You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
O:Option Parameters <strong>for</strong> Elevator<br />
Func NAME LCD Display Setting range Unit Min. Factory setting Change User remark<br />
No. Unit --22kW 30kW-- during op Set value<br />
o34 MCcontrol (Start waiting time)o34 OPTION 34 0.00 to 10.00s s 0.01 0.00 NA<br />
o35 (OFF time) o35 OPTION 35 0.00 to 100.00s s 0.01 0.00 NA<br />
o36 Start time o36 OPTION 36 0.00 to 10.00s s 0.01 0.00 NA<br />
o37 Brake control o37 OPTION 37 0.00 to 10.00s s 0.01 0.00 NA<br />
(Operation check wait time)<br />
o38 Power supply open-phase o38 OPTION 38 0 to 2 - 1 0 NA<br />
detection<br />
o39 Acc/dec calculator select o39 OPTION 39 0 to 1 - - 0 NA<br />
o40 Droop operation (Braking) o40 OPTION 40 -9.9 to 0.0 Hz 0.1 0.0 A<br />
o41 RS485 protocol selection o41 OPTION 41 0 to 1 - - 0 NA<br />
o42 Current vibration control o42 OPTION 42 0 to 32767 - 1 819 A<br />
o43 Slip compensation control o43 OPTION 43 0.00 to 15.00 Hz 0.01 0.00 A<br />
(Braking)<br />
o44 Speed agreement o44 OPTION 44 0 to 50 % 1 10 A<br />
/PG abnormality(Detection width)<br />
o45 (Detection timer) o45 OPTION 45 0.0 to 10.0 s 0.1 0.5 A<br />
o46 PG abnormality error selection o46 OPTION 46 0 to 1 - - 1 NA<br />
o47 Di torque bias 1 o47 OPTION 47 -200% to 200% % 1 0 A<br />
o48 2 o48 OPTION 48 0 A<br />
o49 3 o49 OPTION 49 0 A<br />
o50 Torque bias (Driving side) o50 OPTION 50 0.0 to 200.0% % 0.1 100.0 A<br />
o51 Gain (Braking side) o51 OPTION 51 100.0 A<br />
o52 Torque bias startup timer o52 OPTION 52 0.00 to 1.00 s 0.01 0.20 A<br />
o53 Starting torque comp. (Select)o53 OPTION 53 0 to 1 - - 0 NA<br />
o54 (Calculation start pulse1) o54 OPTION 54 0 to 255 p 1 0 NA<br />
o55 (Calculation start pulse2) o55 OPTION 55 0 to 255 p 1 0 NA<br />
o56 (Pulse count) o56 OPTION 56 0 to 255 p 1 0 A<br />
12 SI27-3762b