Parametric Study of Front-End Nuclear Fuel Cycle Costs Using ...
Parametric Study of Front-End Nuclear Fuel Cycle Costs Using ...
Parametric Study of Front-End Nuclear Fuel Cycle Costs Using ...
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
LIST OF FIGURES<br />
Figure 3-1 Comparison <strong>of</strong> <strong>Front</strong>-<strong>End</strong> <strong>Fuel</strong> <strong>Cycle</strong> Cost for NatU and RepU LWR <strong>Fuel</strong> as a<br />
Function <strong>of</strong> U 3<br />
O 8<br />
Unit <strong>Costs</strong> ............................................................................................... 3-2<br />
Figure 3-2 Comparison <strong>of</strong> <strong>Front</strong>-<strong>End</strong> <strong>Fuel</strong> <strong>Cycle</strong> Cost for NatU LWR <strong>Fuel</strong> and RepU<br />
LWR <strong>Fuel</strong> as a Function <strong>of</strong> Changes to Unit <strong>Costs</strong> <strong>of</strong> Enrichment Services ...................... 3-4<br />
Figure 3-3 Comparison <strong>of</strong> Impact <strong>of</strong> Changing Fabrication Services <strong>Costs</strong> on Overall<br />
<strong>Front</strong>-<strong>End</strong> <strong>Fuel</strong> <strong>Cycle</strong> <strong>Costs</strong> for NatU and RepU LWR <strong>Fuel</strong> ............................................... 3-6<br />
Figure 3-4 Comparison <strong>of</strong> <strong>Front</strong>-<strong>End</strong> <strong>Fuel</strong> <strong>Cycle</strong> Cost for NatU LWR <strong>Fuel</strong> and RepU<br />
LWR <strong>Fuel</strong> as a Function <strong>of</strong> Enrichment Tails Assay .......................................................... 3-7<br />
Figure 3-5 Comparison <strong>of</strong> <strong>Front</strong>-<strong>End</strong> <strong>Fuel</strong> <strong>Cycle</strong> Cost for NatU LWR <strong>Fuel</strong> and RepU<br />
LWR <strong>Fuel</strong> as a Function <strong>of</strong> Natural Uranium Unit Cost and RepU Value .......................... 3-8<br />
Figure 3-6 Comparison <strong>of</strong> <strong>Front</strong>-<strong>End</strong> <strong>Fuel</strong> <strong>Cycle</strong> Cost for NatU LWR <strong>Fuel</strong> and RepU<br />
LWR <strong>Fuel</strong> as a Function <strong>of</strong> Natural Uranium Unit Cost and RepU Initial Enrichment ........ 3-9<br />
Figure 3-7 Comparison <strong>of</strong> <strong>Front</strong>-<strong>End</strong> <strong>Fuel</strong> <strong>Cycle</strong> Cost for NatU LWR <strong>Fuel</strong> and RepU<br />
LWR <strong>Fuel</strong> as a Function <strong>of</strong> Conversion and Enrichment Services Unit <strong>Costs</strong> ................. 3-11<br />
Figure 3-8 Comparison <strong>of</strong> <strong>Front</strong>-<strong>End</strong> <strong>Fuel</strong> <strong>Cycle</strong> Cost for NatU LWR <strong>Fuel</strong> and RepU<br />
LWR <strong>Fuel</strong> as a Function <strong>of</strong> Uranium Ore Concentrate and Enrichment Services Unit<br />
<strong>Costs</strong> ................................................................................................................................ 3-13<br />
ix