3UF5 SIMOCODE-DP System Motor Protection and Control Device

3UF5 SIMOCODE-DP System Motor Protection and Control Device

3UF5 SIMOCODE-DP System Motor Protection and Control Device

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

s<br />

<strong>3UF5</strong> <strong>SIMOCODE</strong>-<strong>DP</strong> <strong>System</strong> <strong>Motor</strong><br />

<strong>Protection</strong> <strong>and</strong> <strong>Control</strong> <strong>Device</strong>


Contents<br />

Page<br />

The <strong>3UF5</strong> <strong>SIMOCODE</strong>-<strong>DP</strong> <strong>System</strong> 3<br />

Thermistor-Type <strong>Motor</strong> <strong>Protection</strong><br />

Without Compromise 4<br />

Wide Scope of <strong>Control</strong> Functions 5<br />

Extensive Diagnostics 7<br />

Communication – PROFIBUS-<strong>DP</strong> 8<br />

Exchange of Data 10<br />

Simple Start-Up 12<br />

Price Advantage with <strong>SIMOCODE</strong>-<strong>DP</strong> 14<br />

Modular <strong>Device</strong> Configuration 16<br />

SIVACON –<br />

The Communications-Capable<br />

Low-Voltage Switchgear 18<br />

Technical Specifications 19<br />

2


The <strong>3UF5</strong> <strong>SIMOCODE</strong>-<strong>DP</strong> <strong>System</strong><br />

There is less <strong>and</strong> less time in between<br />

ordering <strong>and</strong> the start-up of<br />

a system – however, the requirements<br />

made on motor feeders are<br />

increasing. A system should, for<br />

example, be compact, intelligent<br />

<strong>and</strong> powerful. Every motor has<br />

optimum protection, the scope of<br />

wiring is as small as possible <strong>and</strong><br />

spares must not mean high storage<br />

costs.<br />

To meet all these requirements, the<br />

system designer has to have extensive<br />

knowledge of the complete range of<br />

low-voltage switchgear. The new<br />

communications-capable<br />

<strong>SIMOCODE</strong>®-<strong>DP</strong> <strong>3UF5</strong>0 – Siemens<br />

<strong>Motor</strong> <strong>Protection</strong> <strong>and</strong> <strong>Control</strong> <strong>Device</strong> -<br />

Decentralised Peripherals – makes life<br />

easier for the system designer.<br />

<strong>SIMOCODE</strong>-<strong>DP</strong> is a tried <strong>and</strong><br />

tested system<br />

<strong>SIMOCODE</strong> 3UF10/20 devices have<br />

been in use all over the world for more<br />

than five years. They protect <strong>and</strong><br />

control motors for the chemical, oil <strong>and</strong><br />

gas industry. <strong>Motor</strong>s with heavy<br />

starting duty as used in paper, cement<br />

<strong>and</strong> metal production for example are<br />

no problem for <strong>SIMOCODE</strong>.<br />

<strong>SIMOCODE</strong> also helps ensure that<br />

high-availability systems such as coal,<br />

gas <strong>and</strong> hydro electric plants run<br />

around the clock. <strong>SIMOCODE</strong> provides<br />

the communication between the<br />

master level <strong>and</strong> the automation level<br />

via the PROFIBUS®-FMS/SINEC®-L2-<br />

bus.<br />

The new <strong>SIMOCODE</strong>-<strong>DP</strong> <strong>3UF5</strong>0 with<br />

integrated PROFIBUS-<strong>DP</strong> interface has<br />

established itself worldwide in a short<br />

time span. It protects <strong>and</strong> controls for<br />

example Cement <strong>and</strong> Petrochemical<br />

industries in Malaysia; Paper,<br />

Chemical, Textile, Steel, Gas <strong>and</strong><br />

Waterwork plants in Europe; Chemical<br />

plants in South Africa; Food <strong>and</strong><br />

Consumergoods industries in South<br />

America <strong>and</strong> like the Steel industry in<br />

North America will soon be installed in<br />

a Steel plant in Australia.<br />

The new <strong>SIMOCODE</strong>-<strong>DP</strong> <strong>3UF5</strong>0 is<br />

based on the tried <strong>and</strong> tested<br />

<strong>SIMOCODE</strong> 3UF10/20. In addition to<br />

the existing control functions, such as<br />

direct-, reversing-, star-delta starters,<br />

there is now the possibilty to<br />

implement user-specific controls by<br />

using the freely assignable inputs <strong>and</strong><br />

outputs <strong>and</strong> the built-in truth tables,<br />

timers <strong>and</strong> counters.<br />

The existing motor protection<br />

functions (overload, phase failure <strong>and</strong><br />

current imbalance detection) have<br />

been supplemented by thermistor<br />

motor protection <strong>and</strong> earth-fault<br />

monitoring.<br />

Supervisory level<br />

Master computer<br />

<strong>Control</strong> level<br />

Automation level<br />

ETHERNET<br />

PROFIBUS-<strong>DP</strong><br />

PLC e.g.<br />

SIMATIC<br />

K1 K2 K3<br />

K4<br />

Communicationscapable<br />

low-voltage<br />

switchgear<br />

<strong>SIMOCODE</strong>-<strong>DP</strong><br />

<strong>Motor</strong><br />

<strong>Motor</strong><br />

<strong>Motor</strong><br />

Field level<br />

Fans<br />

Conveyor<br />

belt<br />

Fans<br />

3


Thermistor-Type <strong>Motor</strong> <strong>Protection</strong><br />

Without Compromise<br />

Electrical equipment such as AC<br />

motors <strong>and</strong> transformers need<br />

protection against excessive heating.<br />

Unbalanced current consumption,<br />

phase failure or a stalled rotor are<br />

some of the possible causes of<br />

overloading.<br />

Overload protection<br />

<strong>SIMOCODE</strong>-<strong>DP</strong> protects the load,<br />

independent of the automation level,<br />

against overload, phase failure <strong>and</strong><br />

current imbalance. The <strong>3UF5</strong>0 basic<br />

unit can also be used as an<br />

autonomous, solid-state overload relay<br />

for motor protection.<br />

Finely adjustable adaptation to<br />

start-up conditions<br />

It is possible to select a tripping class<br />

in six steps from CLASS 5 to CLASS<br />

30. The tripping time can be finely<br />

adjusted to the start-up conditions –<br />

<strong>and</strong> the utilisation of the motors can<br />

be optimised.<br />

Built-in thermistor motor protection<br />

Thermistor motor protection is used for<br />

the thermal protection of motors. The<br />

temperature is measured directly at<br />

the motor windings via a PTC or NTC<br />

thermistor detector <strong>and</strong> is evaluated by<br />

<strong>SIMOCODE</strong>-<strong>DP</strong>.␣ No additional<br />

evaluation devices are required, thus<br />

saving space in the switchboard.<br />

Apart from binary thermistor detectors,<br />

<strong>SIMOCODE</strong>-<strong>DP</strong> also evaluates<br />

analogous (KTY) thermistor detectors.<br />

KTY detectors incorporate a resistance<br />

curve which rises linearly with the<br />

temperature. Therefore, a warning <strong>and</strong><br />

a tripping threshold can be set in the<br />

<strong>SIMOCODE</strong>-<strong>DP</strong>.<br />

A considerable advantage.<br />

For motors with a thermally critical<br />

rotor, e.g. slipring <strong>and</strong> squirrel-cage<br />

motors with increased power, the combination<br />

of thermistor-type motor protection<br />

<strong>and</strong> electronically delayed overload<br />

relay offers full thermal protection –<br />

thermistor-type motor protection.<br />

Earth fault monitoring<br />

always available<br />

This protective function is also offered<br />

by the <strong>SIMOCODE</strong>-<strong>DP</strong> communications-capable<br />

