The user may use the following simple equation for making an<br />
approximate calculation:<br />
Number of falls<br />
2<br />
metres of climbing x 0.33 + metres<br />
of abseiling x 1.66 = metres of use<br />
15 Standard falls<br />
10 Standard falls<br />
5 Standard falls<br />
4 6 8 10 12 x 1000m<br />
Rope with 5 standard falls<br />
Rope with 10 standard falls<br />
Rope with 15 standard falls<br />
Formula for calculating<br />
Abseiling (m) x 1,66<br />
Climbing (m) x 0,33<br />
cumulated<br />
Metres of use<br />
Metres of use<br />
When documenting the metres of use cumulatively, the user may<br />
estimate the safety condition of the rope (safety reserve of the<br />
number of falls) from the number of metres of use of the rope since<br />
the first day of use.<br />
General values of safety condition (safety reserve)<br />
According to curves depicted in the graph for individual rope types:<br />
TENDON 11.4 mm Trust 20 standard falls on the day of<br />
production<br />
TENDON 11.0 mm Trust 16 standard falls on the day of<br />
production<br />
TENDON 10.5 mm Ambition 11 standard falls on the day of<br />
production<br />
The number of cumulated metres may be used to estimate the<br />
remaining safety condition/safety reserve (number of standard falls)<br />
of the rope.<br />
Estimated safety condition of <strong>ropes</strong> used with different<br />
intensity (TENDON 11 mm Trust):<br />
• Safety condition >/= 5 standard falls (up to approx. 6,000-8,000<br />
metres of use)<br />
If the rope is in perfect condition, it may be used to secure any<br />
climbing situation up to a fall factor of 2.<br />
• Safety condition > 2 standard falls (up to approx. 12,000-14,000<br />
metres of use)<br />
If the rope is in perfect condition, it may be used to secure any<br />
climbing situation up to a fall factor of 1.<br />
• Safety condition