10.07.2015 Views

HP StorageWorks 2000sa Modular Smart Array

HP StorageWorks 2000sa Modular Smart Array

HP StorageWorks 2000sa Modular Smart Array

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

QuickSpecs<strong>HP</strong> <strong>StorageWorks</strong> <strong>2000sa</strong> <strong>Modular</strong> <strong>Smart</strong> <strong>Array</strong>Family InformationPerformancefault tolerance. RAID 50 combines the block striping and parity of RAID5 with the straight block striping of RAID 0, yielding higher performancethan RAID 5 through the addition of RAID 0, particularly during writes.Performance numbers are a guideline as established by tests in a labenvironment. Forty-eight 300GB 15K SAS drives were used indual controller configurations of four vDisks with 12 physical drives pervDisk. Each vDisk presented a single volume of maximum capacityaccording to RAID level.Number and type of applications, number of hosts will affect overallperformance.Workload MSA2012sa MSA2212fc MSA2012fc MSA2012iMSA2000 RAID 10 Performance Results (rounded)Random Reads IOPs 10,600 11,200 10,600 8,200Random Writes IOPs 4,900 7,800 5,000 4,500Random Mix IOPs 60/40read/write6,800 8,900 6,700 6,100Sequential Reads MB 700 1000 650 300Sequential Writes MBs 350 470 330 260MSA2000 RAID 5 Performance Results (rounded)Random Reads IOPs 10,200 10,700 10,200 7,800Random Writes IOPs 2,000 2,400 1,700 1,600Sequential Reads MBs 700 1,000 670 300Sequential Writes MBs 380 580 380 270Random Mix IOPs 60/40read/writeMSA2000 RAID 6 Performance Results (rounded)3,300 3,500 5,700 3,200Random Reads IOPs 10,100 10,700 10,100 7,800Random Writes IOPs 1,400 1,700 1,200 1,200Sequential Reads MBs 700 1,000 680 300Sequential Writes MBs 380 580 380 270Random Mix IOPs 60/40read/writeConfiguration andManagement ToolsHot Plug Expansionand ReplacementSupportSnapshot and Clone2,750 4,200 2,650 2,560<strong>HP</strong> <strong>StorageWorks</strong> MSA Storage Management Utility (SMU),Management access, out-of-band: WEB GUI, CLI. Interface Types: MiniDB9 RS232, 10/100 Ethernet Protocols Supported SNMP, SSL, SSH,SMTP, HTTP, TelnetThe MSA<strong>2000sa</strong> supports hot plug expansion and replacement ofredundant controllers, fans, power supplies, and I/O modules forsimple, fast installation and maintenance.Optional controller based functionality. Offers higher levels of dataprotection, enabling an almost instant recovery from data failure orcorruption. Offers alternative development testing of 'offline' productiondata and the ability to backup snapped/cloned dataDA - 13045 Worldwide QuickSpecs — Version 5 — 2/6/2009 Page 7

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!