2 | <strong>P1224</strong> <strong>Series</strong> Wall‐mount Field‐selectable <strong>Horn</strong> <strong>Strobes</strong><br />

When used in applications requiring the appliance to be<br />

weather‐proof or outdoor listed, the <strong>P1224</strong>MCK model<br />

must be used. It must be installed to the SSWBB<br />

Weatherproof Back Box using the supplied mounting plate<br />

and gasket.<br />

Indoor Applications<br />

These horn strobes are equipped with a mounting plate that<br />

can be mounted to the indicated back boxes for the<br />

indicated applications:<br />

Conduit<br />

Applications<br />

Surface<br />

Mounted<br />

Flush<br />

Mounted<br />

Single‐gang • 1<br />

four‐inch square • • 2 •<br />

1 Flush mounting on a single‐gang box requires using an<br />

SSS‐MP Small Footprint Mounting Plate.<br />

2 Surface mounting on a four‐inch square back box requires<br />

the use of a surface mount back box skirt (SSBBS or<br />

SSBBSW).<br />

Strobe Cautions<br />

Do not exceed:<br />

• The voltage range for the chosen nominal voltage (8 V<br />

to 17.5 V for 12 V nominal or 16 V to 33 V for 24 V<br />

nominal)<br />

• 70 strobes and a maximum line impedance of 4 Ω per<br />

loop when using a synchronization module<br />

• The maximum line impedance of the control panel<br />

Wiring<br />

Note<br />

These strobe units are not recommended for<br />

use in coded or pulsed signaling circuits.<br />

The input terminals accept wires with diameters between<br />

18 AWG (1.2 mm) and 12 AWG (2.3 mm).<br />

Parts Included<br />

Quant.<br />

Component<br />

1 <strong>P1224</strong> <strong>Horn</strong> Strobe<br />

1 SSD‐MP Universal Mounting Plate<br />

1 Hardware pack<br />

1 Literature pack<br />

Technical Specifications<br />

Environmental Considerations<br />

Mechanical Properties<br />

Candela Selections: 15 cd 1 , 15/75 cd 1 , 30 cd 2 , 75 cd 2 ,<br />

or 110 cd 2<br />

Dimensions (HxWxD)<br />

with universal plate:<br />

Dimensions (HxWxD)<br />

with small footprint plate:<br />

<strong>Horn</strong> Audibility<br />

(UL Reverberant Room)<br />

at 10 ft (3 m):<br />

Material:<br />

Weight without mounting plate:<br />

5.6 in. x 5 in. x 2.9 in.<br />

(14.3 cm x 12.7 cm x 7.5 cm)<br />

5.6 in. x 3.4 in. x 2.3 in.<br />

(14.3 cm x 8.6 cm x 5.9 cm)<br />

75 dBA<br />

Molded plastic enclosure incorporating<br />

a Xenon flashtube.<br />

8.8 oz. (0.25 kg)<br />

1 When set at these settings (15 cd or 15/75 cd) the devices<br />

automatically work on both 12 V and 24 V power supplies.<br />

The 15/75 cd selection is listed at 15 cd per UL1971 but<br />

provides 75 cd on axis.<br />

2 The strobe is not listed for 12 V operating voltages when<br />

set to these selections (30 cd, 75 cd, and 110 cd). When<br />

using a 12 V control panel, this device yields required light<br />

output only in the 15 cd and 15/75 cd settings.<br />

Power Requirements<br />

Maximum Operating <strong>Horn</strong> Current<br />

(12 VDC):<br />

Maximum Operating <strong>Horn</strong> Current<br />

(12 VFWR):<br />

Maximum Operating <strong>Horn</strong> Current<br />

(24 VDC):<br />

Maximum Operating <strong>Horn</strong> Current<br />

(24 VFWR):<br />

Maximum Operating Strobe Current<br />

(12 VDC):<br />

Maximum Operating Strobe Current<br />

(12 VFWR):<br />

Maximum Operating Strobe Current<br />

(24 VDC):<br />

Maximum Operating Strobe Current<br />

(24 VFWR):<br />

Voltage (Nominal Input):<br />

57 mA RMS<br />

57.58 mA RMS<br />

44.4 mA RMS<br />

45.7 mA RMS<br />

15 cd: 127 mA RMS<br />

15/75 cd: 27 mA RMS<br />

15 cd: 112 mA RMS<br />

15/75 cd: 135 mA RMS<br />

15 cd: 59 mA RMS<br />

15/75 cd: 9 mA RMS<br />

30 cd: 90 mA RMS<br />

75 cd: 160 mA RMS<br />

110 cd: 209 mA RMS<br />

15 cd: 64 mA RMS<br />

15/75 cd: 4 mA RMS<br />

30 cd: 93 mA RMS<br />

110 cd: 08 mA RMS<br />

12 VDC or FWR unfiltered or<br />

24 VDC or FWR unfiltered<br />

Voltage (Operating Range): 12 V: 9.5 V to 17.5 V;<br />

24 V: 16 V to 33 V<br />

Relative Humidity:<br />

Temperature (operating):<br />

Up to 95%, non‐condensing<br />

Indoor use: +32°F to +120°F<br />

(0°C to +49°C)<br />

Outdoor use: +32°F to +150°F<br />

(0°C to +66°C)<br />

Trademarks<br />

QuickClick and Sync•Circuit are trademarks of System Sensor® in the<br />

United States and other countries.<br />

System Sensor® is a registered trademark or a trademark of Pittway International,<br />

Ltd. in the United States and other countries.