- Page 1 and 2: INTERNATIONAL COUNCIL FOR RESEARCH
- Page 3: CONTENTS 1. Chairman's Introduction
- Page 8 and 9: P Mestek J Müller M Sieder P Stape
- Page 11: 1. Chairman's Introduction 2. Gener
- Page 14 and 15: eviewer and clear guidelines for th
- Page 16 and 17: 5 TIMBER JOINTS AND FASTENERS 44 -
- Page 18 and 19: out and geometry. B Franke responde
- Page 20 and 21: J Köhler asked why the simulated r
- Page 22 and 23: 44 - 15 - 7 Seismic Performance of
- Page 24 and 25: Mechanical behaviour of the in-plan
- Page 27: 14. Peer review of papers for the C
- Page 31 and 32: List of CIB-W18 Papers, Alghero, It
- Page 33: 16. Current List of CIB-W18(A) Pape
- Page 36 and 37: denotes the subject: 1 Limit State
- Page 38 and 39: 6-2-3 Comparison of Larsen and Perr
- Page 40 and 41: 20-4-1 Considerations of Reliabilit
- Page 42 and 43: 12-6-1 Strength Classifications for
- Page 44 and 45: 31-6-4 Compression Strength Perpend
- Page 46 and 47: 13-7-2 Investigation of the Effect
- Page 48 and 49: 22-7-10 Calculation of Joints and F
- Page 50 and 51: 31-7-3 Flexural Behaviour of Glulam
- Page 52 and 53: 35-7-12 Fiber-Reinforced Beam-to-Co
- Page 54 and 55:
41-7-5 Embedding Strength of Europe
- Page 56 and 57:
19-1-1 Duration of Load Effects and
- Page 58 and 59:
30-10-4 Load Carrying Capacity of T
- Page 60 and 61:
25-12-1 Determination of Characteri
- Page 62 and 63:
43-12-4 Experimental Investigations
- Page 64 and 65:
26-14-1 Test of Nail Plates Subject
- Page 66 and 67:
29-15-5 Natural Frequency Predictio
- Page 68 and 69:
39-15-2 Which Seismic Behaviour Fac
- Page 70 and 71:
39-16-1 Fire Performance of FRP Rei
- Page 72 and 73:
23-19-2 The Fracture Energy of Wood
- Page 74 and 75:
21-100-1 CIB Structural Timber Desi
- Page 76 and 77:
38-102-1 A New Generation of Timber
- Page 79:
CIB-W18/44-5-1 INTERNATIONAL COUNCI
- Page 82 and 83:
Table 1. Overview of relevant knot
- Page 84 and 85:
equation the MOE of the WS is calcu
- Page 86 and 87:
Cut grains a) b) c) d) Figure 4. a)
- Page 88 and 89:
The correlation coefficient betwee
- Page 90 and 91:
Table 6. Estimated parameters, thei
- Page 92 and 93:
ed knot area ratio (tKAR) are simil
- Page 95 and 96:
Adaptive production settings method
- Page 97 and 98:
Table 1: Average properties of grad
- Page 99 and 100:
This drawback is partially overcome
- Page 101 and 102:
EN 14081-4 settings C40 C30 C18 Rej
- Page 103 and 104:
Table 11: Yields obtained to C40, C
- Page 105:
CIB-W18/44-5-3 INTERNATIONAL COUNCI
- Page 108 and 109:
• The reference, “optimum gradi
- Page 110 and 111:
Table 2 Grade Grade 1 Grade 2 Rejec
- Page 112 and 113:
example Jørgensen (1993). Some req
- Page 114 and 115:
4.2 Determination of the prediction
- Page 116 and 117:
liers will decrease and the setting
- Page 119:
CIB-W18/44-6-1 INTERNATIONAL COUNCI
- Page 122 and 123:
V bh 2 0.6 1 G xy G f d 1 2
- Page 124 and 125:
2.1 Specification of material prope
- Page 126 and 127:
Probability density [-] Fracture en
- Page 128 and 129:
Probability density [-] E x / G xy
- Page 130 and 131:
Both action effects and resistance
- Page 132 and 133:
The suggested new values for the ma
- Page 135:
CIB-W18/44-6-2 INTERNATIONAL COUNCI
- Page 138 and 139:
2 Situations where combined stresse
- Page 140 and 141:
K K 1 1c b 1 2 b 2 K2 K a 2c
- Page 142 and 143:
tensile stresses perpendicular to t
- Page 144 and 145:
4.1.2 Experiments by Spengler at th
- Page 146 and 147:
Elongation Compression set 480 4.2.
