:: Capacities and Main Dimensions - <strong>RVK</strong> Units<br />

The units are cast into the precast stair or landing, and all that is required in the wall is a recess. During<br />

erection the inner tube is retracted into the unit, to be pushed out into the recess when the precast element<br />

is in the correct position. A rubber pad at the support in the wall is available in order to reduce the impact<br />

sound transfer from the stairs to the walls.<br />

<strong>RVK</strong> Dimensions:<br />

<strong>RVK</strong> Unit<br />

Ultimate Capacity (VV)<br />

(kN)<br />

Min Slab thickness<br />

For full capacity (mm) For space (mm)<br />

Capacity in transverse<br />

direction (VH) (kN)<br />

40<br />

100<br />

40<br />

100<br />

150<br />

265<br />

150<br />

200<br />

50<br />

100<br />

<strong>RVK</strong> Unit<br />

L (mm) L1 (mm) L2 (mm) L3 (mm) h (mm) h1 (mm) b1 (mm) b2 (mm)<br />

40<br />

100<br />

303<br />

353<br />

280<br />

300<br />

160<br />

190<br />

100<br />

120<br />

50<br />

70<br />

110<br />

140<br />

90<br />

130<br />

41<br />

51<br />

<strong>RVK</strong> Unit<br />

Tube dimensions b/h/t (mm)<br />

outer tube<br />

inner tube<br />

Clearances between tubes (mm)<br />

vertically<br />

horizontally<br />

Dimension of<br />

threaded insert<br />

40<br />

100<br />

80/50/4<br />

120/60/4<br />

70/40/4<br />

100/50/8<br />

2<br />

2<br />

2<br />

12<br />

M16<br />

M20<br />

6