motor protection <strong>and</strong><br />

control device. The internal earth fault<br />

detection can be activated in addition<br />

to the thermistor evaluation.<br />

4<br />

For motors with 3-wire connection,<br />

fault currents which exceed the<br />

current setting I e (during nominal<br />

operation) by 30% can be detected<br />

with the internal earth fault detection.<br />

The <strong>SIMOCODE</strong>-<strong>DP</strong> system is also<br />

suitable for a precise earth fault<br />

detection. A version is available with<br />

external earth fault detection. By<br />

connecting an external summation<br />

current transformer, fault currents of<br />

0.3 A, 0.5 A <strong>and</strong> 1 A can be detected<br />

for both 3 <strong>and</strong> 4-wire motors.<br />

An additional evaluation device is not<br />

required, <strong>and</strong> the space requirement in<br />

the cubicle is further reduced.<br />

<strong>Protection</strong> against stalled rotors<br />

<strong>Protection</strong> against the stalling of<br />

motors during normal operation is<br />

achieved by a comparison of a settable<br />

current limit.<br />

Resettable everywhere – manual,<br />

remote <strong>and</strong> automatic reset<br />

A reset at the device is implemented<br />

with the Test/Reset button. By connecting<br />

a pushbutton to the inputs, via<br />

PROFIBUS-<strong>DP</strong> or via the Test/Reset<br />

button at the operating module, a<br />

remote reset can be implemented. An<br />

automatic reset can also be<br />

configured.<br />

Reduction of variants by large<br />

setting ranges: 0.25 A – 820 A<br />

A current window from 0.25 A to<br />

820 A is covered using only six units.<br />

This reduces product selection – <strong>and</strong><br />

saves on spares costs.<br />

Tripping characteristics for 3-pole load<br />

Tripping time min<br />

s<br />

120<br />

100<br />

50<br />

20<br />

10<br />

5<br />

2<br />

1<br />

50<br />

20<br />

10<br />

5<br />

2<br />

15<br />

10<br />

Class 5<br />

Class 30<br />

25<br />

20<br />

0.6 1 2 5 10x I e<br />

Tripping current (Mean values)<br />

Tolerance < ± 10%<br />

With a tolerance of less than 10%,<br />

<strong>SIMOCODE</strong>-<strong>DP</strong> has an accurate<br />

tripping curve which guarantees an<br />

optimum utilisation of motors.<br />

Long-term stability also contributes to<br />

the high degree of accuracy.<br />

Cost reduction by built-in current<br />

transformers<br />

Current detection is archieved via three<br />

current transformers which are<br />

integrated in the device. This means that<br />

savings are made three ways – i.e.<br />

space, wiring <strong>and</strong> additional device<br />

requirements.<br />

Easy ‘through feed ‘connection<br />

Feeder cables up to 100 A rating can be<br />

easily connected to the <strong>3UF5</strong>0. The<br />

cables are not terminated to the device,<br />

but are fed through 3 integral conduits<br />

in the device housing –<br />

a major saving in installation time.<br />

<strong>Protection</strong> of motors in the EExe range<br />

The <strong>SIMOCODE</strong>-<strong>DP</strong> system complies<br />

to the regulations for overload<br />

protection of explosion-protected<br />

motors of the „increased safety“ type<br />

EExe DIN EN 50019/ DIN VDE0165,<br />

DIN VDE 0170/0171 <strong>and</strong> to the test<br />

regulations of the Federal Institute for<br />

Physics <strong>and</strong> Technology <strong>and</strong> the test<br />

requirements of the Federal Institute<br />

for Physics <strong>and</strong> Technology No. 3.53-<br />

14605/96.<br />

Tripping characteristics for 2-pole load<br />

min<br />

Tripping time<br />

s<br />

120<br />

100<br />

50<br />

20<br />

10<br />

5<br />

2<br />

1<br />

50<br />

20<br />

10<br />

5<br />

2<br />

15<br />

10<br />

Class 5<br />

Class 30<br />

25<br />

20<br />

0.6 1 2 5 10x I e<br />

Tripping current (Mean values)


