Building <strong>Wire</strong><br />

NM-B <strong>Wire</strong><br />

Cirtex ® Nonmetallic-Sheathed <strong>Cable</strong><br />

90°C Insulation<br />

With Ground <strong>Wire</strong><br />

600 Volts<br />

©2010, <strong>Cerro</strong> <strong>Wire</strong> LLC<br />

All Rights Reserved<br />

MADE IN THE USA<br />

APPLICATIONS<br />

For use primarily in residential wiring, including branch circuits for outlets, switches,<br />

etc. May be installed in both exposed <strong>and</strong> concealed work in normally dry locations.<br />

May be installed in air voids of masonry block or tile walls where these walls are not<br />

subject to excessive moisture or dampness. May be installed in locations with<br />

temperatures up to 90°C, but with the ampacity limited to that of 60°C conductors.<br />

Added Circuit: For use primarily in residential wiring for branch circuits supplying<br />

outlets located in bedrooms <strong>and</strong> other areas.<br />

CONDUCTORS<br />

Solid conductors: Soft, uncoated copper per ASTM-B3<br />

Str<strong>and</strong>ed conductors: Uncoated copper per ASTM-B3 <strong>and</strong> ASTM B8<br />

CONDUCTOR INSULATION AND JACKET<br />

Color-coded PVC (polyvinyl chloride), rated 90°C dry with clear nylon (polyamide).<br />

Added Circuit: Color-coded PVC rated 90°C: black, white, red <strong>and</strong> white with red<br />

stripe. Insulated conductors also jacketed with clear nylon (polyamide).<br />

GROUNDING CONDUCTOR<br />

Soft, uncoated copper per ASTM-B3<br />

ASSEMBLY<br />

Two-conductor constructions have the insulated conductors laid parallel. Ground<br />

wire is wrapped with paper <strong>and</strong> laid parallel between the insulated conductors. The<br />

entire construction is wrapped with a paper separator before applying the jacket.<br />

Three-conductor constructions have the insulated conductors twisted together or laid<br />

parallel to each other. Ground wire is wrapped with paper <strong>and</strong> twisted together or laid<br />

parallel to the insulated conductor.<br />

JACKET<br />

30 mil-thick PVC (polyvinyl chloride) jacket applied over the complete assembly<br />

14-2, 14-2-2 & 14-3 w/ground: white<br />

12-2, 12-2-2 & 12-3 w/ground: yellow<br />

10-2 & 10-3 w/ground: orange<br />

8 AWG or larger: black<br />

INDUSTRY STANDARDS<br />

UL 83 File # E 15119<br />

UL 719 Non-Metallic Sheathed <strong>Cable</strong> File #E9810<br />

ASTM-B3<br />

ASTM-B8<br />

Fed. Spec. A-A-59544<br />

NFPA70: NEC ®<br />

RoHS Compliant<br />

SURFACE PRINT<br />

Sample: NM-B 14-2 W/G 600V Cirtex-A (UL)<br />

REV-11/2011<br />

Electrical Division: 800.523.3869 | FAX 877.877.9563<br />

Consumer Markets Division: 866.572.3776 | FAX 812.793.2626<br />

www.cerrowire.com<br />