Senior Design<br />
110<br />
Conformal Cam Follower Design<br />
111<br />
Electric Park Brake Design<br />
112<br />
Instrumentation for Quantitatively<br />
Assessing Tremors<br />
An example of adhesive wear caused by Hertzian<br />
contact stresses (top left); a roller follower<br />
in contact with a camshaft (bottom left); the<br />
stress distribution at the roller-to-cam interface<br />
simulated using finite elements (middle right).<br />
Team Members<br />
Michael Rademacher, Brian Sollars, Skyler Teske,<br />
Jiongxun Zhang, and Venkatesh Shetty, Mechanical<br />
Engineering<br />
Advisor<br />
Dr. Gregory Odegard<br />
Sponsors<br />
Oliver Bouthier and Carl Musolff, Cummins Mid-<br />
Range Applied Mechanics<br />
Project Overview<br />
In the ISX 15.0-liter diesel engine, Cummins<br />
currently utilizes a convex-to-convex interface<br />
between roller followers and cams. The advantage<br />
of this design lies in the fact that high stress, due<br />
to edge contact, is eliminated. However, the small<br />
point of contact at this interface creates high<br />
Hertzian stresses. The project investigates the<br />
possibility of using a more conformal convex-toconcave<br />
interface. Theoretically, this design will<br />
create a larger area of contact between the rollers<br />
and cams and, therefore, reduce Hertzian stress.<br />
Motor on caliper 3-D CAD model<br />
Team Members<br />
BShiran Chen, Joshua Howell, Fei Pi, and Jeff Rice,<br />
Mechanical Engineering; Brian Thompson and<br />
Jared Helminen, Electrical Engineering<br />
Advisor<br />
Dr. John Beard, Mechanical Engineering-<br />
Engineering Mechanics<br />
Sponsor<br />
HB Performance Systems Inc.<br />
Project Overview<br />
Design an electric parking brake—to replace the<br />
cable-driven parking brake—on Harley Davidson<br />
Tri-Glide and Can-Am Spyder three-wheel<br />
motorcycles.<br />
An instrument for quantitatively assessing tremors<br />
of the hands<br />
Team Members<br />
Cody Alger, Jacob Gombar, Daniel Hirst, Michael<br />
Hulway, and Amy Saelen, Biomedical Engineering<br />
Advisor<br />
Dr. Keat Ghee Ong<br />
Sponsor<br />
Department of Biomedical Engineering<br />
Project Overview<br />
Currently there is no effective way to quantify the<br />
magnitude and frequency of essential tremors in<br />
the hands. Therefore, the goal is to design and<br />
build a device that quantitatively assesses these<br />
variables. This device must be able to record<br />
the frequency and magnitude of the tremor, with<br />
minimal interference from outside factors, while<br />
remaining cost-effective. In addition, this device<br />
must have a high level of precision and accuracy<br />
so the results can be compared to previous trials<br />
to determine trends in tremor behavior—as well<br />
as help determine whether specific treatments are<br />
having measurable effects in reducing the tremor.<br />