Wide Scope of <strong>Control</strong> Functions<br />

With the <strong>SIMOCODE</strong>-<strong>DP</strong> system nine<br />

different control functions can be<br />

implemented:<br />

• Overload relay<br />

• Direct starter<br />

• Reversing starter<br />

• Star-delta starter<br />

• Dahl<strong>and</strong>er<br />

• Pole-changing switch<br />

• Slide valve (Encoder)<br />

• Solenoid valve<br />

• SIKOSTART® 3RW22<br />

(Soft starter)<br />

In addition, permanent or nonmaintained<br />

comm<strong>and</strong> mode can be<br />

set. All control functions can be<br />

implemented using the <strong>3UF5</strong>0 basic<br />

unit. If more than four inputs <strong>and</strong> four<br />

outputs are required, an additional<br />

eight inputs <strong>and</strong> four outputs can be<br />

fitted by using an extension module.<br />

Cost reduction by pre-defined<br />

control functions<br />

In the <strong>SIMOCODE</strong>-<strong>DP</strong>, all necessary<br />

interlocking requirements for the<br />

relevant control function (e.g. with<br />

encoders the undelayed deactivation<br />

of the motor in case of an operation of<br />

the limit or torque switch) are implemented.<br />

This offers major advantages:<br />

• Reducing the dem<strong>and</strong>s put on the<br />

user program in the programmable<br />

controller, i.e. fast planning, fewer<br />

possibilities for errors, shorter<br />

program cycle times<br />

• Time-critical functions of the<br />

motor feeder are independent of<br />

the signal process time in the<br />

automation level <strong>and</strong> on the<br />

communication system.<br />

In addition, run time checks can be set<br />

for the start or stop of motors <strong>and</strong> for<br />

the slide valve control functions in<br />

between the limits.<br />

Safety by operator enable <strong>and</strong><br />

manual/automatic switch-over<br />

In the automatic mode, control<br />

comm<strong>and</strong>s (e.g. ON, OFF) are transmitted<br />

to <strong>SIMOCODE</strong>-<strong>DP</strong> via the bus.<br />

<strong>Control</strong> comm<strong>and</strong>s from the switchgear<br />

cubicle (e.g. of the operating<br />

module) or from the local control<br />

station are only possible in this<br />

operating mode if the corresponding<br />

operator enable comm<strong>and</strong>s have been<br />

set.<br />

3/N/PE~ 50/60 Hz 400/230 V<br />

L1<br />

L2<br />

L3<br />

NPE<br />

Q1<br />

1L1<br />

2L1<br />

1N<br />

2N<br />

F11<br />

Q1<br />

RMT<br />

l ><br />

2<br />

3<br />

-K1 -K2<br />

-K3<br />

Overload<br />

Current imbalance<br />

Phase failure<br />

Thermistor<br />

Earth fault<br />

Blocking protection<br />

Current value detection<br />

1<br />

A1A2 T1T2 1 2 3 4 5<br />

230 V AC<br />

<strong>3UF5</strong>0<br />

PROFIBUS-<strong>DP</strong><br />

6 7 8 9 10 11 B A SPE/PE<br />

Ready<br />

Gen. Fault<br />

Test/<br />

Reset<br />

Switching at the<br />

cubicle door via<br />

the <strong>3UF5</strong>2<br />

operating module<br />

ON<br />

OFF<br />

2<br />

3<br />

ON<br />

OFF<br />

Local<br />

1<br />

1U 1V 1W<br />

M<br />

3~<br />

2W<br />

2U<br />

2V<br />

-K1 -K2<br />

-K3<br />

5


If the automatic level switches to<br />

manual operation, or if local control is<br />

activated by means of a local manual/<br />

automatic key switch, the bus control<br />

comm<strong>and</strong>s are ignored <strong>and</strong> the feeder<br />

can now be exclusively controlled via<br />

the operating module or using the local<br />

control station.<br />

Reduction of failure times by<br />

autonomous operation<br />

In case of system failures on the<br />

communication system, <strong>SIMOCODE</strong>-<br />

<strong>DP</strong> automatically switches to manual<br />

mode.<br />

When this occurs, the load is either<br />

switched OFF or the operating state is<br />

maintained. Further control is possible<br />

using the manual mode.<br />

Downtimes in case of failures in the<br />

automation <strong>and</strong> communication level<br />

are considerably reduced: The process<br />

can still be safely continued locally due<br />

to the autonomous structure of the<br />

<strong>SIMOCODE</strong>-<strong>DP</strong>.<br />

The process can be resumed however<br />

surely by the self-sufficient structure of<br />

the system <strong>SIMOCODE</strong>-<strong>DP</strong> locally.<br />

It means self-sufficient that all<br />

protective relay for motor <strong>and</strong> control<br />

functions are processed independently<br />

of the automation level in the<br />

<strong>SIMOCODE</strong>-<strong>DP</strong>.<br />

Flexibility due to decentralised<br />

signal logic-, delays- <strong>and</strong><br />

conditioning<br />

The great flexibility of the <strong>SIMOCODE</strong>-<br />

<strong>DP</strong> system is especially characterised<br />

by the integrated:<br />

• 3 truth tables<br />

(3 inputs with 1 output each)<br />

• 1 truth table<br />

(5 inputs with 2 outputs)<br />

• 2 timers<br />

(0.5 s...60 min; output behavior:<br />

ON delay, OFF delay, fleeting<br />

NO contact)<br />

• 2 counters<br />

(0...65535)<br />

• 4 elements of signal processing<br />

– Inverted level without memory<br />

– Rising edge with memory<br />

– Falling edge with memory<br />

• Signal conditioning<br />

– 3 flashing modules<br />

– 3 flickering modules.<br />

• 2 elements of non-resetting<br />

onvoltage failure<br />

The inputs <strong>and</strong> outputs of the system<br />

can be assigned to predefined control<br />

functions as well as to the truth tables,<br />

timers <strong>and</strong> counters. Thus, a flexible<br />

use of the predefined control functions<br />

is possible.<br />

The make/break contact behavior of<br />

the outputs is set by the signal<br />

processing modules.<br />

Selective start of the system<br />

After a mains failure, the motor feeders<br />

can be restarted using time-grading.<br />

This makes a fast <strong>and</strong> selective start of<br />

the system possible.<br />

6<br />

<strong>Control</strong> <strong>and</strong> Signalling


Extensive Diagnostics<br />

<strong>SIMOCODE</strong>-<strong>DP</strong> offers a large amount<br />

of operational <strong>and</strong> statistical data on<br />

the feeder, which is available to the<br />

user for visualisation <strong>and</strong> diagnostic<br />

purposes.<br />

This data can be accessed:<br />

• directly at the switchboard via the<br />

LED display of the h<strong>and</strong>-held-unit<br />

plugged into the basic unit or<br />

operator panel, or via a PC with<br />

Win-<strong>SIMOCODE</strong>-<strong>DP</strong>/Smart.<br />

• via PROFIBUS-<strong>DP</strong>. The data can be<br />

read by the user program <strong>and</strong> it can<br />

be transferred to a corresponding<br />

operator communication <strong>and</strong><br />

monitoring system. Thus, the various<br />

operational <strong>and</strong> statistical information<br />

can be displayed in the control room<br />

• over PROFIBUS-<strong>DP</strong>V1 with a<br />

communications processor which<br />

were in the PC/PU <strong>and</strong> the software<br />

Win-<strong>SIMOCODE</strong>-<strong>DP</strong>/Professional<br />

Always informed as to the current<br />

operating state<br />

<strong>SIMOCODE</strong>-<strong>DP</strong> continuously informs<br />

the process engineer about the current<br />

operating state:<br />

• actual phase current in %<br />

• ON/OFF<br />

• Anti-clockwise, clockwise LEFT/<br />

RIGHT<br />

• Fast, slow<br />

• Slide open, closed, moving<br />

• Warning<br />

• Fault.<br />

Reduction of failures by the<br />

signalling of critical operating<br />

states<br />

The settable current limits inform the<br />

process engineer about critical states<br />

in the system. For example, a current<br />

which is below the lower current limit<br />

setting could mean a broken conveyor<br />

belt for example. The overloading of a<br />

mixing machine for example can be<br />

quickly detected by the display of<br />

‘upper current limit exceeded.’ To avoid<br />

an overload trip of the machine, the<br />

process engineer can take precise<br />

steps to change the working process,<br />

such as reducing the amount of<br />

material in the mixer.<br />

Display of other critical operating<br />

states:<br />

• Current imbalance<br />

• Overload warning/trip<br />

• Thermistor motor protection<br />

warning/trip<br />

• Earth fault warning/trip<br />

• Locked rotor protection<br />

• Warning/trip upper/lower current<br />

limit response.<br />

Reduction of maintenance times<br />

Maintenance intervals can be<br />

increased, as all statistical data relating<br />

to the condition of a particular feeder is<br />

transmitted from the <strong>SIMOCODE</strong>-<strong>DP</strong> to<br />

the PLC. <strong>SIMOCODE</strong>-<strong>DP</strong> registers the<br />

number of starts <strong>and</strong> the number of<br />

overload trips, counts the operating<br />

hours <strong>and</strong> calculates the current in %<br />

of the last trip. All data is stored in a<br />

non-volatile memory in <strong>SIMOCODE</strong>-<strong>DP</strong>.<br />

Analogue Current display<br />

For display of analogue current value<br />

through a display device on the panel<br />

door; the <strong>SIMOCODE</strong>-<strong>DP</strong> system is<br />

provided with an external current<br />

transformer (range 0.25 A-820 A/1A).<br />

With this it is also possible for the<br />

systemselector to inform about the<br />

actual current flowing in the motor<br />

feeder.<br />

Self-monitoring<br />

The correct function of the<br />

<strong>SIMOCODE</strong>-<strong>DP</strong> processor is<br />

permanently monitored. If there is a<br />

fault, <strong>SIMOCODE</strong>-<strong>DP</strong> switches the<br />

load to the adjustement, safe state<br />

(OFF, or maintain operating state -<br />

monostable or bistable behavior).<br />

Also testable ‘in action’<br />

This function gives <strong>SIMOCODE</strong>-<strong>DP</strong><br />

additional safety <strong>and</strong> better monitoring<br />

features.<br />

The operation of <strong>SIMOCODE</strong>-<strong>DP</strong> can<br />

be checked during running – without<br />

switching off of the motor. This saves<br />

time <strong>and</strong> avoids unnecessary<br />

interruptions of the operation.<br />

Display <strong>and</strong> Diagnoses with Win-<strong>SIMOCODE</strong>-<strong>DP</strong> software<br />

