testing and validation of a new building energy simulation ... - ibpsa
testing and validation of a new building energy simulation ... - ibpsa
testing and validation of a new building energy simulation ... - ibpsa
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Annual Cooling (MWH)<br />
8.0<br />
7.0<br />
6.0<br />
5.0<br />
4.0<br />
3.0<br />
2.0<br />
1.0<br />
0.0<br />
600<br />
South Windows<br />
610<br />
S. Windows +<br />
Overhang<br />
620<br />
East & West<br />
Windows<br />
630<br />
E&W Windows +<br />
Overhang & Fins<br />
640<br />
Case 600 with H/C<br />
Temp. Setback<br />
Ver 1-23b<br />
Ver 1-23<br />
Ver 1-19<br />
Ver 1-17<br />
Ver 1-14<br />
Ver 1-11<br />
Ver 1-10<br />
Ver 1-09<br />
Ver 1-08<br />
Ver 1-05<br />
Beta 5-18<br />
Beta 5-09<br />
Beta 5-07<br />
Beta 5-06<br />
Beta 5-03<br />
Beta 4-16<br />
Beta 3-16<br />
Beta 2-18<br />
Beta 1-016<br />
BESTEST Case<br />
Figure 5 Comparison <strong>of</strong> Results for Various Versions <strong>of</strong> EnergyPlus for BESTEST/ASHRAE Std 140 –<br />
Low Mass Building Annual Cooling. Notice for Case 630 that annual cooling was reduced significantly when<br />
the fin shading coordinate problem was corrected in version 1-14.<br />
HVAC BESTEST Comparison<br />
Space Cooling Electricity Consumption<br />
(includes Compressor + OD Fan + ID Fan)<br />
1,800<br />
Electricity Use (kWh)<br />
1,600<br />
1,400<br />
1,200<br />
1,000<br />
800<br />
600<br />
400<br />
200<br />
CASIS/EDF<br />
CLIM2000/EDF<br />
DOE21E/CIEMAT<br />
DOE21E/NREL<br />
PROKST/KST<br />
TRNSYS-ideal/TUD<br />
TRNYS-real/TUD<br />
Analytical/TUD<br />
Analytical/HTAL1<br />
Analytical/HTAL2<br />
EnergyPlus Ver 1-23<br />
0<br />
E100<br />
Dry Coil<br />
Mid EDB<br />
High ODB<br />
High PLR<br />
E110<br />
Dry Coil<br />
Mid EDB<br />
Low ODB<br />
High PLR<br />
E140<br />
Dry Coil<br />
Mid EDB<br />
Low ODB<br />
Low PLR<br />
E150<br />
Wet Coil<br />
Mid EDB<br />
Low ODB<br />
High PLR<br />
High SHR<br />
E160<br />
Wet Coil<br />
High EDB<br />
Low ODB<br />
High PLR<br />
High SHR<br />
HVAC BESTEST Case<br />
E180<br />
Wet Coil<br />
Mid EDB<br />
Low ODB<br />
High PLR<br />
Low SHR<br />
E185<br />
Wet Coil<br />
Mid EDB<br />
High ODB<br />
High PLR<br />
Low SHR<br />
E190<br />
Wet Coil<br />
Mid EDB<br />
Low ODB<br />
Low PLR<br />
Low SHR<br />
EnergyPlus Version 1.0 Build 023<br />
Figure 6 Electricity Consumption Results for Selected HVAC BESTEST Cases. EnergyPlus results are<br />
within the range <strong>of</strong> results from the other tested programs, but there are some issues related to fan <strong>energy</strong> <strong>and</strong><br />
humidity ratio which warrant further investigation.<br />
- 357 -