LVM Catalog - Toshiba Industrial
LVM Catalog - Toshiba Industrial
LVM Catalog - Toshiba Industrial
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
LV General<br />
Purpose CT<br />
LV General<br />
Purpose XT<br />
LV Definite<br />
Purpose CT<br />
LV Definite<br />
Purpose XT<br />
Appendices Model No. Spare Production Stock MV General<br />
Index<br />
Parts Modifications Modifications Purpose XT<br />
238<br />
Appendix A<br />
<br />
First Field Second Field - HP Third Field - Poles & Fan Type Fourth Field - Construction<br />
Fifth Field<br />
(One Digit) (Three Digits) (One Digit)<br />
(One Digit)<br />
(One Digit)<br />
Symbol Phase/Start Design Symbol Output (HP) Symbol Pole Fan Type Symbol Enclosure Symbol Ins. S.F.<br />
A A X ? ? Reciprocal 1 Uni-CW A Open A 1<br />
B<br />
Three-Phase Squirrel Cage<br />
B X 1 2 1/12 2 2 Bi C Underwater Type - Gas Filled B 1.15<br />
C C X 2 0 1/20 3 Uni-CCW D Open Drip Proof Guarded C<br />
A<br />
1.25<br />
D D 4<br />
4<br />
Bi E Totally Enclosed D 1.35<br />
I (Note 8) Explosion Proof Drive System (UL File E53559)<br />
1 / 8 1/8 5 Uni F Totally Enclosed Fan Cooled E 1.4<br />
1 / 2 1/2 6<br />
6<br />
Bi G Weather Protected Type-1 U SPL<br />
L L 3 / 4 3/4 7 Uni K Open Pipe Ventilated F 1<br />
M<br />
Single-Phase Condensor SKD<br />
M 8<br />
8<br />
Bi M Splash Proof - Open Machine G 1.15<br />
N N 0 0 1 1 E Uni N Weather Protected Type-2 H<br />
B<br />
1.25<br />
O O 0 2 0 20 9<br />
10<br />
Bi O I 1.35<br />
P L 1 5 0 150 F Uni<br />
P Totally Enclosed Pipe-Ventilated Machine<br />
J 1.4<br />
Q<br />
Single-Phase Squirrel Cage SIK<br />
M A<br />
12<br />
Bi V SPL<br />
R N Y ? ? 1/10 Times G Uni Q Underwater Type - Oil Filled K 1<br />
S O Y 1 5 1 1/2 B<br />
14<br />
Bi S Guarded - Open Machine L 1.15<br />
T L Y 7 5 7 1/2 H Uni U Underwater Type - Water-Filled M 1.25<br />
F<br />
U Single-Phase, Two-Condensor Start & M 018 (Note 4) 18.5 kW C Bi V Dripproof N 1.35<br />
16<br />
V Operate SIKD<br />
N J Uni Y Explosion Proof O 1.4<br />
W O D<br />
18<br />
Bi R Corrosion Proof W SPL<br />
E<br />
Three-Phase Wound Rotor<br />
K Uni W Totally Enclosed Fan Cooled - Outdoor Use P 1.0<br />
M<br />
Over 20<br />
Bi Z Water-Proof Machine Q 1.15<br />
F Other Three-Phase N Uni B Totally Enclosed Air Over (TEAO) R<br />
H<br />
1.25<br />
W One Winding<br />
H Open Drip Proof Air Over S 1.35<br />
G Single-Phase, One Condensor SIKD<br />
X Two Winding<br />
L Liquid Cooling T 1.4<br />
Y Three Winding<br />
I Water Cooling X SPL<br />
X<br />
Single-Phase Shaded Pole<br />
Z<br />
Other<br />
J<br />
Bi = Bidirectional *<br />
*<br />
Uni = Unidirectional<br />
T Totally Enclosed with Water Air Cooled (TEWAC)<br />
Y<br />
Other Single-Phase<br />
*Viewed from OPE<br />
X Other<br />
Z IEC Metric 2 Brake Motor: 6 lb. ft.<br />
Use the Below for Motors over 1000 HP<br />
3 Brake Motor: 10 lb. ft.<br />
H Three-Phase Wound Rotor: Times 10<br />
4 Brake Motor: 15 lb. ft.<br />
J Three-Phase Squirrel Cage: Times 10<br />
5 Brake Motor: 35 lb. ft.<br />
K Three-Phase Squirrel Cage: Times 100<br />
6 Brake Motor: 50 lb. ft.<br />
Example(s):<br />
H125 = 1,250 HP<br />
K125 = 12,500 HP<br />
Single Speed<br />
Multi-Speed