ENTREE:Mise en page 1 - Switch made
ENTREE:Mise en page 1 - Switch made
ENTREE:Mise en page 1 - Switch made
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
ANSCHLUSSSCHEMA SCHÉMAS DE CÂBLAGE<br />
ALI05021<br />
L<br />
N<br />
Signal 1-10V<br />
+ -<br />
+<br />
-<br />
L<br />
L<br />
N<br />
1-10V<br />
Push<br />
PRI<br />
SEC<br />
+<br />
-<br />
1 2 3 4 5 6<br />
switch DIP<br />
red<br />
black/white<br />
black<br />
black<br />
+ -<br />
L 1<br />
MEGA III<br />
PANEOS 300x300<br />
ALI05021<br />
Signal 1-10V<br />
+ -<br />
+<br />
-<br />
L<br />
L<br />
N<br />
1-10V<br />
Push<br />
PRI<br />
ALI05021<br />
SEC<br />
+<br />
-<br />
1 2 3 4 5 6<br />
switch DIP<br />
black/white + -<br />
LED 1<br />
+<br />
black/white<br />
-<br />
black<br />
black<br />
PANEOS 600x600<br />
PANEOS 300x1200<br />
PANEOS 300x600<br />
PANEOS 300x900<br />
LED 2<br />
Signal 1-10V<br />
+ -<br />
+<br />
-<br />
L<br />
L<br />
N<br />
1-10V<br />
Push<br />
PRI<br />
ALI05021<br />
SEC<br />
+<br />
-<br />
1 2 3 4 5 6<br />
switch DIP<br />
black/white + -<br />
LED 1<br />
+<br />
black/white<br />
-<br />
black<br />
black<br />
PANEOS 600x1200<br />
LED 2<br />
+<br />
-<br />
L<br />
L<br />
N<br />
1-10V<br />
Push<br />
PRI<br />
SEC<br />
+<br />
-<br />
1 2 3 4 5 6<br />
switch DIP<br />
black/white + -<br />
LED 1<br />
+<br />
black/white<br />
black<br />
-<br />
black<br />
PANEOS 600x1200<br />
ALI05021<br />
LED 2<br />
SWITCH DIP CONFIG<br />
PRODUCT I.n. 6 5 4 3 2 1<br />
MAXIMUM<br />
SERIAL<br />
PANEOS 300X300 900MA ON ON ON - - - 1<br />
PANEOS 600X600 1400MA ON ON ON ON ON - 1<br />
PANEOS 300X1200 1400MA ON ON ON ON ON - 1<br />
PANEOS 600X1200 2X1400MA ON ON ON ON ON - 1<br />
PANEOS 300X900 1400MA ON ON ON ON ON - 1<br />
PANEOS 300X600 1400MA ON ON ON ON ON - 1<br />
MEGA 3 1050MA ON ON ON ON - - 1<br />
ACHTUNG :<br />
- Bevor Sie unter<br />
Spannung setz<strong>en</strong><br />
stell<strong>en</strong> Sie bitte sicher,<br />
dass der <strong>Switch</strong> DIP<br />
korrekt konfiguriert<br />
wurde.<br />
- Es besteht die<br />
Möglichkeit an Stelle<br />
des 1-10V Eingangs,<br />
d<strong>en</strong> L Push Eingang<br />
anzuschliess<strong>en</strong><br />
ATTENTION :<br />
- Avant de mettre sous<br />
t<strong>en</strong>sion, vérifer que le<br />
<strong>Switch</strong> DIP est<br />
correctem<strong>en</strong>t<br />
configuré.<br />
- possibilité de câbler<br />
l’<strong>en</strong>trée L Push, celle-ci<br />
remplacera l’<strong>en</strong>trée 1-<br />
10V<br />
SWITCH MADE<br />
TECHNISCHE BEILAGE CAHIER TECHNIQUE<br />
245