www.weg.net<br />
<strong>Enclosed</strong> Direct-on-Line Starter - Accessories<br />
Empty Enclosures<br />
g<br />
IP65<br />
g<br />
For housing one CWC07...16, CWM9...40 contactor <strong>and</strong> one RW overload relay<br />
Illustrative pictures Size Reference Code For use with<br />
Empty enclosure. with ON/OFF operation 02 EB 02P CW07 + RW17 0.200<br />
Weight<br />
kg<br />
04 EB 04P CWM9...25 +RW27 0.275<br />
04 EB 04CP CWC07...16 + RW17 0.275<br />
06 EB 06AP CWM32 + RW27 0.390<br />
06 EB 06BP CWM32...40 + RW67-1D 0.390<br />
Empty enclosure. with STOP/RESET operation 02 EB 02D CW07 + RW17 0.200<br />
04 EB 04D CWM9...25 +RW27 0.275<br />
04 EB 04CD CWC07...16 +RW17 0.275<br />
06 EB 06AD CWM32 + RW27 0.390<br />
06 EB 06BD CWM32...40 + RW67-1D 0.390<br />
Empty enclosure. with HAND/OFF/AUTO operation 02 EB 02B CW07 + RW17 0.210<br />
04 EB 04B CWM9...25 +RW27 0.285<br />
04 EB 04CB CWC07...16 + RW17 0.285<br />
06 EB 06AB CWM32 + RW27 0.400<br />
06 EB 06BB CWM32...40 + RW67-1D 0.400<br />
Wiring Diagram<br />
Three phase D.O.L. Starter<br />
Single-phase D.O.L Starter<br />
L1 L2 L3<br />
L1 L2 L3<br />
N<br />
L<br />
L1<br />
L2<br />
K1<br />
3<br />
I<br />
1 3 5 4<br />
2 4 6<br />
K1<br />
13<br />
14<br />
D<br />
K1<br />
3<br />
I<br />
1 3 5 4<br />
2 4 6<br />
K1<br />
13<br />
14<br />
D<br />
K1<br />
1 5<br />
2 6<br />
I<br />
3<br />
4<br />
K1<br />
13<br />
14<br />
D<br />
FT1<br />
1<br />
2<br />
U1<br />
3 5<br />
4 6<br />
V1<br />
M<br />
3~<br />
W1<br />
0<br />
1<br />
2<br />
95<br />
FT1<br />
96<br />
A2<br />
K1<br />
A1<br />
FT1<br />
1<br />
2<br />
U1<br />
3 5<br />
4 6<br />
V1<br />
M<br />
3~<br />
W1<br />
0<br />
1<br />
2<br />
95<br />
FT1<br />
96<br />
A2<br />
K1<br />
A1<br />
FT1<br />
1<br />
2<br />
U1<br />
M<br />
1~<br />
5<br />
6<br />
U2<br />
FT1<br />
K1<br />
0<br />
1<br />
2<br />
95<br />
96<br />
A2<br />
A1<br />
Figure 1<br />
Control circuit with phase to phase coil supply<br />
When using 230V, 400V, 500V, <strong>and</strong> 690V on the<br />
reference code, WEG D.O.L. starters (DLW) will<br />
be factory-connected, as per wiring diagrams of<br />
figure 1, that is, with phase to phase coil supply.<br />
For the voltages with phase to phase coil supply,<br />
contact WEG.<br />
Figure 2<br />
Control circuit with separate coil supply<br />
When using 24V, 48V, 110V, etc. on the<br />
reference code, WEG D.O.L. starters (DLW) will<br />
be factory-connected, as per wiring diagrams of<br />
figure 2, that is, with control circuit to be<br />
connected through a separate coil supply.<br />
Note: When using remote control, disconnect the circuit at the points marked with the “x” in figures 1 <strong>and</strong> 2 <strong>and</strong> connect the external devices (Thermostat,<br />
pushbutton, etc), as indicated with dotted lines.<br />
108<br />
Low Voltage Switch & Control Gear