Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>Sunways</strong> SM 215M Solar Module<br />
Models<br />
Output classes<br />
SM 230M SM 230M SM 230M SM 230M SM 230M<br />
240 235 230 225 220<br />
Category<br />
Module size (length x width)<br />
Area<br />
Thickness including frame<br />
Weight<br />
monocrystalline<br />
1610 x 1060 mm<br />
1,71 m 2<br />
50 mm<br />
24 kg<br />
Electrical Data with STC<br />
Rated output P MPP<br />
MPP voltage<br />
MPP current<br />
Open-circuit voltage<br />
Short-circuit current<br />
240 W 235 W 230 W 225 W 220 W<br />
48,90 V 48,80 V 48,70 V 48,60 V 48,50 V<br />
4,91 A 4,82 A 4,73 A 4,63 A 4,54 A<br />
59,50 V 59,40 V 59,30 V 59,20 V 59,10 V<br />
5,20 A 5,15 A 5,10 A 5,08 A 5,07 A<br />
Other electrical parameters<br />
System voltage<br />
Temperature coefficient P MPP<br />
Temperature coefficient I SC<br />
Temperature coefficient U OC<br />
Limits<br />
Permissible module temperature<br />
Installation specifications<br />
Design<br />
Cells<br />
Cell dimensions<br />
Front<br />
Encapsulation<br />
Back<br />
Frame<br />
Connection<br />
Bypass diodes<br />
Qualifications and certificates<br />
1000 V<br />
-0,44 % / °C<br />
0,06 % / °C<br />
-0,36 % / °C<br />
-40 to +85 °C<br />
96 <strong>Sunways</strong> solar cells, monocrystalline<br />
125 x 125 mm, pseudo-square<br />
Solar glass, 4 mm, highly transparent<br />
EVA – Solar Cells – EVA<br />
PLF - polyester laminated film<br />
Aluminium, bright anodised<br />
2 x 1.2 m solar cables with Tyco Solarlok ® connectors<br />
4 pieces<br />
Protection class II, IEC 61215, CE<br />
50 mm<br />
STC Standard Test Conditions:<br />
Air mass AM 1.5<br />
Irradiation 1000 W/m 2<br />
Cell temperature 25 °C<br />
Reverse current loadability:<br />
Operation of the module using external<br />
current feed only permitted using<br />
phase/line fuse with tripping current<br />
< 3 x Isc(STC)<br />
34