Coating Thickness Gauge LAYERCHECK 700
Coating Thickness Gauge LAYERCHECK 700
Coating Thickness Gauge LAYERCHECK 700
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>Coating</strong> <strong>Thickness</strong><br />
<strong>Gauge</strong><br />
<strong>LAYERCHECK</strong> <strong>700</strong><br />
Model <strong>700</strong> F<br />
for all non-magnetic<br />
coatings on steel<br />
Model <strong>700</strong> FN<br />
for all non-magnetic<br />
coatings on steel and all<br />
insulating coatings<br />
on non-ferrous metals<br />
testing equipment for quality management<br />
Technical Description<br />
DIN, ISO, BS, ASTM<br />
Universal probe (FN) with<br />
automatic measuring<br />
technique for<br />
measurements on steel<br />
and on non-ferrous metals
Purpose and Application<br />
The small, universally applicable thickness gauge<br />
<strong>LAYERCHECK</strong> <strong>700</strong> is used for non-destructive, fast<br />
and precise coating thickness measurements.<br />
Typical fields of application are e.g. industrial<br />
corrosion protection, expert, electroplating and paint<br />
shops, the chemical, automobile, shipbuilding and<br />
aircraft industries as well as the apparatus and<br />
machine construction.<br />
Design and Function<br />
Depending on the type of instrument, the batteryoperated<br />
coating thickness gauges are working<br />
either on the magnetic induction principle or, in<br />
addition, according to the eddy-current method<br />
(universal probe).<br />
The <strong>LAYERCHECK</strong> <strong>700</strong> F with its magnetic<br />
induction principle is suitable to be used for<br />
measurements of non-magnetic coatings such as<br />
lacquers, aluminium, chromium, copper, zinc,<br />
enamel, rubber etc., on iron or steel as well as on<br />
alloyed and hardened magnetic steel.<br />
The <strong>LAYERCHECK</strong> <strong>700</strong> FN provides the magnetic<br />
induction principle as well as the eddy-current<br />
method.<br />
The combined probe enables the measurement of<br />
appropriate coatings on the base material steel as<br />
well as on non-ferrous metals. The automatic mode<br />
for the universal probe ensures the correct<br />
measuring method regardless of whether the base<br />
material is a ferrous or non-ferrous metal. The<br />
instrument recognizes automatically and indicates<br />
the type of substrate.<br />
The probe should be held by the spring-mounted<br />
sleeve. This ensures a safe and stable positioning<br />
and a constant contact pressure. The hemispherical<br />
tip is made of hard and wear resistant material.<br />
The integrated interface RS 232 of the<br />
<strong>LAYERCHECK</strong> enables the data transfer to a PC.<br />
For data transmission the Software Msoft<strong>700</strong>0 basic<br />
edition (German/English/French) can be<br />
downloaded free of charge at<br />
www.erichsen.de/download.<br />
The portable data printer MiniPrint 4100 IR<br />
(including infrared interface) allows the printing of<br />
measured values and subsequent printing of<br />
statistical values.<br />
For measurements in badly lit surroundings the<br />
<strong>LAYERCHECK</strong> <strong>700</strong> is equipped with a large, easyto-read<br />
LC display with backlight.<br />
Technical Data<br />
Dimensions: (L x W x H)<br />
Probe:<br />
64 x 115 x 25 mm<br />
Ø 15 mm x 62 mm<br />
Measuring range:<br />
Model <strong>700</strong> F 0 - 3000 µm<br />
Model <strong>700</strong> FN<br />
0 - 2000 µm (F)<br />
0 - 2000 µm (N)<br />
Tolerance:<br />
Minimum curvature radius:<br />
Minimum measuring area:<br />
Minimum base thickness:<br />
Display:<br />
Measuring units:<br />
Calibration:<br />
Statistics:<br />
Storage from:<br />
Interface:<br />
Power supply:<br />
± (4% + 2 µm) of the<br />
measured value<br />
convex: 5 mm/0.2”<br />
concave: 25 mm/1“<br />
ø 20 mm/0.8”<br />
0.5 mm<br />
4-digit screen data<br />
(11 mm/0.44“)<br />
µm – mils to choice<br />
standard, one point, two-point<br />
of max. 9999 measuring values<br />
average value, standard deviation,<br />
number of measured values,<br />
highest/lowest measuring value<br />
Order Information<br />
RS 232 C<br />
2 alkaline round cells<br />
Ord.-No. Product Description<br />
0285.01.31 <strong>Coating</strong> <strong>Thickness</strong> <strong>Gauge</strong><br />
<strong>LAYERCHECK</strong> <strong>700</strong> F<br />
incl. probe for measurements on<br />
steel and calibration foils<br />
0286.01.31 <strong>Coating</strong> <strong>Thickness</strong> <strong>Gauge</strong><br />
<strong>LAYERCHECK</strong> <strong>700</strong> FN<br />
incl. universal probe for<br />
measurements on steel and nonferrous<br />
metals and calibration foils<br />
For more information and accessories (for example<br />
several types of calibration foils) please refer to our<br />
price list.<br />
The right of technical modifications is reserved.<br />
Group10- TBE <strong>700</strong> – III/2010