7


Communication –<br />

PROFIBUS-<strong>DP</strong><br />

PC or PU with<br />

Win-<strong>SIMOCODE</strong>-<strong>DP</strong>/<br />

Professional<br />

PLC<br />

MMI<br />

with PROFIBUS-<strong>DP</strong>communicationprocessor<br />

PC or PU<br />

PROFIBUS-<strong>DP</strong>V1<br />

Online parametrization,<br />

diagnostics, control<br />

<strong>and</strong> test via acyclical<br />

reading <strong>and</strong> writing<br />

of data<br />

PROFIBUS-<strong>DP</strong><br />

Cyclical exchange of data of control-, <strong>and</strong><br />

signal data. Moreover exchange of diagnostics<br />

by changing <strong>and</strong> parameterization at communication<br />

processor running-up<br />

PC or PU with<br />

Win-<strong>SIMOCODE</strong>-<strong>DP</strong>/Smart<br />

or H<strong>and</strong>-Held-Unit<br />

PLC Programmable<br />

Logic <strong>Control</strong>ler<br />

MMI Man-Machine<br />

Interface<br />

PU/PC Programming Unit/<br />

Personal Computer<br />

<strong>3UF5</strong>0 <strong>SIMOCODE</strong>-<strong>DP</strong><br />

<strong>SIMOCODE</strong>-<strong>DP</strong> <strong>SIMOCODE</strong>-<strong>DP</strong> <strong>SIMOCODE</strong>-<strong>DP</strong><br />

From point to point,<br />

parametrization, diagnostics,<br />

control <strong>SIMOCODE</strong>-<strong>DP</strong> <strong>and</strong><br />

test via RS-232-Interface<br />

PROFIBUS-<strong>DP</strong> (Process Fieldbus -<br />

Decentralised Peripherals) provides<br />

high-performance communication<br />

between the <strong>SIMOCODE</strong>-<strong>DP</strong> <strong>and</strong> the<br />

automation level. <strong>Control</strong> comm<strong>and</strong>s,<br />

operational data, statistical data <strong>and</strong><br />

parameter data are transmitted via the<br />

two-wire bus cable. There is also the<br />

possibility to use optical link modules<br />

so that the data transmission would be<br />

effected via plastic or glass fibre optic<br />

cables.<br />

Here, the communications processor<br />

(CP/IM) plugged into the programmable<br />

logic controller (PLC) provides the<br />

management of the <strong>SIMOCODE</strong>-<strong>DP</strong><br />

Technical specifications PROFIBUS-<strong>DP</strong><br />

Total stations<br />

Transmission medium<br />

max. distance<br />

Transmission medium<br />

devices connected to the bus <strong>and</strong><br />

forms the interface to the user<br />

program. Further processing of the<br />

<strong>SIMOCODE</strong>-<strong>DP</strong> data, i.e. the integration<br />

into the supervisory control<br />

system <strong>and</strong> any subsequent<br />

processing is h<strong>and</strong>led by the user<br />

program.<br />

Short transmission times<br />

To achieve short transmission times,<br />

PROFIBUS-<strong>DP</strong> features several data<br />

channels. Up to 12 bytes can be sent<br />

cyclically from <strong>SIMOCODE</strong>-<strong>DP</strong><br />

to the automation level <strong>and</strong> up to 4<br />

bytes can be returned.<br />

30 <strong>SIMOCODE</strong>-<strong>DP</strong> per segment;<br />

with RS485 repeaters 122 <strong>SIMOCODE</strong>-<strong>DP</strong><br />

shielded, twisted, pair cable or plastic fibre<br />

glass fibre optic cable<br />

9.6 km for two-wire, 100 km for glass fibre<br />

optic cable, 425 m for plastic fibre optic cable<br />

PROFIBUS-<strong>DP</strong> (EN 50170), PROFIBUS-<strong>DP</strong>V1<br />

The diagnostic data of 20 bytes is<br />

only sent to the automation level of<br />

<strong>SIMOCODE</strong>-<strong>DP</strong> in case of a change,<br />

i.e. the diagnostic channel is eventcontrolled.<br />

213 bytes of parameter<br />

data are only sent to the <strong>SIMOCODE</strong>-<br />

<strong>DP</strong> during the start-up of the<br />

automation system.<br />

Communication –<br />

PROFIBUS-<strong>DP</strong>V1<br />

The PROFIBUS-<strong>DP</strong> st<strong>and</strong>ard has been<br />

extended around acyclic reading <strong>and</strong><br />

writing from data <strong>and</strong> with PROFIBUS-<br />

<strong>DP</strong>V1 this can be achieved. Acyclic<br />

reading <strong>and</strong> writing means for<br />

<strong>SIMOCODE</strong>-<strong>DP</strong>, that from a central<br />

workstation over PROFIBUS-<strong>DP</strong>V1<br />

with a PC or PU fitted with<br />

communicatios processor <strong>and</strong> the<br />

software Win-<strong>SIMOCODE</strong>-<strong>DP</strong>/<br />

Professional all control, diagnosis,<br />

test <strong>and</strong> parameter data can be<br />

read <strong>and</strong> written. The PROFIBUS-<strong>DP</strong>V1<br />

is a secondary protocol for the<br />

PROFIBUS-<strong>DP</strong>, <strong>and</strong> it does not<br />

require additional lines or interfaces.<br />

Transmission speed<br />

9.6, 45.45, 93.75, 187.5, 500, 1500 kBit/s<br />

8


The communication processors<br />

<strong>SIMOCODE</strong>-<strong>DP</strong> can work with any<br />

st<strong>and</strong>ard <strong>DP</strong> master which is able to<br />

read GSD files <strong>and</strong> which is capable<br />

of processing the following amounts<br />

of data:<br />

• <strong>Control</strong> data 1 or 4 byte cyclic from<br />

the <strong>DP</strong> master to <strong>SIMOCODE</strong>-<strong>DP</strong><br />

• Signalling data 1/4/12 byte cyclic<br />

from <strong>SIMOCODE</strong>-<strong>DP</strong> to the <strong>DP</strong><br />

master<br />

• Diagnosis data 20 byte acyclic from<br />

<strong>SIMOCODE</strong>-<strong>DP</strong> to the <strong>DP</strong> master<br />

• Parameter data 213 byte.<br />

For acyclic reading <strong>and</strong> writing from<br />

data the communication processor<br />

must be able the st<strong>and</strong>ard extension<br />

PROFIBUS-<strong>DP</strong>V1.<br />

Bus system exp<strong>and</strong>able<br />

If no bus system is applicable at the<br />

today‘s point in time, then can be<br />

easily re-tooled this later. Because<br />

<strong>SIMOCODE</strong>-<strong>DP</strong> processes all<br />

protective relay for motor <strong>and</strong> control<br />

functions independently of the<br />

automation level.<br />

Naturally also <strong>SIMOCODE</strong>-<strong>DP</strong> is<br />

applicable as self-sufficient protective<br />

realy for motor <strong>and</strong> controller without<br />

PROFIBUS-<strong>DP</strong> genereally.<br />

‘OUT’ without<br />

PROFIBUS-<strong>DP</strong>.<br />

Siemens <strong>and</strong> 400 other<br />

manufacturers <strong>and</strong> users<br />

of communications-capable<br />

devices fully support the<br />

EN 50170 PROFIBUS<br />

st<strong>and</strong>ard. All are members<br />

of the PROFIBUS user<br />

organisation.<br />

Today, there are more<br />

than 700 PROFIBUS-related<br />

products.<br />

See for yourself. You can<br />

get information on the highperformance<br />

PROFIBUS<br />

simply by requesting the<br />

information diskette of the<br />

PROFIBUS user<br />

organisation or via the<br />

Internet. This will give you<br />

an immediate overview of<br />

all relevant products.<br />

9


Simple Start-Up<br />

PC or PU with<br />

Win-<strong>SIMOCODE</strong>-<strong>DP</strong>/<br />

Professional<br />

PLC<br />

MMI<br />

with PROFIBUS-<strong>DP</strong>-<br />

Communication<br />

Processor<br />

PROFIBUS-<strong>DP</strong>V1<br />

Online Parameterization<br />

PROFIBUS-<strong>DP</strong><br />

Parameter data is written<br />

on every starting cycle of<br />

the communication processor<br />

PC or PU with<br />

Win-<strong>SIMOCODE</strong>-<strong>DP</strong>/Smart<br />

or h<strong>and</strong>-held-unit<br />

<strong>SIMOCODE</strong>-<strong>DP</strong> <strong>SIMOCODE</strong>-<strong>DP</strong> <strong>SIMOCODE</strong>-<strong>DP</strong><br />

