Free, Combined and Total Chlorinein Pool and Sanitary <strong>Water</strong>Free Chlorine and Total Residual Chlorine MeasurementMeasuring range: Accuracy:0.00 – 1.00 ppm ± 0.01 ppm1.00 – 3.00 ppm ± 0.06 ppm3.00 – 5.00 ppm ± 0.2 ppmCombined Chlorine will be calculated from thedifference of total residual chlorine and free chlorine.Analytical System• Greatest long-term stability by automatic zeropoint adjustment be<strong>for</strong>e every reading.• High operating reliability because of constantcontrol of sample flow and reagent level.Transmitter <strong>AMI</strong> <strong>Codes</strong>-<strong>II</strong> <strong>CC</strong>• Rugget Aluminum housing IP66.• Two freely scalable current signal outputs(0/4 - 20 mA), third one as an option.• Optional fieldbus communication board.A82-312.000Cleaning Module <strong>for</strong> the periodical,automatic cleaning of the flow celland photometer.For technical specifications seeData Sheet No:DenA82312000 Cleaning ModuleFlow cell• Made of acrylic glass with water inlet filterand needle valve.• <strong>Water</strong> consumption: min. 10 l/h• <strong>Water</strong> inlet pressure: 0.15 to 2 barMade in SwitzerlandANALYTICAL INSTRUMENTSwww.swan.ch · <strong>SWAN</strong> ANALYTISCHE INSTRUMENTE AG · CH-8340 HINWIL/SWITZERLAND · PHONE +41 44 943 63 00
<strong>SWAN</strong> Analytische Instrumente AGCH-8340 Hinwil/SwitzerlandTel. +41 44 943 63 00swan@swan.ch .www.swan.chMonitor <strong>AMI</strong> <strong>Codes</strong>-<strong>II</strong> <strong>CC</strong>Data sheet no. DenA2544X7XX0Complete monitoring system <strong>for</strong> the automatic, continuous measurement of free chlorine,monochloramine, total residual chlorine and combined chlorine in potable water,sanitary water and effluent.Monitor <strong>AMI</strong> <strong>Codes</strong>-<strong>II</strong> <strong>CC</strong>• For the continuous online determination of disinfectantsbased on the DPD colorimetric method(EN ISO 7393-2; APHA 4500-Cl G).• Measurement values : free chlorine, monochloramine,total residual chlorine, combinedchlorine, flow and if installed pH and temperature.• Also applicable <strong>for</strong> water containing additives likecyanuric acid.• Complete system including measurement andcontrol electronics, photometer, flow indicator, reactionchamber, reagent dosing system and reagentcontainers.• Integrated pH measurement with temperaturecompensation (available as option).• All usual dosing devices <strong>for</strong> disinfectants and pHcontrol can be connected either through relays oranalog output signals. Two independent controllerscan operate simultaneously.• Dosing of disinfectant can be interrupted automaticallywith an external signal, e.g. during sampleflow interruption or filter backwashing.• Two (optionally three) selectable measurementvalues are available as analog output signals.• Alarm display and activation of alarm relay whenuser defined, critical limits <strong>for</strong> a measurementvalue are reached.• Continuous, automatic monitoring of main instrumentfunctions (dirty photometer, sample flow,reagents).• Large back-lit LCD display showing all measuredvalues and status in<strong>for</strong>mation simultaneously.• Factory tested, ready <strong>for</strong> installation and operation.Options:• pH option containing pH sensor, temperaturesensor, cables and electronics board.• Chemical cleaning module. For details pleasesee separate data sheet no. DenA82312000.Order scheme Monitor <strong>AMI</strong> <strong>Codes</strong>-<strong>II</strong> <strong>CC</strong> A – 2 5 . 4 4 X. 7 X. 0↑ ↑ ↑Power supply: 100 - 240 VAC, 50/60 Hz ..................................................................... 1 | |24 VDC, direct current .......................................................................... 2 | |pH measurement: None ....................................................................................................................... 0 |pH- and integrated temperature measurement ...................................................... 1 |Electrical output options: None ............................................................................................................................... 0Third current signal output 0/4 - 20 mA .......................................................................... 1Profibus DP interface ..................................................................................................... 2HyperTerminal interface (<strong>for</strong> logger download ............................................................... 3Modbus interface (<strong>for</strong> Webserver connection.................................................................. 409/2010 Subject to change without notice DenA2544X7XX0_<strong>AMI</strong>_<strong>Codes</strong>-<strong>II</strong> <strong>CC</strong>.doc