Technical Rider - Theater am Tanzbrunnen, Cologne - State 07.2011
Technical Rider - Theater am Tanzbrunnen, Cologne - State 07.2011
Technical Rider - Theater am Tanzbrunnen, Cologne - State 07.2011
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
2 Installation of light equipment <strong>Theater</strong> <strong>am</strong> <strong>Tanzbrunnen</strong><br />
Please note: details about stock and positions may vary<br />
2.1 Lighting: Hall<br />
1x Hall lighting ceiling- and wall l<strong>am</strong>ps<br />
36x PAR 64 Spotlights for architecture lighting<br />
12x Strand Coda Flood light for audience Illumination<br />
66x Expolight TourLED 42 Spotlights for decorative Illumination<br />
2.2 Lighting: Stage<br />
6x Strand Castor Fresnel spot 2kW (pole operated) Fronttruss 1<br />
4x Strand Castor Fresnel spot 2kW (pole operated) Fronttruss 2<br />
8x Strand Castor Fresnel spot 2kW (pole operated) Stage<br />
8x 6er Bar PAR 64 6x PAR spot 1 kW at a bar<br />
Stage<br />
(Red #106 / Blue #119 / Amber #158)<br />
4x 4er Bar PAR 64 Ray 4x PAR spot 500W at a bar (n.c.) Stage<br />
2.3 FOH (Light)<br />
1x Grand MA Full Size Lightdesk<br />
1x PANI Follow-Spot 1,2 kW HMI<br />
2.4 Dimmer<br />
1x 120Ch / 240 kW Rack (partly used by installed lighting equipment)<br />
2.5 Staff<br />
General rule: Technician labour time for set up, operation and dismantling will be supplied as per<br />
requirement, but with a minimum of 4 h per technician and job, and 6 h for hands. Services will be billed as<br />
per agreement based on actual expenditure of work time.<br />
If the in-house lighting system of the <strong>Tanzbrunnen</strong> is to be used, an operator or standby technician from<br />
müllermusic must be present from the start of set up to the end of dismantling after the event. This also<br />
pertains if an external firm of technicians is to operate the in-house system, which is of course also possible.<br />
The only situation not requiring the constant presence of a technician from müllermusic: take-over of a DMXsignal<br />
supplied by an external firm. In this case, however, the external technicians have no access to the<br />
FOH of the <strong>Tanzbrunnen</strong>. Their FOH must be positioned in the audience-area. At a pre-defined time<br />
müllermusic will take over a DMX-signal from this external company. Once the system has been inspected /<br />
accepted by the external firm the müllermusic technician can then leave. Withdrawal / technical check of the<br />
in-house lighting system will be handled as per agreement. The charges for the müllermusic technician will<br />
be billed as described herein.<br />
3 Power Supply<br />
1x 63 A CEE Stage left<br />
1x 32 A CEE Stage left<br />
1x 16 A CEE Stage left<br />
3x 63 A CEE Stage right (Dimmerraum) max. 90 kW<br />
1x 63 A CEE FOH<br />
4 Additional Information<br />
Outdoor r<strong>am</strong>p on stage level with direct load in, r<strong>am</strong>p level: 0,90m<br />
Stageintegrated elevator present between basement-, stage- and hall-level<br />
There are no movable Rigging points or Trusses in the <strong>Theater</strong> <strong>am</strong> <strong>Tanzbrunnen</strong><br />
Seite 2, <strong>Technical</strong> <strong>Rider</strong> <strong>Theater</strong> <strong>am</strong> <strong>Tanzbrunnen</strong>, Stand 11.07.11