Point to point parameterization<br />

over <strong>SIMOCODE</strong>-<strong>DP</strong> system<br />

interface<br />

Möglichkeiten der Parametrierung<br />

Integrating many slaves using only<br />

one software<br />

The integration of <strong>SIMOCODE</strong>-<strong>DP</strong> into<br />

a PROFIBUS-<strong>DP</strong> network is easily<br />

achieved via the parameterising <strong>and</strong><br />

service programme of COM<br />

PROFIBUS Windows 3.1 or of<br />

SIMATIC S7: Step 7 Windows 95.<br />

Call up the parameterisation <strong>and</strong><br />

service program COM PROFIBUS -<br />

open the master system under File<br />

„New“ <strong>and</strong> add the individual slaves<br />

e.g. the <strong>SIMOCODE</strong>-<strong>DP</strong>, the<br />

PROFIBUS-<strong>DP</strong> interface for the circuitbreaker<br />

or the micro master -<br />

everything with just one software.<br />

Double-click on the <strong>SIMOCODE</strong>-<strong>DP</strong><br />

icon <strong>and</strong> now the required parameters<br />

for the motor feeder can be set.<br />

<strong>SIMOCODE</strong>-<strong>DP</strong> – Online<br />

Parametrization<br />

Now the user can parameterize<br />

<strong>SIMOCODE</strong>-<strong>DP</strong> „Online“ from a<br />

central workstation through<br />

PROFIBUS-<strong>DP</strong>.<br />

So, what is meant by „Online“?<br />

Previously it was possible to transfer<br />

the slave parameters through<br />

PROFIBUS-<strong>DP</strong> only in the start-up<br />

phase of the communication processor.<br />

But now exists the possibility that<br />

besides normal cyclic data exchange,<br />

acyclic reading <strong>and</strong> writing of<br />

parameters is also possible. This<br />

means now <strong>SIMOCODE</strong>-<strong>DP</strong> can be<br />

parameterized, controlled, observed<br />

<strong>and</strong> tested from a central project<br />

engineering workstation by using Win-<br />

<strong>SIMOCODE</strong>-<strong>DP</strong>/Professional software.<br />

This central project engineering<br />

workstation should be equipped with a<br />

personnel computer (PC) or a<br />

programming unit (PU) with integrated<br />

PROFIBUS-<strong>DP</strong> communication<br />

processor. Another possibility is to use<br />

a Siemens PU, with integrated MPI<br />

interface <strong>and</strong> access the PROFIBUS-<br />

<strong>DP</strong> directly.<br />

Reduced comissioning time<br />

Now its not required to run around<br />

from switch room <strong>and</strong> parametrize the<br />

motor feeders. All <strong>SIMOCODE</strong>-<strong>DP</strong><br />

connected to PROFIBUS-<strong>DP</strong> can be<br />

parametrized from a central place.<br />

Moreover all parameters can also be<br />

read <strong>and</strong> written by that.<br />

Increased system availability<br />

In the past changing of parameters<br />

meant system deadlock. With Win-<br />

<strong>SIMOCODE</strong>-<strong>DP</strong>/Professional the<br />

parameters in <strong>SIMOCODE</strong>-<strong>DP</strong> can be<br />

modified „Online“ through PROFIBUS-<br />

<strong>DP</strong> – wihtout bringing the system to a<br />

halt.<br />

10


„Totally Integrated“ in SIMATIC S7,<br />

C7, M7, PCS7 – OM-<strong>SIMOCODE</strong>-<strong>DP</strong><br />

Win-<strong>SIMOCODE</strong>-<strong>DP</strong>/Professional is<br />

„Totally Integrated“ in SIMATIC S7/C7/<br />

M7 as well as PCS7. The call is made<br />

by STEP 7 from HW-Config. The OM-<br />

<strong>SIMOCODE</strong>-<strong>DP</strong> therby implements<br />

the data interface.<br />

This results in a unique possibility; that<br />

only with one software package one<br />

can write the PLC user programme,<br />

configure PROFIBUS-<strong>DP</strong> <strong>and</strong><br />

parameterize <strong>SIMOCODE</strong>-<strong>DP</strong> <strong>3UF5</strong> –<br />

the communication capable motor<br />

protection <strong>and</strong> control device. Use of<br />

different complex software packages is<br />

omitted thereby.<br />

Totally Integrated in SIMATIC S7/M7/C7/PCS7<br />

A plus for commisioning<br />

Another advantage of the <strong>SIMOCODE</strong>-<br />

<strong>DP</strong> system is that a motor feeder can<br />

be tested during the commisioning<br />

stage with the Win-<strong>SIMOCODE</strong>-<strong>DP</strong>/<br />

Professional software. This means,<br />

there lies a possibility, that one can<br />

switch on <strong>and</strong> off from a central<br />

workstation <strong>and</strong> also set the Testbits<br />

<strong>and</strong> enquire about the device state.<br />

Interconnectivity from <strong>SIMOCODE</strong>-<strong>DP</strong> to a PROFIBUS-<strong>DP</strong> network<br />

Parameterization with Win-<strong>SIMOCODE</strong>-<strong>DP</strong>/Professional<br />

11


Price Advantage with <strong>SIMOCODE</strong>-<strong>DP</strong><br />

Figure 1 shows the configuration of a<br />

typical communications-capable motor<br />

feeder with overload relay, thermistor<br />

motor protection device, earth fault<br />

detection, current value transmission<br />

via A/D converters <strong>and</strong> a decentralised<br />

peripheral system for the bus<br />

connection.<br />

Figures 2 <strong>and</strong> Figure 3 show the motor<br />

branch of the future.<br />

Reduced number of products<br />

cover the entire range<br />

For the complete control <strong>and</strong><br />

monitoring including connection to the<br />

PROFIBUS-<strong>DP</strong>, only <strong>SIMOCODE</strong>-<strong>DP</strong> is<br />

