DEFINITIONS OF TERMS<br />
Date <strong>of</strong> Activity- Actual date activity took place. Includes preparation at <strong>of</strong>fice<br />
and on jobsite activities.<br />
Activity – Direct participation by applicator in identifying infestations,<br />
recommendations, estimates, bids, and disclosures, making contracts, submitting<br />
bids or performing services, preparing structures for fumigation, applying<br />
fumigants, and clearing structures. Applicators must actively participate in 9 <strong>of</strong><br />
the following tasks on each <strong>of</strong> three fumigations to receive credit. If an<br />
applicator participates in additional fumigations within the license year,<br />
there is no requirement to record the additional fumigations on this form.<br />
1. Inspect structure and identify <strong>pest</strong>(s) prior to fumigation<br />
2. Prepare disclosure documents pursuant to the provisions <strong>of</strong> §599.4 <strong>of</strong> the<br />
SPCS regulations<br />
3. Measure structure and calculate volume<br />
4. Calculate dosage <strong>of</strong> Fumigant<br />
5. Notify local fire or police authority as appropriate<br />
6. Secure materials left inside structure, check pilot lights & appliances<br />
7. Tarp, place snakes, or otherwise seal structure for fumigation<br />
8. Post the structure and secure entrances to the structure<br />
9. Instruct the person (guard) on duty at the site on responsibilities and safety<br />
precautions<br />
10. Provide onsite supervision during application (only one applicator per<br />
company may claim provision <strong>of</strong> onsite supervision)<br />
11. Set up equipment including splash pan and fans for<br />
12. Introduce fumigant and warning agent (if required) to the structure<br />
13. Aerate structure<br />
14. Take down tarps, remove snakes, remove locks, or otherwise remove<br />
sealing material<br />
15. Clear the structure<br />
16. Provide onsite supervision during aeration and clearing(only one<br />
applicator per company may claim provision <strong>of</strong> onsite supervision)<br />
17. Store and/or dispose <strong>of</strong> fumigant containers<br />
18. Prepare the report <strong>of</strong> fumigation required by §599.9(j) <strong>of</strong> the SPCS<br />
regulations<br />
09-01-07