XXIX<br />
Wiring - Markings<br />
The unit is supplied with lampholder<br />
only<br />
As above but with lamp<br />
As above but wiring<br />
+ lamp + transformer<br />
CEL<br />
As CNR, with lamp and<br />
emergency kit<br />
The unit is supplied with<br />
lampholder and electronic<br />
ballast<br />
Fixtures with self-diagnosis<br />
circuitry with sub-code 0066<br />
available upon request.<br />
Class II fixture (double insulation).<br />
No grounding needed.<br />
IP...<br />
International Protection<br />
The IP prefix followed by two<br />
figures indicates the level<br />
of resistance of the fixture<br />
to penetration by solids<br />
and liquids. Protection rating<br />
(published in EN60529)<br />
parts<br />
With 230/12V transformer<br />
and lamp<br />
CELL<br />
As above, but with lamp<br />
F<br />
Fixtures installed on surfaces<br />
normally-fl ammable.<br />
IP20<br />
Protection against solid<br />
bodies Ø >12 mm only<br />
With 230/12V transformer<br />
and lamp + fuse<br />
With 230/12V transformer<br />
and lamp<br />
CEL-<br />
F<br />
CEL-<br />
E<br />
As CEL but with fuse<br />
As CEL, but with emergency<br />
kit<br />
V..<br />
V0: the test piece extinguishes<br />
within 5 sec. without<br />
dropping V2: the test piece<br />
extinguishes within 25 sec.<br />
(dropping allowed)<br />
Standard protective fuse<br />
IP23<br />
IP40<br />
Protection against solid<br />
bodies Ø >12 mm and rain<br />
Protection against solid<br />
bodies Ø > 1 mm only<br />
With 230/12V transformer<br />
+ lamp + fuse<br />
CELL-<br />
F<br />
As CELL, but with fuse<br />
Article complete with multiwatt<br />
ballast.<br />
IP43<br />
Protection against solid<br />
bodies Ø > 1 mm and rain<br />
The unit is supplied with lampholder,<br />
ballast, starter and<br />
wired ready to light<br />
CELF-<br />
E<br />
As CEL, but with fuse and<br />
emergency kit<br />
Article in ATEX version<br />
IP44<br />
Protection against solid<br />
bodies Ø > 1 mm and water<br />
sprays<br />
As above but with fuse<br />
CELLF-<br />
E<br />
As CELL, but with fuse and<br />
emergency kit<br />
IP50<br />
Protection against dust<br />
As above but with lamp<br />
CEL D<br />
The unit is supplied with dimming<br />
IP54<br />
Protection against dust and<br />
water sprays<br />
As CN, but with lamp<br />
+ fuse<br />
The unit is supplied with dimming<br />
+ lamp<br />
Protection against dust and<br />
water jets<br />
As CN, but with lamp and<br />
emergency Kit<br />
CEL<br />
DO<br />
The unit is supplied with<br />
Osram dimming<br />
Protection against dust and<br />
water sprays<br />
The unit is supplied with<br />
lampholder, ballast, starter<br />
and capacitor, wired ready<br />
to light<br />
As above, with fuse.<br />
fuse symbol<br />
The unit is supplied with<br />
Osram dimming + lamp<br />
Power supply with 230/240V<br />
-50/60Hz digital dimmable<br />
electronic ballast (DALI)<br />
Dust and water tight<br />
Dust and waterwave tight<br />
As CNR, with fuse and<br />
emergency kit<br />
As CNR, but with lamp<br />
As CNR, but with lamp and<br />
fuse<br />
As CNR but with emergency<br />
kit<br />
Lamp + emergency<br />
CELD-<br />
DIG-E<br />
CELLD<br />
-DIG<br />
CELFD<br />
-DIG<br />
CELLFD<br />
-DIG<br />
Power supply with 230/240V<br />
-50/60Hz digital dimmable<br />
electronic ballast (DALI) +<br />
emergency lighting<br />
Power supply with 230/240V<br />
-50/60Hz digital dimmable<br />
electronic ballast (DALI) +<br />
lamp<br />
Power supply with 230/240V<br />
-50/60Hz digital dimmable<br />
electronic ballast (DALI) +<br />
fuse<br />
Power supply with 230/240V<br />
-50/60Hz digital dimmable<br />
electronic ballast (DALI) +<br />
lamp and fuse<br />
Wiring for LED<br />
PROTECTION RATING AGAINST MECHANICAL IMPACT<br />
classification according to standard: EN 50102 o NF C 20-015<br />
Impact force NF C 20-010<br />
Third figure in our catalogue<br />
IK J IP<br />
00 0 0<br />
01 0,15 -<br />
02 0,20 1<br />
03 0,35 -<br />
04 0,50 3<br />
05 0,70 -<br />
06 1 -<br />
07 2 5<br />
08 5 -<br />
- 6 7<br />
09 10 -<br />