1. Specification<br />

MICOM<br />

Models<br />

Cooling Capacity<br />

kW<br />

Btu/h<br />

Heating Capacity<br />

kW<br />

Btu/h<br />

Power Input Cooling/Heating W<br />

Running Current Cooling/Heating A<br />

Starting Current Cooling/Heating A<br />

EER<br />

W/W<br />

Btu/h.W<br />

COP<br />

W/W<br />

Power Supply<br />

Ø / V / Hz<br />

Power Factor %<br />

<strong>Air</strong> Flow Rate<br />

Indoor,Max<br />

m 3 /min(cfm)<br />

Outdoor,Max<br />

m 3 /min(cfm)<br />

Moisture Removal<br />

l/h<br />

Sound Level Indoor,H/M/L dB(A)+3<br />

Outdoor,Max<br />

dB(A)+3<br />

Refrigerant & Charge<br />

g(oz)<br />

Type<br />

Model<br />

Compressor<br />

Motor Type<br />

Oil Type<br />

Oil Charge<br />

cc<br />

O.L.P Name<br />

Type(In/Out)<br />

Fan<br />

Motor Type<br />

Motor Output<br />

W<br />

Power Supply Cable No.*mm 2<br />

Dimension<br />

W*H*D<br />

mm<br />

inch<br />

Net Weight Indoor kg(lbs)<br />

Tool Code(Chassis)<br />

Temperature Control<br />

Energy Saver Switch<br />

Prefilter(washable/anti-fungus)<br />

Plasma Filter<br />

Steps, Fan/Cool/Heat<br />

<strong>Air</strong>flow Direction Control(up&down)<br />

<strong>Air</strong>flow Direction Control(left&right)<br />

Remocon Type<br />

Setting Temperature<br />

Cooling<br />

Functions Range Heating<br />

Auto Operation (Micom Control)<br />

Panel Touch Type<br />

Timer<br />

<strong>Air</strong> Discharge<br />

<strong>Air</strong> Ventilation<br />

Deice Control(Defrost)<br />

Hot Start<br />

Look<br />

Cabinet Type(Chassis Type)<br />

Special Function<br />

Note:<br />

O : Applied, - : No relation<br />

* For circuit breaker rating, please conform to local standards wherever necessary.<br />

❈ Some of functions are slightly different depending upon models.<br />

❈ The specification may be subject to change without notice for purpose of improvement.<br />

2 <strong>Window</strong> <strong>Air</strong> <strong>Conditioner</strong><br />

TWC096CBMK1<br />

2.56<br />

8735<br />

-<br />

-<br />

880<br />

3.9<br />

-/-<br />

2.91<br />

9.93<br />

-<br />

1 / 220~240 / 50<br />

94<br />

8.5(142)<br />

15(250)<br />

0.8<br />

47/-/-<br />

55<br />

R22, 355(12.5)<br />

Rotary(Non Tropical)<br />

PH150X1C-4DVDE3<br />

PSC<br />

SUNISO 4GSD<br />

400<br />

BF785-MH<br />

Propeller<br />

6 POLES<br />

108<br />

3*2.1<br />

660*428*770<br />

25.98*16.85*30.31<br />

56(123.5)<br />

WN<br />

Thermistor<br />

-<br />

O<br />

WASHABLE<br />

3/3<br />

manual<br />

manual<br />

-<br />

16°C~30°C<br />

-<br />

-<br />

Micom<br />

-<br />

Side by side<br />

O<br />

O<br />

-<br />

B-Look<br />

-<br />

-