TECHNICAL SPECIFICATIONS 15 EN<br />

Model<br />

Maximum noise and vibration levels<br />

<strong>MBCP254</strong><br />

Operator ear noise pressure level (EN ISO 22868)<br />

with line cutter head dB(A) 102<br />

Measurement uncertainty (2006/42/EC - EN 27574) dB(A) 3<br />

Measurement uncertainty (2006/42/EC - EN 12096) m/sec 2 1,5<br />

with 3-point blade<br />

dB(A) 95<br />

Measurement uncertainty (2006/42/EC - EN 27574) dB(A) 3<br />

Measured sound power level (EN ISO 22868)<br />

with line cutter head<br />

dB(A) 111<br />

Measurement uncertainty (2006/42/EC - EN 27574) dB(A) 3<br />

with 3-point blade<br />

dB(A) 105<br />

Measurement uncertainty (2006/42/EC - EN 27574) dB(A) 3<br />

Vibrations transmitted to the hand on the front handgrip (“MONO”) (ISO 22867)<br />

with line cutter head m/sec 2 –<br />

Measurement uncertainty (2006/42/EC - EN 12096) m/sec 2 –<br />

with 3-point blade m/sec 2 –<br />

Measurement uncertainty (2006/42/EC - EN 12096) m/sec 2 –<br />

Vibrations transmitted to the hand on the rear handgrip (“MONO”) (ISO 22867)<br />

with line cutter head m/sec 2 –<br />

Measurement uncertainty (2006/42/EC - EN 12096) m/sec 2<br />

–<br />

with 3-point blade m/sec 2 –<br />

Measurement uncertainty (2006/42/EC - EN 12096) m/sec 2 –<br />

Vibrations transmitted to the hand on the left handgrip (“DUPLEX”) (ISO 22867)<br />

with line cutter head m/sec 2 1,76<br />

Measurement uncertainty (2006/42/EC - EN 12096) m/sec 2 1,5<br />

with 3-point blade m/sec 2 0,432<br />

Measurement uncertainty (2006/42/EC - EN 12096) m/sec 2 1,5<br />

Vibrations transmitted to the hand on the right handgrip (“DUPLEX”) (ISO 22867)<br />

with line cutter head m/sec 2 3,19<br />

Measurement uncertainty (2006/42/EC - EN 12096) m/sec 2 1,5<br />

with 3-point blade m/sec 2 0,356