Argon Product Catalogue 2013 - Argon Medical Devices, Inc
Argon Product Catalogue 2013 - Argon Medical Devices, Inc
Argon Product Catalogue 2013 - Argon Medical Devices, Inc
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Disposable Pressure Transducer<br />
ical Care catalogue 2005 16/2/05 3:32 pm Page 16<br />
Pressure Transducer Sets<br />
Disposable Transducer Sets for the Invasive Monitoring of Haemodynamic Pressure<br />
BD Gabarith TM Disposable<br />
<strong>Argon</strong> Gabarith<br />
Transducer Sets<br />
TM Disposable<br />
Transducers Sets<br />
Sterile, single use<br />
Sterile, single use<br />
Disposable Transducer Sets for the Invasive Monitoring of Haemodynamic Pressure<br />
Number of Flush/Flow rate Total Pressure line(s) Additional Box/Case Item<br />
Disposable No. of disposable (cc/Hr)<br />
Transducers transducers<br />
Flush/Flow Pressure line<br />
Rate length cc/Hr (cm)<br />
Total colour Pressure<br />
Line Length<br />
Pressure Information Line(s)<br />
Colour<br />
ContentsAdditional<br />
Number<br />
(Units) Information<br />
Box/Case<br />
Content (Units)<br />
<strong>Product</strong><br />
Code<br />
1 3 150 Clear with R.O.S.E. 5/50 682001<br />
1 3 150cm Clear With <strong>Argon</strong> R.O.S.E. 5/50 682001<br />
1 3 150 Clear 5/50 682002<br />
1 1 3 3 150 Red 150cm Clear 5/50 682004<br />
5/50 682002<br />
1 3 150 Blue with R.O.S.E. 5/50 682005<br />
1<br />
1<br />
3<br />
3<br />
150 Blue<br />
150cm Red<br />
5/50 682006<br />
5/50 682004<br />
1<br />
1<br />
3<br />
3<br />
150 Yellow<br />
150cm<br />
Add-on set to set<br />
Blue<br />
no. 682037, -38, -55 5/50<br />
With <strong>Argon</strong> R.O.S.E.<br />
682008<br />
5/50 682005<br />
1 3 175 Red with R.O.S.E. 5/20 682009<br />
1 1 3 3 175 Red 150cm Blue 5/50 682010<br />
5/50 682006<br />
1 3 25 Clear Velcro strap for arm mount 5/50 682011<br />
1 3 150cm Yellow Add-on set to set no. 682037, -38, -55 5/50 682008<br />
1 3 150 Blue with Multiflo 5-way 5/50 68<strong>2013</strong><br />
1 1 3 3 150 Clear 175cm w/ non-shunting stopcock Red & extension set 5/25 With <strong>Argon</strong> R.O.S.E. 682017<br />
5/20 682009<br />
1 30 160 small bore Clear For use with infusion pump 5/50 682022<br />
1<br />
1<br />
30<br />
3<br />
35 small bore<br />
175cm<br />
Clear<br />
Red<br />
For use with infusion pump 5/50 682025<br />
5/50 682010<br />
2 1 3 3 150/150 Red/Blue 25cm with R.O.S.E. Clear on blue line Velcro 5/25strap for arm 682030 mount 5/50 682011<br />
2 3 150/150 Red/Blue 5/25 682032<br />
2 1 3 3 150/150 Red/Blue 150cm with 3rd IV line Blue for add-on set 5/25 With Multiflo TM 5-way 682037<br />
5/50 68<strong>2013</strong><br />
2 3 150/150 Blue/Yellow 5/25 682041<br />
1 3 150cm Clear With non-shunting stopcock and extension set 5/25 682017<br />
3 3 150/150/150 Red/Blue/Yellow 5/25 682046<br />
1 30 160cm small bore Clear For use with infusion pump 5/50 682022<br />
• Validation 1by unique Gabarith 30 accuracy test. 35cm small bore • BD Connecta Clear TM Plus sampling and zeroing For use stopcocks with infusion with pump 5/50 682025<br />
on/off snap for confirmation of stopcock positioning.<br />
• A range of 2 Single, Double and 3Triple Disposable Transducer<br />
150/150cm Red/Blue With <strong>Argon</strong> R.O.S.E. on blue line 5/25 682030<br />
Sets.<br />
• Designed straight fluid pathway minimises the risk of bubble<br />