required. This means that no additional<br />

overload relays, thermistor evaluation<br />

devices etc. need to be installed.<br />

Reduction of the scope of wiring<br />

between field <strong>and</strong> control level<br />

Communication between the field<br />

level <strong>and</strong> the higher automation level<br />

(PLC or process control system DCS)<br />

is normally implemented via coupling<br />

devices <strong>and</strong> point-to-point connections<br />

to input <strong>and</strong> output modules of the<br />

PLC or DCS. With the application of<br />

<strong>SIMOCODE</strong>-<strong>DP</strong>, the scope of wiring is<br />

reduced to a minimum - A two-wire<br />

PROFIBUS-<strong>DP</strong> cable for up to 100<br />

motor feeder; Coupling devices <strong>and</strong><br />

input/output modules, cable gallery are<br />

not required.<br />

Reduction in wiring costs in<br />

the field level<br />

In the case of the reverser starter<br />

(figure 3) no electrical interlocking is<br />

required, <strong>and</strong> no time-delay relay which<br />

prevents a direct switch-over from<br />

clockwise to anti-clockwise rotation is<br />

necessary. Everything is implemented<br />

with <strong>SIMOCODE</strong>-<strong>DP</strong>.␣ The only thing<br />

required is to set the desired switchover<br />

delay time<br />

Without <strong>3UF5</strong><br />

With <strong>3UF5</strong><br />

-Q1<br />

-K1<br />

3UL22<br />

-K2<br />

Earth fault<br />

detection<br />

3UL21<br />

Current value<br />

transmission<br />

–<br />

4...20 mA<br />

–<br />

-Q1<br />

-K1 -K2<br />

Overload<br />

Current imbalance<br />

Phase failure<br />

Earth fault protection<br />

Thermistor<br />

Blocking protection<br />

Current value detection<br />

Overload relay<br />

3RU50<br />

PROFIBUS-<strong>DP</strong><br />

Figure 1: Well-tried technology<br />

12<br />

3UN21<br />

Thermistor<br />

motor protection<br />

M<br />

3~<br />

DI AI DO<br />

Decentralized peripherals<br />

M<br />

3~<br />

Figure 2: <strong>Motor</strong> branch of the future


L1<br />

L2<br />

L3<br />

N<br />

PE<br />

3/N/PE~ 50/60 Hz<br />

400/230 V<br />

Q1<br />

1L1<br />

1N<br />

2L1<br />

2N<br />

F11<br />

Q1<br />

RMT<br />

-K1 -K2<br />

1<br />

2<br />

4<br />

l ><br />

2<br />

4<br />

Overload<br />

Current unbalance<br />

Phase failure<br />

Thermistor<br />

Earth fault<br />

Blocking protection<br />

Current value detection<br />

A1 A2 T1T2 1 2 3 4 5<br />

230 V AC<br />

<strong>3UF5</strong>0<br />

PROFIBUS-<strong>DP</strong><br />

6 7 8 9 10 11 B A SPE/PE<br />

Ready<br />

Gen. Fault<br />

Test/<br />

Reset<br />

Anti-clockwise<br />

Clockwise<br />

Off<br />

Local<br />

M<br />

3~<br />

-1<br />

-K1 -K2<br />

Figure 3: Reversing starter with <strong>SIMOCODE</strong>-<strong>DP</strong><br />

As all functions are integrated into one<br />

device, the following savings are<br />

possible.<br />

Savings possible:<br />

device variants in<br />

the motor feeders<br />

space requirement<br />

in the cubicle<br />

the wiring cost<br />

between control level<br />

<strong>and</strong> field level<br />

scope of wiring<br />

in the unit control<br />

level<br />

start-up<br />

times<br />

spares<br />

costs<br />

13


Modular <strong>Device</strong> Configuration<br />

The modular configuration of the<br />

<strong>SIMOCODE</strong>-<strong>DP</strong> system means that it<br />

can be used as a protection <strong>and</strong><br />

control device for feeders. The system<br />

consists of the following components:<br />

<strong>3UF5</strong>0 basic unit<br />

The basic unit with four inputs <strong>and</strong><br />

four outputs implements all protection<br />

<strong>and</strong> control functions autonomously,<br />

<strong>and</strong> provides connection to the<br />

PROFIBUS-<strong>DP</strong>.␣ The four inputs are fed<br />

by the internal 24 V DC power supply.<br />

The extension module, the operating<br />

module, the manual operating device<br />

or the PC can be connected via the<br />

system interface. The basic unit is<br />

produced with three different control<br />

supply voltage<br />

(24 V DC, 115 V AC, 230 V AC).<br />

Win-<strong>SIMOCODE</strong>-<strong>DP</strong><br />

Runs on any AT-compatible PC under<br />

Windows 95 or Windows NT. For startup,<br />

diagnostics <strong>and</strong> maintenance.<br />

Manual control (ON, OFF, ...)<br />

Diagnostics (current display, fault, ...)<br />

Parameterization (address, baud rate,<br />

set current, control function, ...)<br />

Includes Online Help <strong>and</strong> parameter<br />

data examples.<br />

<strong>3UF5</strong>1 extension module<br />

The extension module additionally<br />

provides eight inputs <strong>and</strong> four outputs<br />

to the system. The device itself is fed<br />

by the basic unit. The eight inputs<br />

must be connected to an external<br />

voltage supply. Here, there are three<br />

different voltage versions (24 V DC,<br />

115 V AC, 230 V AC). The connection to<br />

the basic unit <strong>and</strong> the connection to<br />

the operating module, to the manual<br />

operating device or to the PC is via the<br />

system interface.<br />

<strong>3UF5</strong>2 operating module<br />

For manual control of a drive in the<br />

cubicle. Can be connected to the basic<br />

unit <strong>and</strong> to the extension module.<br />

Power supply from the basic unit.<br />

Connection possibilities for the manual<br />

operating device or PC. Installation in<br />

the front panel or in the IP 54 cubicle<br />

door.<br />

Three buttons can be freely<br />

parameterised. Six signalling LEDs<br />

can be freely parameterised.<br />

14


Connection of a thermistor sensor circuit<br />

for optional thermistor-type motor<br />

Connection of a summation current<br />

transformer for earth fault monitoring<br />

Connection of control<br />

supply voltage<br />

- 24 V DC<br />

- 115 V AC<br />

- 230 V AC<br />

3 LED displays<br />

<strong>Device</strong> test, manual reset<br />

- Automatic reset parameterisable<br />

- Remote reset via bus or input<br />

3 + 1 relay outputs:<br />

- Function assignment<br />

parameterizable<br />

<strong>System</strong> interface<br />

- Connection to basic unit<br />

- Power supply from basic unit<br />

3 + 1 outputs:<br />

- Function assignment<br />

parameterisable<br />

2 status LEDs<br />

3 LED displays<br />

Function assignment<br />

parameterisable<br />

<strong>Device</strong> test<br />

Manual reset<br />

A1 A2 T1 T2 1 2 3 4 5<br />

AC 230V I1 I2 I3 I4 24VDC<br />

G/9520<br />

Ready<br />

Bus<br />

Gen. Fault<br />

25...100A<br />

Test/<br />

Reset<br />

PROFIBUS-<strong>DP</strong><br />

<strong>3UF5</strong>021-3AJ00-1<br />

01 02 03 03 PROFIBUS-<strong>DP</strong><br />

Sys.<br />

3UFS<br />

6 7 8 9 10 11 B A SPE/PE<br />

20 21 22 23 24 25 26 27 28<br />

15 16 17 18 19 10 11 12<br />

Sys.<br />

3UFS<br />

G/9520<br />

05 06 07 08<br />

Sys.<br />

3UFS<br />

<strong>3UF5</strong>100-0XX00-0AA0<br />

30 31 32 33 34 35 PE<br />

Ready<br />

Gen. Fault<br />

Test/<br />

Reset<br />

4 optocoupled inputs:<br />

- 24 V DC, internally supplied<br />

- Function assignment<br />

parameterisable<br />

<strong>System</strong> interface<br />

- Connection of extension<br />

module, operating module,<br />

manual operating device or PC<br />

PROFIBUS-<strong>DP</strong> bus connection<br />

- St<strong>and</strong>ard 9-pole SUB-D socket<br />

- Terminals, e.g. for drawout unit<br />

design<br />

8 optocupled inputs:<br />

- 24 V DC, 115 V AC<br />

230 V AC, externally supplied<br />

- Function assignment<br />

parameterisable<br />

<strong>System</strong> interface<br />

- Connection of<br />

operating module,<br />

manual operating device<br />

or PC<br />

3 buttons,<br />

function assignment<br />

parameterisable<br />

3 LED displays<br />

function assignment<br />

parameterisable<br />

9-pole SUB-D socket<br />

for the connection of the<br />

manual operating device<br />

or PC<br />

3WX36 manual operating device<br />

This can be connected to the basic<br />

unit, to the extension module or to the<br />

operating module. For commisioning,<br />

diagnostics <strong>and</strong> maintenance. Manual<br />

control (ON, OFF, ...) Diagnosis<br />

(Current display, fault, ...)<br />

Parameterisation (address,<br />

baud rate, set current, control<br />

function, ...)<br />

OM-<strong>SIMOCODE</strong>-<strong>DP</strong><br />

STEP 7-Object-Manager to call Win-<br />

<strong>SIMOCODE</strong>-<strong>DP</strong>/Professional in STEP 7<br />

Connection cables with plugs<br />

Connection between basic unit,<br />

extension module or operating<br />

module.<br />

Bus terminal/bus termination<br />

modules<br />

If the PROFIBUS-<strong>DP</strong> is connected to<br />

the basic unit, the st<strong>and</strong>ard 9-pole Sub-<br />

D plugs with built-in bus terminating<br />

resistor can be used. Especially for the<br />

application of <strong>SIMOCODE</strong>-<strong>DP</strong> in <strong>Motor</strong><br />

