The X Scale<br />
Filter Windows<br />
• Use the Hanning Window for normal<br />
vibration monitoring (Frequency)<br />
• Use the Flat Top Window for calibration<br />
and accuracy (Amplitude)<br />
• Use the Uniform Window for bump<br />
testing and resonance checks (No<br />
Window)<br />
Jack D. Peters<br />
34