Error Requirements <strong>for</strong> CC <strong>MERIS</strong> Data (II)<br />

Parameters<br />

Units<br />

Clear <strong>water</strong><br />

(Error in Av.)<br />

Turbid <strong>water</strong><br />

(Error in Av.)<br />

nL w mW/cm 2 /μm/sr ±4 % ± 5 %<br />

R rs sr -1 ±4 % ± 5 %<br />

CHL mg/m 3 ±10 % ± 20 %<br />

SS g/m 3 ± 10% ± 10 %<br />

CDOM m -1 ±15% ± 30 %<br />

nL w<br />

: Normalized Water leaving radiance<br />

R rs<br />

: Remote sensing reflectance<br />

CHL : Chlorophyll concentration<br />

SS : Suspended solid particle matter concentration<br />

CDOM : Absorption coefficient of dissolved organic matter at 400 nm