- Page 148 and 149:
6 Acknowledgements The providing of
- Page 151:
CIB-W18/44-7-1 INTERNATIONAL COUNCI
- Page 154 and 155:
4 Forintek (n.a.) Wood screw gauge
- Page 156 and 157:
The observations with power nails w
- Page 158 and 159:
References Herzog, B & Yeh, B (2006
- Page 160 and 161:
In Eq. (6) the last term can be the
- Page 163:
CIB-W18/44-7-2 INTERNATIONAL COUNCI
- Page 166 and 167:
2 Experimental tests Within the sco
- Page 168 and 169:
The chart in Fig. 6 illustrates the
- Page 170 and 171:
Table 6: Mean values of proof loads
- Page 172 and 173:
Fig. 13 Central point support / con
- Page 174 and 175:
In this case the capacity of the sc
- Page 176 and 177:
4.3 Verification of the design conc
- Page 178 and 179:
Literature [1] DIN 1052:2008-12: En
- Page 181 and 182:
Fatigue Behaviour of the Stud Conne
- Page 183 and 184:
The primal intention of the current
- Page 185 and 186:
transferring area - were analyzed w
- Page 187 and 188:
The following schematic diagrams (F
- Page 189 and 190:
determined to 46 % of the correspon
- Page 191:
CIB-W18/44-7-4 INTERNATIONAL COUNCI
- Page 194 and 195:
2 Experimental testing This section
- Page 196 and 197:
2.2 Test results In the case of sei
- Page 198 and 199:
3.1 Gap opening As mentioned previo
- Page 200 and 201:
4 Incorporating the Initial Stiffne
- Page 202 and 203:
Acknowledgements The authors wish t
- Page 205 and 206:
Design approach for the splitting f
- Page 207 and 208:
Table 1: Numerical test series GROU
- Page 209 and 210:
3 Design proposal for double shear
- Page 211 and 212:
Figure 8: 3-dim. curve of the norma
- Page 213 and 214:
GÖRLACHER [7] who did tests with n
- Page 215:
CIB-W18/44-12-1 INTERNATIONAL COUNC
- Page 218 and 219:
2 glulam: state of the art 2.1 Char
- Page 220 and 221:
was completed by Y. Halili [3] and
- Page 222 and 223:
Table 3: mechanical properties of C
- Page 224 and 225:
Table 4: mechanical properties of C
- Page 226 and 227:
F glulam F CLT Figure 13: 200 mm hi
- Page 228 and 229:
mm, height=90/200/480 mm) and CLT-p
- Page 230 and 231:
with: s H k c ,90= √ L ⩽5with L
- Page 233:
CIB-W18/44-12-2 INTERNATIONAL COUNC
- Page 236 and 237:
[2]. In this sense, Glos [1] conduc
- Page 238 and 239:
The stress state is plane stress. I
- Page 240 and 241:
The rigid lower steel base, shown i
- Page 242 and 243:
3 Results 3.1 Simulated mechanical
- Page 244 and 245:
Charact. compressive strength [MPa]
- Page 246 and 247:
identified as decisive explanatory
- Page 249 and 250:
Glued Laminated Timber: A proposal
- Page 251 and 252:
k The coefficient k s is determined
- Page 253 and 254:
Lot Depth (mm) Beam lay-up Strength
- Page 255:
Design proposal It is proposed to a
- Page 259 and 260:
Glulam beams with internally and ex
- Page 261 and 262:
F t,V,d h ⎡ h − ⎤ 0, 008 2 =
- Page 263 and 264:
3 Verification of the reinforcement
- Page 265 and 266:
was derived for round holes from a
- Page 267 and 268:
adii, dependant on the aspect ratio
- Page 269 and 270:
The nominal/outer diameter of the s
- Page 271:
CIB-W18/44-12-5 INTERNATIONAL COUNC
- Page 274 and 275:
of different sizes and grades to es
- Page 276 and 277:
3.2 Beam B12, B24, and B36 Tests Th
- Page 278 and 279:
Table 4. Summary of the simulation
- Page 280 and 281:
5 Beam Size Effects in Bending The
- Page 282 and 283:
6 Recommendations for CSA O86 1) Al
- Page 285 and 286:
A proposal for revision of the curr
- Page 287 and 288:
Detailing rules. Detailing rules fo
- Page 289 and 290:
Other constructive systems used for
- Page 291 and 292:
Connection between floors and walls
- Page 293 and 294:
In order to ensure the development
- Page 295 and 296:
connections, failure modes a, b and
- Page 297:
The proposal presented in this pape
- Page 301 and 302:
Influence of vertical loads on late
- Page 303 and 304:
P h where P = vertical reaction a
- Page 305 and 306:
where ν = unit shear load at the t
- Page 307 and 308:
Wall length Vertical restraint cond
