43<br />

Air Infiltration Test Pressure<br />

In reference to the chart on the previous slide, all operator types in the R,<br />

LC <strong>and</strong> CW classes are tested at 1.6 psf. This is the approximate pressure<br />

generated by a 25 mph wind.<br />

All AW class windows are tested for air infiltration at 6.2 psf, the<br />

approximate pressure generated by a 50 mph wind.<br />

All air infiltration tests are per ASTM E 283.<br />

There are two parameters for air infiltration testing:<br />

1) Test pressure<br />

2) Maximum allowed air leakage