Tender No. DCO9894P11/KB<br />

SOQ<br />

safe execution <strong>of</strong> the job are<br />

to be supplied by the<br />

contractor.<br />

- To clean Syphon <strong>of</strong><br />

Formation Water Tank. The job<br />

involvement is as<br />

follows:<br />

Dismantling <strong>of</strong> syphon system<br />

from the tank after opening<br />

all necessary<br />

tank fittings, bolts & nuts<br />

etc., cleaning <strong>of</strong> sand, scale<br />

etc. from<br />

inside the syphon pipe,<br />

refixing <strong>of</strong> syphon system to<br />

the tank. For<br />

lifting <strong>of</strong> syphon pipe etc.,<br />

necessary lifting arrangement<br />

will be<br />

provided by <strong>OIL</strong>.<br />

20 Emulsion Treater Cleaning: Job 200.000<br />

To clean 5000/ 3500 Bbls<br />

Emulsion Treaters. The job<br />

involvement is as<br />

follows:<br />

Isolation <strong>of</strong> the pressure<br />

vessel from the flow-stream<br />

<strong>of</strong> the<br />

installation and its<br />

depressurization, removal/<br />

skimming <strong>of</strong> oil, opening<br />

<strong>of</strong> 2 (two) nos. <strong>of</strong> oval<br />

shaped manhole doors by<br />

unscrewing bolts and<br />

nuts, removing <strong>of</strong> gaskets,<br />

use <strong>of</strong> pressurized water<br />

inside the vessel<br />

with flexible rubber hose,<br />

removing <strong>of</strong> sand, scale etc.<br />

using spade,<br />

shovel or tools <strong>of</strong> such kind<br />

to scrap <strong>of</strong>f any deposited<br />

sand, scale etc,<br />

fixing up <strong>of</strong> the manhole<br />

doors with proper gaskets,<br />

closing <strong>of</strong> 4" drain<br />

valve and testing the vessel<br />

up to the working pressure <strong>of</strong><br />

the vessel<br />

for 24 hours, removal <strong>of</strong><br />

sand, deposits etc. from the<br />

site <strong>of</strong> the vessel<br />

and transfer the same to<br />

suitable site shown by the<br />

Installation<br />

Contractor 2 Company