- Page 309 and 310:
Figure 4 shows that the deflections
- Page 311:
Appendix. Experimental and predicte
- Page 315 and 316:
Modelling Force Transfer Around Ope
- Page 317 and 318:
Most walls were tested with a cycli
- Page 319 and 320:
techniques is presented by Martin (
- Page 321 and 322:
Internal force (kN) Wall 04 ‐ Str
- Page 323 and 324:
The current WALL2D model considers
- Page 325:
CIB-W18/44-15-4 INTERNATIONAL COUNC
- Page 328 and 329:
(Girhammar et al. 2010). The formul
- Page 330 and 331:
2. Analysis methods In this section
- Page 332 and 333:
can be used to investigate the qual
- Page 334 and 335:
y x (a) (b) Figure 7. (a) The posit
- Page 336 and 337:
Figure 10. Load in the rail as a fu
- Page 338 and 339:
In the present case, this would cor
- Page 341:
CIB-W18/44-15-5 INTERNATIONAL COUNC
- Page 344 and 345:
Increased robustness of timber stru
- Page 346 and 347:
2 moments in the spans become Ms q
- Page 348 and 349:
The symbol w 0 denotes the maximum
- Page 350 and 351:
of m for the same value of q . Simi
- Page 352 and 353:
Figure 9: Roof beam system The load
- Page 354 and 355:
structural fundamental period comes
- Page 356 and 357:
where the strain leading to stress
- Page 358 and 359:
[2] European Standard EN 1991-1-7:2
- Page 361 and 362:
Enhanced Model of the Nonlinear Loa
- Page 363 and 364:
a) 4-node-element to model an elast
- Page 365 and 366:
u = cosh( λx) C1 + sinh( λx) C2 w
- Page 367 and 368:
directions. The ratio of the load c
- Page 369 and 370:
Interconnection Stress Parallel To
- Page 371:
CIB-W18/44-15-7 INTERNATIONAL COUNC
- Page 374 and 375:
collaboration with Japanese researc
- Page 376 and 377:
VII were placed over a 94mm thick C
- Page 378 and 379:
Load [kN] Load [kN] Load [kN] Load
- Page 380 and 381:
Load [kN] 120 90 60 30 0 -30 -60 -9
- Page 382 and 383:
aced timber frames [12], the perfor
- Page 385 and 386:
Evaluation of plywood sheathed shea
- Page 387 and 388:
side member were measured with elec
- Page 389 and 390:
30 Screw: 3832 30 Screw: 4138 20 20
- Page 391 and 392:
Table 3 Characteristic values of si
- Page 393 and 394:
the displacement at maximum load. A
- Page 395:
CIB-W18/44-15-9 INTERNATIONAL COUNC
- Page 398 and 399:
2 Case study 2.1 Geometry and loads
- Page 400 and 401:
3.1 Lateral force method The buildi
- Page 402 and 403:
Freedom (MDOF) system are first com
- Page 404 and 405:
e tension in the bracket connectors
- Page 406 and 407:
changes for walls with large openin
- Page 409:
CIB-W18/44-16-1 INTERNATIONAL COUNC
- Page 412 and 413:
SP Trätek CIB W18 Meeting 2011, Al
- Page 414 and 415:
SP Trätek CIB W18 Meeting 2011, Al
- Page 416 and 417:
SP Trätek 5 Discussion CIB W18 Mee
- Page 418 and 419:
SP Trätek CIB W18 Meeting 2011, Al
- Page 421 and 422:
Influence of sample size on assigne
- Page 423 and 424:
0.78) ). This is done to account fo
- Page 425 and 426:
Table 1 summarizes the available da
- Page 427 and 428:
4 Results The grading results for t
- Page 429 and 430:
atio 1.6 1.5 1.4 1.3 1.2 1.1 1.0 0.
- Page 431 and 432:
all samples was reached for a cumar
- Page 433:
CIB-W18/Notes INTERNATIONAL COUNCIL
- Page 436 and 437:
Figure 1: Arrangement of beams and
- Page 439 and 440:
Splitting of beams loaded perpendic
- Page 441:
Table 2 Failure load of beams loade
- Page 444 and 445:
Table 1 - Details of tested wall-to
- Page 447 and 448:
1 Research note: Compression perpen
- Page 449:
3 Annex 1: Recommendation For sills
- Page 452 and 453:
lower side of the specimen that is
- Page 455 and 456:
25/10/2011 New Zealand’s tectonic
- Page 457:
25/10/2011 Soft storey collapse Sol
- Page 460 and 461:
25/10/2011 Associate Professor Stef
- Page 463 and 464:
Damage of wooden houses due to Tsun
- Page 465:
4 Design of timber structures again
- Page 468 and 469:
SP Trätek CIB W18 Meeting 2011, Al
- Page 471 and 472:
Reliability Based Code Calibration
- Page 473 and 474:
format of the design equation, cho