09.07.2015 Views

Data sheet English - Bosch Solar Energy AG

Data sheet English - Bosch Solar Energy AG

Data sheet English - Bosch Solar Energy AG

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Bosch</strong> <strong>Solar</strong> Module c-Si M 48 | EU40123Length[x]Crystalline solar modulePerformance classesPerformance sortingStructureCellsMechanical loadElectrical characteristics for STC 1 :DesignationWidth[y]Pmpp[Wp]Frame height[z]Vmpp[V]185 Wp, 190 Wp, 195 Wp, 200 Wp–0/+4.99 WpGlass-foil laminate Anodized aluminum frame Junction box (IP 65) with 3 bypass diodes Weather-resistant back <strong>sheet</strong> (white)48x monocrystalline solar cells in 156 mm x 156 mm format5400 Pa superimposed load, 2400 Pa suction load,in accordance with IEC 61215 (extended test)Impp[A]Voc[V]Isc[A]Reverse-currentload capacity Ir [A]200 200 23.96 8.41 30.25 8.97 25195 195 23.80 8.30 30.17 8.87 25190 190 23.49 8.08 30.01 8.68 25185 185 23.34 7.97 29.93 8.58 25Reduction in module efficiency with decrease in irradiation level from 1000 W/m² to 200 W/m² (at 25 °C):–0.16 % (absolute); measuring tolerance Pmpp ±3 %Electrical characteristics for NOCT 1 :WeightJunctionboxPlugconnectortypeCable[l]1342.0 990.0 50.0 16 Spelsberg MC4 –800+1200x, y, I in mm, ±2; z in mm, ±0.3; weight in kg ±0.5Notes on assembly: See installation andoperating manual at:www.bosch-solarenergy.com/products Horizontal and verticalassembly possible System voltage max. 1000 V Operating temperature range–40 to 85 °CWeak light performance:Intensity[W/m 2 ]Vmpp[%]Impp[%]800 0.0 –20600 0.0 –40400 0.0 –60200 –1.6 –80100 –4.8 –90The electrical data applies for25 °C and AM 1.5.Thermal characteristics:TemperaturecoefficientTK[%/K]Pmpp –0.44Uoc –0.31Isc 0.031DesignationPmpp[W]Vmpp[V]200 145 21.61 27.79 7.23195 142 21.49 27.72 7.15190 138 21.21 27.57 6.99185 134 21.07 27.50 6.91NOCT: Normal Operation Cell Temperature 48.4 °C: Irradiation level 800 W/m², AM 1.5, temperature 20 °C,wind speed 1 m/s, electrical open circuit operationVoc[V]Isc[A]Dimensions 2 :zy1200x8001Electrical parameters are typical mean values from historical production data. No guarantee is made for theaccuracy of this data for future production batches.2Drawings are not to scale. For detailed dimensions and tolerances, see above.<strong>Bosch</strong> <strong>Solar</strong> <strong>Energy</strong> <strong>AG</strong>Robert <strong>Bosch</strong> Straße 199310 ArnstadtGermanyPhone: +49 (0)3628 6644-0Fax: +49 (0)3628 6644-1133sales.se@de.bosch.comwww.bosch-solarenergy.comThe <strong>Bosch</strong> <strong>Solar</strong> <strong>Energy</strong> <strong>AG</strong> installation and operating instructions must be followed. <strong>Bosch</strong> <strong>Solar</strong> <strong>Energy</strong> <strong>AG</strong> acceptsno liability for damage to equipment operated in conjunction with solar modules from <strong>Bosch</strong> <strong>Solar</strong> <strong>Energy</strong> <strong>AG</strong> withoutregard to the technical data<strong>sheet</strong>s. Subject to technical modifications in the course of product development andmistakes/errors.Version: 10/2012

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!