INSTRUCTIONAL INFORMATION<br />

For convenience in matching filters, regulators,<br />

and lubricators, ROSS units are grouped in five<br />

series of increasing flow capacity: Bantam,<br />

Miniature, Mid-Size, Full-Size, MD4 TM , and<br />

High-Capacity.<br />

BANTAM Series. For flow to 30 scfm (14 l/s);<br />

port sizes 1/8 and 1/4; tube fittings 1/4 to 10 mm.<br />

Modular components are joined without pipe<br />

nipples; ports are O-ring sealed.<br />

MINIATURE Series. For flow to 20 scfm<br />

(9.4 l/s); port sizes 1/8 and 1/4. Units joined by<br />

pipe nipples.<br />

MID-SIZE Series. For flow to 75 scfm (35 l/s);<br />

port sizes 1/4, 3/8, 1/2. Connection of units by<br />

either special modular connectors or by pipe<br />

nipples.<br />

FULL-SIZE Series. For flow to 155 scfm<br />

(73 l/s); port sizes 1/4 through 3/4. Connection<br />

of units by either special modular connectors or<br />

by pipe nipples.<br />

MD4 TM Series. For flows to 205 scfm, port sizes<br />

3/8” to 3/4” units joined by positive-seal clamps.<br />

<strong>HIGH</strong>-<strong>CAPACITY</strong> Series. For flow to 1000 scfm<br />

(448 l/s); pipe sizes 3/4 through 2. Connection<br />

of units only by pipe nipples.<br />

FILTER RATINGS. ROSS conventional filters<br />

have 5-micron ratings<br />

compared to the usual industry<br />

standard 40-micron<br />

rating. 40-micron<br />

particles have 500 times<br />

the volume of 5-micron<br />

particles, so it’s easy to<br />

see why ROSS filters<br />

clean best.<br />

ROSS coalescing filters<br />

5 Microns<br />

40 Microns<br />

COMPARATIVE SIZE<br />

remove 99.98% of oil from the air as well as solids<br />

as small as 0.3 micron. A filter as fine as this<br />

should be preceded by a conventional 5-micron<br />

filter to prolong its service life. Full-Size and<br />

High-Capacity units have built-in differential<br />

pressure gauges to show when the coalescing<br />

element must be changed.<br />

ROSS OIL VAPOR REMOVAL. Adsorbing filters<br />

remove oil and hydrocarbon vapors that<br />

cannot be removed by a coalescing or a general<br />

purpose filter. It is used by industries such<br />

as food processing, electronics, and instrumentation.<br />

FILTER DRAINS. Most ROSS filters are available<br />

with either manual or automatic drains. An<br />

automatic drain discharges liquids accumulated<br />

in the filter bowl whenever there is a pressure<br />

drop. This ensures better filter performance and<br />

simplifies maintenance, especially of filters in<br />

inaccessible locations. ROSS strongly<br />

recommends the use of automatic drains.<br />

PRESSURE REGULATORS. Both piston and<br />

diaphragm styles are available. All are self-relieving<br />

and give accurate and consistent pressure<br />

regulation. In the Miniature, Full-Size,<br />

MD4 TM , and High-Capacity series precision<br />

regulators are offered. They provide the most precise<br />

regulation throughout their flow ranges.<br />

Mid-Size, Full-Size, and High-Capacity series<br />

also offer reverse-flow regulators for special applications.<br />

LUBRICATORS. Two systems of introducing oil<br />

into the air stream are used in ROSS lubricators.<br />

Wick-feed. A porous bronze rod carries oil from<br />

the lubricator bowl up to the air passage by capillary<br />

action, and the air stream picks up the oil.<br />

This is a self-adjusting system because the<br />

amount of oil added to the air is in proportion to<br />

the air flow.<br />

Sight-feed. A riser tube brings the oil up to an<br />

adjustable metering valve within a transparent<br />

dome, where it then drips into the air stream. A<br />

vane in the path of incoming air creates the small<br />

pressure drop that draws oil up the riser tube.<br />

This occurs even at very low air flows so that no<br />

air passes without being lubricated.<br />

CONSOLIDATED FILTER & REGULATOR. A<br />

filter and a regulator consolidated into a single<br />

space-saving assembly is available in all sizes<br />

except the High-Capacity series.<br />

Pre-assembled combinations of filter, regulator,<br />

and lubricator units are available in all series.<br />

4 © Copyright 2005 - ROSS CONTROLS ®<br />