Valve connection<br />

XV124<br />

7XV124.50-11/12<br />

7XV108.50-51<br />

7XV124.50-61/62<br />

Short description 7XV124.50-11 7XV124.50-12 7XV124.50-51 7XV124.50-61 7XV124.50-62<br />

Remote valve manifold connection for 25-pin DSUB 24 valves 24 valves 24 valves 24 valves 24 valves<br />

multi-pin connection, X2X Link, electrically isolated,<br />

24xDO 0.1 A, 24 VDC, separate 24 VDC supply<br />

Outputs 7XV124.50-11 7XV124.50-12 7XV124.50-51 7XV124.50-61 7XV124.50-62<br />

Rated voltage 24 VDC 24 VDC 24 VDC 24 VDC 24 VDC<br />

Max. output current 0.1 A 0.1 A 0.1 A 0.1 A 0.1 A<br />

Output circuit Source Source Source Source Source<br />

Max. switching frequency 100 Hz 100 Hz 100 Hz 100 Hz 100 Hz<br />

Max. switching frequency 200 s 200 s 200 s 200 s 200 s<br />

Max. switching frequency 250 s 250 s 250 s 250 s 250 s<br />

Output protection<br />

Protected against short circuit,<br />

overload and overtemperature<br />

Protected against short circuit,<br />

overload and overtemperature<br />

Protected against short circuit,<br />

overload and overtemperature<br />

Protected against short circuit,<br />

overload and overtemperature<br />

Protected against short circuit,<br />

overload and overtemperature<br />

General information 7XV124.50-11 7XV124.50-12 7XV124.50-51 7XV124.50-61 7XV124.50-62<br />

Status indicators Operating status and supply Operating status and supply Operating status and supply Operating status and supply Operating status and supply<br />

Electrical isolation<br />

X2X Link - Digital outputs Yes Yes Yes Yes Yes<br />

X2X Link – 24 VDC X2X, OUT supply Yes Yes Yes Yes Yes<br />

Digital outputs - 24 VDC X2X, OUT supply No No No No No<br />

Power consumption Max. 1.5 W Max. 1.5 W Max. 1.5 W Max. 1.5 W Max. 1.5 W<br />

Certification CE, C-UL-US CE, C-UL-US CE, C-UL-US CE, C-UL-US CE, C-UL-US<br />

Ex zone 2<br />

II 3G EEx nA II T5, IP67,<br />

Ta = 0 - 50°C<br />

II 3G EEx nA II T5, IP67,<br />

a = 0 - 50°C<br />

II 3G EEx nA II T5, IP67,<br />

a = 0 - 50°C<br />

Wiring 7XV124.50-11 7XV124.50-12 7XV124.50-51 7XV124.50-61 7XV124.50-62<br />

GND pin 25 13 25 25 13<br />

Bus connection 11-pin 11-pin M12 M12 M12<br />

Power supply Bus connection Bus connection M8 M8 M8<br />

Mechanical characteristics 7XV124.50-11 7XV124.50-12 7XV124.50-51 7XV124.50-61 7XV124.50-62<br />

Protection type IP20 IP20 IP67 IP67 IP67<br />

Operating temperature 0°C to 55°C 0°C to 55°C 0°C to 55°C<br />

(in non-Ex environments)<br />

0°C to 55°C<br />

(in non-Ex environments)<br />

0°C to 55°C<br />

(in non-Ex environments)<br />

Relative humidity 5 to 95%, non-condensing 5 to 95%, non-condensing 5 to 95%, non-condensing 5 to 95%, non-condensing 5 to 95%, non-condensing<br />

Module dimensions including mounting plates 63 x 59 x 20 mm (H x W x D) 63 x 59 x 20 mm (H x W x D) 62 x 70 x30 mm (H x W x D) 67 x 66 x30 mm (H x W x D) 67 x 66 x30 mm (H x W x D)<br />

Required accessories<br />

0TB1111.8110 Accessory terminal block (3.5), 11-pin, cage clamps, 1.5 mm², protected against vibration by the screw flange 2 686<br />