Gears<br />

Electromagnetic HID Gear<br />

Master Electronic HID Control Gear<br />

HID Primavision Compact<br />

• Wide range of HID gear and ignitors for<br />

general industrial applications: BSN gear for<br />

high-pressure sodium/ BMH gear for metal<br />

halide/ BHL gear for mercury (HPL)/ BPI<br />

gear for quartz metal halide (HPI)/ BSL gear<br />

for SDW-T.<br />

• Lacquer-filled, humidity-proof ballasts for<br />

built-in luminaires with an IP rating of 42 or<br />

higher.<br />

• Thermo-protected ballasts and built-in timer<br />

ignitors with automatic end-of-life switch off<br />

to safeguard the circuit.<br />

• Improved Temperature behavior, and the<br />

lifetime of 40.000 hrs (@90% survivors) is<br />

specified at Tcase, max and/or Tambient,<br />

max.<br />

• High quality gear.<br />

• Optimum system performance.<br />

• Flicker free operation.<br />

• 30 to 40% longer lamp lifetime.<br />

• 10% energy saving compared to an<br />

electromagnetic system.<br />

• Safe and comfortable behavior when lamp<br />

reaches end of life.<br />

<strong>Philips</strong> green products set an example in terms<br />

of their environmental performance and are<br />

characterized by superior performance. Products<br />

that carry a Green logo have been independently<br />

reviewed by a third party as signifi cantly better in<br />

comparison to other products on the market in at<br />

least one of the following green focal areas:<br />

<strong>Energy</strong> Effi ciency<br />

Hazardous Substances<br />

Packaging<br />

HF Performer III for TL-D<br />

• <strong>Energy</strong> <strong>efficient</strong> CELMA A2.<br />

• ENEC & CE approval, complying to all<br />

relevant international safety and performance<br />

standards.<br />

• Robust design for 50.000 hour lifetime at<br />

Tcmax and over 60.000 on/off switches on.<br />

• Programmed, flicker-free, preheated start<br />

(< 1.6 s) enabling the lamp to be switched<br />

on/off without reducing lamp lifetime (e.g.<br />

for use in combination with <strong>lighting</strong> control<br />

components).<br />

• High power factor 0.99 with THD < 10%.<br />

• Automatic restart after voltage dip or lamp<br />

exchange.<br />

• Suitable for emergency DC operation of<br />

186V to 275V (at –10 ˚C), in line with IEC/EN<br />

60598-2-22.<br />

• High frequency operation; eliminating eye<br />

strain as caused by electromagnetic ballasts.<br />

• EMC compliant to EN 55015 2006 + A1 2007.<br />

• Unit is protected against excessive mains<br />

voltage and incorrect connections.<br />

• Active power factor correction for constant<br />

light levels independent of mains voltage<br />

fluctuations.<br />

HF-Performer III for TL5<br />

• <strong>Energy</strong> <strong>efficient</strong> CELMA A2 BAT.<br />

• ENEC & CE approval, complying to all<br />

relevant international safety and performance<br />

standards.<br />

• Robust design for 50.000 hour lifetime at<br />

Tcmax and over 60.000 on/off switches on<br />

one lamp.<br />

• Programmed, flicker-free, preheated start (<<br />

1.0 s) enabling the lamp to be switched on/off<br />

without reducing lamp lifetime (e.g. for use in<br />

combination with <strong>lighting</strong> control components)<br />

• High power factor 0.99 with THD < 10%.<br />

• Automatic restart after voltage dip or lamp<br />

exchange.<br />

• Suitable for emergency DC operation, 186V to<br />

275V (at –10 ˚C), in line with IEC/EN 60598-<br />

2-22.<br />

• High frequency operation; eliminating eye<br />

strain as caused by electromagnetic ballasts.<br />

• EMC compliant to EN 55015 2006 + A1 2007.<br />

• Unit is protected against excessive mains<br />

voltage and incorrect connections.<br />

• Active power factor correction for constant<br />

light levels independent of mains voltage<br />

fluctuations.<br />

Lifetime Reliability<br />

Recyclability<br />

Weight<br />

HF-Regulator for TL-D/ TL-5<br />

ActiLume <strong>lighting</strong> control system<br />

• Power factor: 0.95 for TL-D/ TL-5.<br />

• System power: 37W for TL-D, 33W for TL-5.<br />

• Suitable for mains voltage: 220-240V/50-60Hz.<br />

• Meets relevant IEC safety and<br />

performance standards.<br />

• Lamp power can be regulated down to<br />

3% through 1-10V control input.<br />

• Consists out of three state-of-art miniature sensors<br />

combined with a controller containing a series of<br />

pre-programmed modes.<br />

• The light sensor provides automatic savings with<br />

daylight depending regulation.<br />

• The movement detector is sensitive to human<br />

movements and is combined with extended delays.<br />

• A true Plug and Play solution-used in a master and<br />

slave luminaire concept, <strong>easy</strong> to use and <strong>easy</strong> to<br />

install.<br />

• Maximum comfort and energy savings of up to 75%<br />

(in fully automatic mode and when used in<br />

combination with <strong>Philips</strong> HFRegulatorII Touch<br />

and DALI ballasts).<br />

• DALI based <strong>lighting</strong> control system.<br />