<strong>Control</strong> Centers (MCC drawout unit<br />

design) there is a bus termination<br />

module with built-in power supply. This<br />

guarantees that even the last unit in<br />

the bus can be removed without any<br />

impairment of the data flow.<br />

Operating manual<br />

A manual for the <strong>SIMOCODE</strong>-<strong>DP</strong><br />

system is available which describes<br />

each detail of the functionality of<br />

<strong>SIMOCODE</strong>-<strong>DP</strong>. It is intended as an aid<br />

for project planning <strong>and</strong> system startup<br />

<strong>and</strong> it features a comprehensive<br />

description of the PROFIBUS-<strong>DP</strong><br />

communications interface <strong>and</strong> project<br />

examples.<br />

15


SIVACON – The Communications-Capable<br />

Low-Voltage Switchgear<br />

As well as the communicationscapable<br />

3WN6 circuit-breakers <strong>and</strong><br />

AS-Interface modules, <strong>SIMOCODE</strong>-<strong>DP</strong><br />

now provides another communications<br />

module for low-voltage switchgear.<br />

<strong>SIMOCODE</strong>-<strong>DP</strong> can be used in<br />

SIVACON® for the control of all<br />

feeders in both fixed <strong>and</strong> drawout<br />

design.<br />

High availability - no problem with<br />

SIVACON drawout design<br />

SIVACON drawout design enables the<br />

system operator to adapt quickly to<br />

changing system requirements.<br />

With the integration of <strong>SIMOCODE</strong>-<strong>DP</strong><br />

directly into the drawout units, a clear<br />

connection to the feeder <strong>and</strong> the<br />

corresponding <strong>SIMOCODE</strong>-<strong>DP</strong> is<br />

reached. A replacement of drawout<br />

units is possible without interruption of<br />

the bus connection.<br />

Technical configuration of the<br />

SIVACON switchgear with<br />

<strong>SIMOCODE</strong>-<strong>DP</strong><br />

The <strong>3UF5</strong>2 operating module is always<br />

accessible from the front <strong>and</strong> is<br />

situated in the front panel of the<br />

relevant drawout unit.<br />

The <strong>3UF5</strong>0 basic unit with the integrated<br />

current transformers is built into<br />

the inside of the drawout units.<br />

Each feeder can be adjusted <strong>and</strong><br />

controlled autonomously at the<br />

switchboard by connecting the manual<br />

operating device or a PC with the WIN-<br />

<strong>SIMOCODE</strong>-<strong>DP</strong> software to the<br />

operating module integrated into the<br />

front panel. In addition, all operation,<br />

diagnostic <strong>and</strong> statistical data<br />

determined by <strong>SIMOCODE</strong>-<strong>DP</strong> can be<br />

read.<br />

16


Technical Specification<br />

<strong>3UF5</strong>0 basic unit, <strong>3UF5</strong>1 extansion module, <strong>3UF5</strong>2 operator panel, 3WX3G h<strong>and</strong>-held-unit<br />

Permiss. ambient/storage temperature -25 °C to +60 °C/ -40 °C to +80 °C<br />

Site altitude<br />

up to 2000 m above sea level<br />

Degree of protection (in acc. IEC 529) IP 20 max. setting curent I e w 100 A; IP 00 max. setting current I e > 100 A;<br />

Shock resistance (sinewave)<br />

Mounting position<br />

Mounting<br />

10 g/5 ms<br />

free choice<br />

max. setting current I e w 100 A: snap-on mounting onto 35 mm top-hat rail or screw fixing<br />

with insertion clip<br />

max. setting current I e > 100 A: screw fixing directly to contactor of srewfiring<br />

EMC interference immunity Conducted interference, burst in acc. with IEC 61000-4-4: 2 kV (corr. to severity 3)<br />

Conducted interference, surge in acc. with IEC 61000-4-5: 2 kV (corr. to severity 3)<br />

Electrostatic discharge in acc. with IEC 61000-4-2: 8 kV (corr. to severity 3)<br />

Field-related interference in acc. with IEC 61000-4-3: 3 V/m (corr. to severity 2)<br />

(see special notes in the manual)<br />

EMC emitted interference Limit value class A in acc. with EN 55011 1991<br />

<strong>3UF5</strong>0 basic unit<br />

Display<br />

green LED „Ready“<br />

green LED „Bus“<br />

red LED „General Fault“<br />

Buttons<br />

Test/Reset<br />

<strong>System</strong> interface<br />

PROFIBUS-<strong>DP</strong> interface<br />

Main circuit<br />

Permanent light “Ready“<br />

Off “no control supply voltage“ or “function test negative, device blocked“<br />

Permanent light “Bus operation“<br />

Permanent light/flashing light “Branch fault“,␣␣e.g. overload tripping<br />

By pressing the Test/Reset button the device can be reset after a tripping or it can be<br />

tested as to its functionality<br />

RS232 for connection of extension module, operating module, manual operating device or PC<br />

RS485 for connection of the PROFIBUS-<strong>DP</strong> line via terminals (connection cross-section<br />

as with auxiliary contactors or via 9-pole SUB-D socket)<br />

Rated insulation voltage U I 690 V for blank/uninsulated conductor (<strong>3UF5</strong>001 - <strong>3UF5</strong>021)<br />

} for pollution degree 3<br />

1000 V for insulated conductor <strong>3UF5</strong>031 - <strong>3UF5</strong>051<br />

1000 V for blank/uninsulated conductor (<strong>3UF5</strong>031 <strong>and</strong> <strong>3UF5</strong>051)<br />

Rated impulse strength U imp<br />

6 kV <strong>3UF5</strong>001 - <strong>3UF5</strong>021<br />

8 kV <strong>3UF5</strong>031 - <strong>3UF5</strong>051<br />

Rated frequency <strong>and</strong> current type<br />

50 Hz/60 Hz; three-phase AC<br />

Diameter of push-through openings 10 mm (devices with max. setting current I e w 25 A)<br />

(max. I e w 100 A) 15 mm (devices with max. setting current I e 100 A)<br />

for devices with setting current I e >100 A: mounting with connection bars<br />

Busbar connection (Current range) 50 to 205 A 125 to 500 A 200 to 820 A<br />

Torque M8: 10 to 14 Nm M10: 14 to 24 Nm M10: 14 to 24 Nm<br />

M12: 20 to 35 Nm<br />

Flexible with cable lug 35 to 95 mm 2 50 to 240 mm 2 50 to 240 mm 2<br />

Str<strong>and</strong>ed with cable lug 50 to 120 mm 2 70 to 240 mm 2 70 to 240 mm 2<br />

Auxiliary circuit/control circuit<br />

Rated control supply voltage U e AC 50/60 Hz, 115 V <strong>and</strong> 230 V DC 24 V<br />