2 3 150/150cm Red/Blue 5/25 682032<br />
entrapment and subsequent damping of signal.<br />
• Adult and Paediatric options.<br />
2 3 150/150cm Red/Blue With 3rd IV line for add-on set 5/25 682037<br />
• Robust monitor connection prevents water penetration and<br />
• BD Safedraw TM , closed loop arterial blood sampling system<br />
2 3 150/150cm offers back Blue/Yellow pressure calibration facility.<br />
5/25 682041<br />
available. (Please refer to next section).<br />
3 3 150/150/150cm • Unique Red/Blue/Yellow ‘Easy Vent’ zeroing deadender minimises risk of<br />
5/25 682046<br />
• R.O.S.E (Resonance OverShoot Eliminator) included in<br />
touch contamination.<br />
selected sets.<br />
Description<br />
• Wide range of transducer set configurations covering<br />
• Individually packed, sterile, non-pyrogenic and latex-free.<br />
• Validation by unique <strong>Argon</strong> Gabarith TM accuracy test neonatal to adult pressure • Robust monitoring monitor requirements. connection prevents water penetration and offers back<br />
• Adult A range pressure of Single, sets include Double rotating and male Triple luer Disposable for easy and Transducer Sets<br />
pressure calibration facility<br />
trouble-free connection onto the catheter.<br />
Sterilisation method:<br />
• Adult and Paediatric options.<br />
• Unique <strong>Argon</strong> EasyVent TM zeroing deadender minimises risk of touch<br />
• Ethylene oxide<br />
contamination<br />
How • <strong>Argon</strong> BD Gabarith Safedraw TM sets and can Safedraw-P benefit you<br />
TM closed loop arterial blood sampling<br />
system options available (please refer to next section)<br />
Shelf life:<br />
• Wide range of transducer set configurations covering neonatal to adult<br />
• Unique Gabarith testing of sets, using total<br />
• 5 years<br />
pressure monitoring requirements<br />
• haemodynamic <strong>Argon</strong> R.O.S.E. chain (Resonance concept, offers OverShoot the opportunity Eliminator) for included in<br />
selected sets<br />
improved haemodynamic accuracy 1 .<br />
Class IIa according to European Latex <strong>Medical</strong> free <strong>Devices</strong> Directive<br />
• Individually packed, sterile, non-pyrogenic and latex-free93/42/EEC<br />
• Adult pressure sets include rotating male luer for easy and trouble-free CE marked<br />
connection onto the catheter<br />
Class lla according to the European <strong>Medical</strong> <strong>Devices</strong><br />
1 Billiet E., Colardyn F. Pressure Measurement Evaluation & Accuracy Validation: The Gabarith Test. Intensive Care Medicine (1998) 24: 1323-1326<br />
How <strong>Argon</strong> Gabarith TM Sets can benefit you<br />
• Unique <strong>Argon</strong> Gabarith TM testing of sets, using total haemodynamic<br />
chain concept, offers the opportunity for improved haemodynamic<br />
accuracy 1 .<br />
• <strong>Argon</strong> sampling and zeroing stopcocks with on/off snap for<br />
confirmation of stopcock positioning<br />
• Designed straight fluid pathway minimises the risk of bubble<br />
entrapment and subsequent damping of signal<br />
Directive 93/42/EEC as amended by Directive 2007/47/EC<br />
Shelf life: 5 years<br />
Sterilisation method: Ethylene Oxide<br />
1 Billiet E., Colardyn F. Pressure Measurement Evaluation & Accuracy Validation: The Gabarith Test. Intensive Care Medicine (1998) 24: 1323-1326