Substation Fittings<br />

Aluminium Terminal Lug Busbar to Palm<br />

Type ABT<br />

For terminating tubular aluminium busbar at switchgear palms. Castings are in<br />

high strength aluminium. Bolts and nuts are stainless steel.<br />

E<br />

B<br />

A<br />

D<br />

L<br />

B<br />

C<br />

K Bolt size<br />

T<br />

Z<br />

Cat. No.<br />

ABT20<br />

ABT30<br />

ABT40<br />

ABT50<br />

ABT54<br />

ABT57<br />

ABT63<br />

ABT64<br />

ABT80<br />

ABT95<br />

ABT105<br />

O.D. Tube<br />

mm<br />

25.4<br />

31.8<br />

38.1<br />

50.8<br />

57.2<br />

60.3<br />

61.0<br />

63.5<br />

80.0<br />

76.2<br />

88.9<br />

No. of holes<br />

in Palm<br />

2<br />

2<br />

4<br />

4<br />

---<br />

---<br />

2<br />

4<br />

4<br />

---<br />

---<br />

A<br />

38<br />

38<br />

67<br />

83<br />

83<br />

83<br />

83<br />

83<br />

83<br />

83<br />

102<br />

B<br />

38<br />

38<br />

38<br />

50<br />

---<br />

---<br />

50<br />

50<br />

50<br />

---<br />

---<br />

Note: Details of unlisted sizes available on request.<br />

Fittings on this page have a minimum current rating, in line with the maximum<br />

Australian Standard conductor size or busbar size that the fitting can accept.<br />

C<br />

16<br />

16<br />

16<br />

16<br />

---<br />

---<br />

30<br />

16<br />

15<br />

---<br />

---<br />

www.dulmison.com.au<br />

Dimensions mm<br />

D E K<br />

83<br />

83<br />

76<br />

76<br />

80<br />

83<br />

83<br />

83<br />

83<br />

83<br />

83<br />

83<br />

83<br />

86<br />

100<br />

105<br />

108<br />

100<br />

100<br />

130<br />

171<br />

140<br />

M12<br />

M12<br />

M12<br />

M12<br />

---<br />

---<br />

M12<br />

M12<br />

M12<br />

---<br />

---<br />

L<br />

162<br />

162<br />

156<br />

165<br />

168<br />

171<br />

172<br />

172<br />

172<br />

172<br />

184<br />

T<br />

10<br />

10<br />

11<br />

14<br />

14<br />

14<br />

14<br />

14<br />

16<br />

16<br />

14<br />

Z<br />

32<br />

32<br />

35<br />

42<br />

44<br />

46<br />

46<br />

46<br />

57<br />

55<br />

61<br />

14-13<br />

Substation Fittings