Working range AC 50/60 Hz, 0.85 to 1.1 U s DC 24 V, 0.85 to 1.2 U s (DIN 19240)<br />

Power consumption AC 50/60 Hz, 5 VA DC 24 V, 5 W<br />

Mains buffering time<br />

200 ms<br />

Rated insulation voltage U I 300 V (for pollution degree 3)<br />

Rated impulse strength U imp<br />

4 kV<br />

Outputs<br />

4 mono-/bistable outputs depending on the variant<br />

Auxiliary contacts of outputs<br />

3 outputs thereof are connected to a common potential <strong>and</strong> 1 is connected separately; can be freely assigned to the<br />

control functions (e.g. for activation of mains <strong>and</strong> star-delta contactor as well as signalling of the operating state)<br />

Upstream short-circuit protection for<br />

Fuse-links utilization category gL/gA 6 A, fast 10 A<br />

auxiliary contacts (outputs)<br />

Circuit-breaker 1.6 A, C characteristic<br />

Rated continuous current<br />

5 A<br />

17


Rated operating current<br />

(Switching capacity)<br />

Inputs<br />

AC-15; 6 A/24 V; 6 A/120 V; 3 A/230 V<br />

DC-13; 2 A/24 V; 0.55 A/60 V; 0.25 A/125 A<br />

4, own power supply due to device electronics (24 V DC); inputs connected to a common potential for the coupling<br />

of process signals such as e.g. local control station, key-operated switches or limit switches<br />

Thermistor motor protection<br />

Total cold resistance: 1.5 kO<br />

(PTC thermistor detector)<br />

Operating value: 2.7... 3.1 kO; release value: 1.5...1.65 kO<br />

Connection cross-section<br />

Torque<br />

0.8 to 1.2 Nm<br />

single-core <strong>and</strong> str<strong>and</strong>ed 1 x (0.5 to 4.0) mm 2 ; 2 x (0.5 to 2.5) mm 2<br />

flexible with/without conductor barrel 1 x (0.5 to 2.5) mm 2 ; 2 x (0.5 to 1.5) mm 2<br />

<strong>3UF5</strong>1 extension module<br />

<strong>System</strong> interface<br />

Auxiliary circuit/control circuit<br />

Rated insulation voltage U I 300 V (for pollution degree 3)<br />

Rated impulse strength U imp<br />

Outputs<br />

Auxiliary contacts of outputs<br />

Upstream short-circuit protection for<br />

auxiliary contacts (outputs)<br />

Rated continuous current<br />

Rated operating current<br />

(Switching capacity)<br />

Inputs<br />

RS232 as connection to the basic unit <strong>and</strong><br />

for connection of operating module, manual operating device or PC<br />

4 kV<br />

4 bistable outputs<br />

3 outputs thereof are connected to a common potential <strong>and</strong> 1 is connected separately;<br />

can be freely assigned to the control functions (e.g. for activation of mains <strong>and</strong> star-delta contactor as well as<br />

signalling of the operating state)<br />

Fuse-links utilization category gL/gA 6 A, fast 10 A<br />

Circuit-breaker 1.6 A, C characteristic<br />

5 A<br />

AC-15; 6 A/24 V; 6 A/120 V; 3 A/230 V<br />

DC-13; 2 A/24 V; 0.55 A/60 V; 0.25 A/125 A<br />

Connection cross-section<br />

Torque<br />

0.8 to 1.2 Nm<br />

single-core <strong>and</strong> str<strong>and</strong>ed 1 x (0.5 to 4.0) mm 2 ; 2 x (0.5 to 2.5) mm 2<br />

flexible with/without conductor barrel 1 x (0.5 to 2.5) mm 2 ; 2 x (0,5 to 1.5) mm 2<br />

<strong>3UF5</strong>2 operating module<br />

Displays<br />

green LED „Ready“<br />

8 externally supplied 24 V DC, 115 V AC, 230 V AC depending on the variant, inputs connected to a common potential<br />

for the coupling of process signals such as e.g. local control station, key-operated switches or limit switches<br />

Permanent light “Ready“<br />

OFF “no control supply voltage“ or “function test negative, device blocked“<br />

red LED „General Fault“<br />

Permanent light/flashing light “Branch fault“,␣␣e.g. overload tripping<br />

3 green und 3 yellow LEDs Feeder-specific displays can be freely assigned, e.g. manual/automatic mode,<br />

tripping, thermistor motor protection, clockwise/anti-clockwise rotation etc.<br />

Operating buttons<br />

Keys<br />

Test/Reset<br />

<strong>System</strong> interface<br />

For controlling the motor feeder, freely programmable<br />

By pressing the Test/Reset button the device can be reset after a trip<br />

or it can be tested as to its functionality<br />

RS232 for connection of manual operating device or PC<br />

3WX36 manual operating device<br />

Displays<br />

Keys<br />

Power supply<br />

2 lines, 16 letters.<br />

3 function keys, 4 cursor keys, 1 acknowledgement key<br />

4 batteries, type 1.5 V round cell<br />

18


Win-<strong>SIMOCODE</strong>-<strong>DP</strong>/Professional <strong>3UF5</strong>710<br />

Parameterization, Operate, Observe, Testing over <strong>DP</strong>V1<br />

Parameterization, Operate, Observe, Testing over RS-232<br />

Target system<br />

SIMATIC S5<br />

Automation <strong>System</strong><br />

SIMATIC S7/M7/C7/PCS7<br />

foreign system<br />

PC/PU requirements<br />

sea PC-/PU requirements Windows 95 or Windows NT ≥ 4.0<br />

free capacity harddisk<br />

minimum 10 MB<br />

STEP 7 requirements<br />

STEP 7 is not an absolute necessity. But when it is already installed it is necessary<br />

to have a Version ≥ 4.0. (These version contain the compatible support software for <strong>DP</strong>V1<br />

otherwise it will be directly loaded through Win-<strong>SIMOCODE</strong>-<strong>DP</strong>/Professional)<br />

PC/PU interface requirements<br />

PU integrated with MPI-SS or MPI-Board<br />

CP 5411, CP 5412 (A2), CP 5511 or CP 5611<br />

RS-232 with compatible interface cable 3RW29 20-1DA00<br />

<strong>SIMOCODE</strong>-<strong>DP</strong> requirements <strong>DP</strong>V1-delivery date E10 (from June 98)<br />

Win-<strong>SIMOCODE</strong>-<strong>DP</strong>/Smart <strong>3UF5</strong>711<br />

PC/PU requirements<br />

sea PC-/PU preconditions Windows 95 or Windows NT ≥ 4.0<br />

free capacity harddisc<br />

minimum 10 MB<br />

PC/PU interface requirements<br />

OM-<strong>SIMOCODE</strong>-<strong>DP</strong> <strong>3UF5</strong>712<br />

SIMATIC requirements<br />

RS-232 with compatible interface cable 3RW29 20-1DA00<br />

SIMATIC S7/M7/C7/PCS7<br />

STEP 7 requirements Version ≥ 4.0<br />

PC/PU requirements Software STEP 7<br />

<strong>SIMOCODE</strong>-<strong>DP</strong> requirements <strong>DP</strong>V1 – delivery date E10 (from June 98)<br />

19


www.ad.siemens.de<br />

Automation <strong>and</strong> Drives Group<br />

Low Voltage <strong>Control</strong>s <strong>and</strong> Distribution Division<br />

P.O. Box 32 40, D-91050 Erlangen<br />

Siemens Aktiengesellschaft<br />

Subject to change without prior notice 4/98<br />

Order No. E20001-A230-P302-X-7600<br />

Printed in Germany<br />

Dispostelle 27615/SEK 30197<br />

21C7128 CPSM.52.1.03 PS 07013.0