23.12.2014 Views

Orthopaedic Procedure Electrosurgical System (OPES™)

Orthopaedic Procedure Electrosurgical System (OPES™)

Orthopaedic Procedure Electrosurgical System (OPES™)

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

AR-9602M-45<br />

AR-9602M-90<br />

AR-9608<br />

AR-9608-45<br />

AR-9603-30<br />

AR-9603-60<br />

AR-9603-90<br />

AR-9604-90<br />

AR-9703-60<br />

AR-9703-90<br />

AR-9704-60<br />

AR-9704-90<br />

AR-9705-60<br />

AR-9604A-90<br />

AR-9601SJ-90<br />

Arthroscopic Tissue<br />

Ablation and Coagulation<br />

Monopolar Ablation Probes and Ball Electrodes<br />

With the comprehensive line of tissue ablation probes, the possibilities are endless.<br />

The raised ribbed geometry of the ablation probe tips provide the most efficient design for<br />

effective ablating while providing the tactile feel required by surgeons. The high quality<br />

ceramic and insulation, as well as a stiffer shaft, make these probes extremely durable and<br />

reliable.<br />

The all-in-one handle, probe and cord design is an effective way to control “replacement<br />

costs” associated with other expensive, reusable components. The OPES assortment<br />

includes a number<br />

of tissue ablation/coagulation probes in aspirating and nonaspirating configurations.<br />

The line of low profile probes is designed to fit through smaller diameter cannulas<br />

typically used in shoulder procedures. The suction port is positioned through the active<br />

electrode face for optimum visualization and ablation efficiency as tissue is drawn toward<br />

the active electrode.<br />

The varying angled tips, electrode sizes and 130 mm shaft lengths offer the greatest<br />

number of choices resulting in optimal ablation control for procedure-specific use. All<br />

ablation probes may be used with hand or foot control, based on surgeon preference. With<br />

the foot control engaged, the hand control buttons become inactive for patient safety.<br />

Non-Aspirating Ablation Probes<br />

OPES Ablator, Meniscectomy, 45º<br />

OPES Ablator, Meniscectomy, 90º<br />

OPES Ball Electrode, Arthroscopic<br />

OPES Ablator, 3 mm, 30º<br />

OPES Ablator, 3 mm, 60º<br />

OPES Ablator, 3 mm, 90º<br />

OPES Ablator, 4 mm, 90º<br />

OPES Ablator, 3 mm, 60º, low profile<br />

OPES Ablator, 3 mm, 90º, low profile<br />

OPES Ablator, 4 mm, 60º, low profile<br />

OPES Ablator, 4 mm, 90º, low profile<br />

OPES Ablator, Toothbrush, 60º, low profile<br />

OPES Ablator, Toothbrush, 90º, low profile<br />

AR-9602M-45<br />

AR-9602M-90<br />

AR-9608<br />

AR-9603-30<br />

AR-9603-60<br />

AR-9603-90<br />

AR-9604-90<br />

AR-9703-60<br />

AR-9703-90<br />

AR-9704-60<br />

AR-9704-90<br />

AR-9705-60<br />

AR-9705-90<br />

AR-9705-90<br />

AR-9703A-60<br />

AR-9703A-90<br />

Aspirating Ablation Probes<br />

OPES Aspirating Ablator, 3 mm, 60º, low profile<br />

OPES Aspirating Ablator, 3 mm, 90º, low profile<br />

OPES Aspirating Ablator, 4 mm, 60º, low profile<br />

OPES Aspirating Ablator, 4 mm, 90º, low profile<br />

OPES Aspirating Ablator, Toothbrush, 60º, low profile<br />

OPES Aspirating Ablator, Toothbrush, 90º, low profile<br />

AR-9703A-60<br />

AR-9703A-90<br />

AR-9704A-60<br />

AR-9704A-90<br />

AR-9705A-60<br />

AR-9705A-90<br />

AR-9704A-60<br />

AR-9704A-90<br />

AR-9705A-60<br />

AR-9705A-90<br />

AR-9601SJ-45<br />

AR-9601SJ-90<br />

AR-9608SJ<br />

AR-9608SJ-45<br />

Monopolar Small Joint Ablation Probes and Ball Electrode<br />

The OPES Small Joint Ablation Probes and Ball Electrode provide controlled ablation,<br />

coagulation and tissue modification during arthroscopic procedures of the elbow, wrist<br />

and ankle. The 6.25 cm length probes have a 1.5 mm diameter active electrode in both 45<br />

and 90 degree tip angles. The optimal size provides superior visualization, manipulation<br />

and access to smaller joint spaces. The Ball Electrode tip is 2 mm and is malleable for<br />

intraoperative adjustments to assist in reaching tight areas. The small joint probes also<br />

function with hand or foot control.<br />

Small Joint Ablation Probes and Ball Probe<br />

OPES Ablator, Small Joint, 45º<br />

OPES Ablator, Small Joint, 90º<br />

OPES Ball Electrode, Small Joint<br />

AR-9601SJ-45<br />

AR-9601SJ-90<br />

AR-9608SJ

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!