07.07.2015 Views

A Review of Aggregate and Asphalt Mixture Specific Gravity ...

A Review of Aggregate and Asphalt Mixture Specific Gravity ...

A Review of Aggregate and Asphalt Mixture Specific Gravity ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

aggregate with less than 1.0% water absorption. The precision estimates from D 2726 areshown in Table 13 <strong>and</strong> indicate that the method is less repeatable (i.e. higher within-labprecision) for the coarse-graded specimens compared to fine-graded specimens. Potentialsources <strong>of</strong> variation for the SSD method discussed by AMRL include differences in thedampness <strong>of</strong> the towel used to blot the surface <strong>of</strong> the specimen, temperature <strong>of</strong> the waterbath, <strong>and</strong> differences in the interpretations for achieving the SSD condition as quickly aspossible.TABLE 13Single Operator Precision:12.5-mm NMAS (fine-graded)19.0-mm NMAS (coarse-graded)Multilaboratory Precision:12.5-mm NMAS (fine-graded)19.0-mm NMAS (coarse-graded)ASTM D 2726 Precision Estimates for G mbSt<strong>and</strong>ard Deviation(1s)0.0080.0130.0150.015Acceptable Range <strong>of</strong>Two Results(d2s)0.0230.0370.0420.042NCHRP Project 9-26 (11) recently completed a significant study that evaluatedthe precision estimates for G mb . The study involved more than 22 laboratories thatcompacted specimens to 100 gyrations in the Superpave Gyratory Compactor inaccordance with AASHTO T 312 then tested the compacted specimens in accordancewith AASHTO T 166 <strong>and</strong> ASTM D 6752 (the vacuum sealing method). Materialsvariables included two aggregate types (low <strong>and</strong> high absorption) <strong>and</strong> two NMASmixtures. The findings <strong>of</strong> this study were that mixtures with different NMAS <strong>and</strong> thosecontaining high <strong>and</strong> low absorptive aggregate yielded similar precision estimates for G mb .This study recommended the precision estimates shown in Table 14 for AASHTO T 166.TABLE 14 NCHRP 9-26 Recommended Precision Estimates for AASHTO T 166Acceptable Range <strong>of</strong>St<strong>and</strong>ard Deviation(1s)Two Results(d2s)Single Operator Precision 0.012 0.033Multilaboratory Precision: 0.016 0.0445.3. Alternatives to St<strong>and</strong>ard Test MethodsSeveral alternative methods available for determining G mb are listed in Table 14 withtheir associated advantages <strong>and</strong> disadvantages.20

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!