br />
space allows, the Trench Arch system can avoid deep<br />
excavation and complex drainage.<br />
Ventilation for toilets and kitchens can often be<br />
discreetly provided, for example, within the upper<br />
stages of towers, by introducing mesh grilles into<br />
windows or flush, cast-metal or stone-tile grilles into<br />
walls, or by setting the vent-pipe back in the wall and<br />
fitting stone or slate louvres. New ducts drilled through<br />
historic masonry should be avoided wherever possible,<br />
as should external fan units and cowls.<br />
and other significant features of the interior. Such<br />
systems are noisy in operation (similar to the noise of<br />
an air-conditioning unit) and usually require planning<br />
permission from the local planning authority.<br />
Solar panels and solar ‘slates’<br />
Since roofs are often highly visible and make a major<br />
contribution to the character of the building in its<br />
setting, putting solar panels or slates on them can<br />
potentially cause substantial harm to significance. The<br />
possibilities for installation will depend upon the form<br />
of the roof and the situation of the building. Shallowpitched<br />
roofs behind parapets and valley roof slopes<br />
are most likely to be able to accommodate solar panels<br />
with minimal visual impact. An alternative may be a<br />
ground-mounted solar collector or finding another, less<br />
sensitive building on which to put the equipment.<br />
Even when carefully designed and managed, the<br />
installation, maintenance and eventual decommissioning<br />
of solar electric panels or solar slates is likely to cause<br />
some damage to the existing historic fabric of a place<br />
of worship. To mitigate this it is important that the<br />
means of fixing, maintenance and eventual removal of<br />
the panels or slates are planned and agreed in advance.<br />
Equipment should be located so that it does not<br />
impede rainwater disposal or hinder maintenance work<br />
such as cleaning gutters.<br />
Solar Electric (Photovoltaic) Panels and Slates on Listed<br />
Places of Worship (2011)<br />
Small-scale solar electric (photovoltaics) energy and<br />
traditional buildings (2008)<br />
Drainage and groundworks<br />
A degree of dampness is not uncommon in the walls of<br />
old churches, especially where external ground levels<br />
have risen over time. Ground lowering (sometimes<br />
associated with the laying of drains) is not normally<br />
recommended as a remedy for this since it is likely to<br />
damage archaeological features, foundations and wall<br />
surfaces, and may lead to excessive drying out with<br />
subsequent cracking and even subsidence.<br />
Rainwater is best disposed of by downpipes to gulleys<br />
and soakaways, thereby getting water away from the<br />
walls of the building. Dampness is best managed by<br />
regular clearance of gutters and downpipes, good<br />
ventilation and by allowing for permeability in the wall<br />
surfaces through the use of ‘breathable’ mortars, plasters<br />
and finishes.