02.01.2015 Views

1 - Frames Data

1 - Frames Data

1 - Frames Data

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

To learn more information about these products, visit our website @ www.bernell.com<br />

VV1000HGT $ 4190.00 (With Glare Attachment ­ Pictured Left)<br />

VV1000WG $2795.00<br />

VECTORVISION CONTRAST SENSITIVITY TESTING UNIT<br />

(Without Glare Attachment)<br />

The VV­1000 is used clinically by eye doctors in over 45 countries to evaluate cataracts, glaucoma, diabetic eye disease,<br />

contact lens performance, refractive surgery, etc. In addition, the instrument has been selected for use in<br />

numerous multi­center trials for the evaluation of contrast sensitivity, ETDRS acuity, low contrast acuity and glare<br />

sensitivity. These studies include those for PRK refractive surgery, contact lens evaluation, LASIK refractive surgery,<br />

athlete visual performance, visual impact of pharmaceutical treatments, etc.<br />

The VV­1000 is the only self­standardized vision testing instrument. In each row of the device, photocell circuitry continually monitors and calibrates the<br />

instrument light level. This unique system senses both the external light striking the face of the instrument and the internal light which emanates from<br />

the miniature fluorescent bulbs. The patented VV­1000 standardization insures that testing light levels do not vary due to changes in line voltage or due<br />

to bulb aging. No other vision testing instrument offers this standardization package. The unit is operated by wireless remote control so that each row of<br />

the instrument can be individually lighted for easier viewing by the patient. The unit can easily rest on a table, hang on the wall or be used with rolling<br />

floor stand. The instrument can be easily transported from office to office or to out­of­office screening locations.<br />

HAMILTON­VEALE CONTRAST SENSITIVITY TEST<br />

HVCST $77.95<br />

This easy and convenient test can be used to monitor a decrease on the contrast sensitivity function over time.<br />

This test also demonstrates the difficulty of seeing in poor lighting or at night. Conditions affecting Contrast<br />

Sensitivity include: Age, Glaucoma, Cataract, IOL, Keratomas, Diabetes, Macular edema, Optic neuritis, MS,<br />

Parkinsons, Papilloedema. Made of washable material.<br />

Rules of thumb with this test:<br />

Level 4 or Less: Suffer from severe loss or are legally blind<br />

Level 5­8: Suffer significant loss and need contrast enhancement<br />

Level 9­12: Have noticeable loss and need lighting evaluation<br />

Level 13­16: Have a near normal contrast sensitivity<br />

Pay as it earns: VV1000WG<br />

$495 + tax(if any) down<br />

$102.98/mo 24 mo. $171.52 interest<br />

EXAM ROOM NEEDS<br />

PATTI PICS NEAR CHARTS<br />

HANKS PEDIATRIC TEST CARDS<br />

AUPTC $134.95<br />

LEA PUZZLE<br />

FRONT<br />

GF1600 $49.95<br />

BACK<br />

Chart has a cord attached that helps set the correct viewing distance.<br />

Measures acuity of 20 / 400 to 20 / 10 on front. MassVat Bars on back with<br />

20/ 100 to 20/ 16 help the patient’s concentration on each line. Also, the<br />

design of the MassVat rectangle provides adequate contour interaction.<br />

Helps detect amblyopia and other foveal problems. 8” x 10”<br />

Includes same response cards as USO2501.<br />

USO2508 $25.95 (NEAR CHART­­16IN)<br />

The LEA Puzzle is designed for training and<br />

assessing typically developing toddlers and<br />

other young children. The puzzle also<br />

serves as an assessment tool for individuals<br />

with brain damage, or for older children and adults with low cognitive abilities.<br />

The goal in the play training of toddlers and young children is to help<br />

them develop the concept of same/different as a prerequisite for early<br />

measurement of visual acuity. Includes instructions and the booklet:<br />

Assessing Vision Development Through Pictures and Shapes. Tray is 6.75" x<br />

6.75". The 4 symbol puzzle pieces are approximately 2" x 2" each.<br />

Collection of 66 test cards for use<br />

during examination of children.<br />

Hanks Paediatric Optotypes ­<br />

Calibrated from 6 / 60 to 6 / 4.<br />

Designed for this purpose and tested<br />

in clinical trials to confirm<br />

recognition of the symbols by<br />

young children. Landolt C &<br />

Illiterate E Optotypes are also<br />

included ­ Calibrated from 6 / 60<br />

to 6 / 4. Color Vision Screening ­<br />

Pseudo­isochromatic plates with letters, numbers, circles and trails.<br />

Quality Production ­ Each card is matt laminated and encapsulated<br />

for long life protection. Actual size of each card is 108 x 112mm.<br />

HANKS NEAR READING CHARTS<br />

Popular A4 laminated near­point<br />

charts for both adults and children.<br />

Range of print sizes with visual acuity<br />

notations in Snellen, Jaeger, Decimal,<br />

etc. Also shows indicated magnifications<br />

& reading ages. Includes a wide<br />

range of contemporary near tasks:<br />

Music, computer, phone book,<br />

newsprint, share listing, classifieds,<br />

textbook, etc.<br />

AUNRC $15.25<br />

LEA AMBLYOPIA SCREENING<br />

The gray background reduces dazzle in<br />

photophobic children. The test lines are<br />

wider apart to reduce crowding in the<br />

near test and only one line shows at a<br />

time in the distant test. There are two<br />

copies of each line in the distance test.<br />

Come with four flash cards.<br />

GF259900 $ 44.95 Distance test<br />

GF252000<br />

$ 26.95<br />

Near test<br />

GF251000<br />

$27.25<br />

LEA SYMBOLS/NUMBERS<br />

One side has LEA Symbols ® line test and<br />

the other has LEA Numbers ® test.<br />

Proportionally­spaced lines from sizes<br />

20/400 to 20/10 (6/120 to 6/3).<br />

Attached cord ensures proper testing<br />

distance of 40 cm. Response key printed<br />

on test card.Flash cards and instructions<br />

included. 8" x 10" (20.3 cm x 25.4 cm)<br />

FAX ORDERS TO SAVE TIME & MONEY AT (574)259­2102 OR 2103 OR GO TO www.bernell.com<br />

27

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!