22Checks ambient conditions – Flexible and robusttesto 625The compact instrument withbuilt-in humidity probe head <strong>for</strong>measuring air moisture andtemperature. The large 2 linedisplay shows humidity, wet bulbtemperature or dewpoint as wellas temperature.When measuring at hard-toaccesspoints, the humidityprobe head can be easilyremoved and attached to thehandle via the probe cable(accessory).Alternatively, the readings can betransmitted wirelessly over widedistances from the probe to themeasuring instrument. To do this,testo 625testo 625, humidity/temperaturemeasuring instrument, incl. plug-inhumidity probe head, battery andcalibration protocolthe humidity probe head isattached to the radio handle(accessory) and the radio module(accessory) is added to testo625.• Displays temperature andrelative humidity / wet bulbtemperature / dewpoint• Max./min. values• Hold button to freeze readings• Display light• Auto Off function• Patented humidity sensor• 2 year guaranteed long-termstability• TopSafe, instrument protectionagainst dirt and knocks(optional)Probe head on handlewith probe wire (optional)<strong>for</strong> measurements athard-to-access pointsProbe head on radiohandle (optional) <strong>for</strong>wireless data transmissionover large distancesPart no. 0563 6251Accessories Ordering dataPart no.Handle <strong>for</strong> plug-in humidity probe head <strong>for</strong> connection to testo625, probe cable included (length 120 cm) 0430 9725Case <strong>for</strong> measuring instrument and probes 0516 0210TopSafe, protects from impact and dirt 0516 02219V rech. battery <strong>for</strong> instrument, instead of battery 0515 0025Recharger <strong>for</strong> 9V rechargeable battery, <strong>for</strong> externalrecharging of 0515 0025 battery 0554 0025ISO calibration certificate humidity, Calibration points 11.3 %RHand 75.3 %RH at +25°C 0520 0006Monitoring ambient indoor air with attached humidityprobe headTechnical dataProbe type NTC Testo humid. sensor, Type K (NiCr-Ni)cap.Meas. range -10 to +60 °C 0 to +100 %RH -200 to +1370 °CAccuracy±1 digit±0.5 °C ±2.5 %RH (+5 to+95 %RH)Resolution 0.1 °C 0.1 %RH 0.1 °COper. temp. -20 to +50 °CStorage temp. -40 to +85 °CBattery type 9V block battery, 6F22Battery life 70 h (without radio operation)Dimensions 182 x 64 x 40 mmDKD calibration certificate/humidity, electronic hygrometers;calibration points 11.3%RH and 75.3%RH at +25°C 0520 0206Radio module <strong>for</strong> upgrading measuring instrument with radio optionCountry versionsRadio module <strong>for</strong> measuring instrument, 869.85 MHz, approval <strong>for</strong> the countries: DE, FR, UK, BE, NL, ES, IT, SE, AT,DK, FI, HU, CZ, PL, GR, CH, PT, SI, MT, CY, SK, LU, EE, LT, IE, LV, NORadio module <strong>for</strong> measuring instrument, 915.00 MHz FSK, approval <strong>for</strong> USA, CA, CLRadio handles, separateRadio handles <strong>for</strong> humidity probe headRadio handle <strong>for</strong> attachable humidityprobe head (humidity probe head includedin delivery of testo 625)Country versionsRadio handle <strong>for</strong> plug-in probe heads, incl. T/C adapter, approval <strong>for</strong> the countries: DE, FR, UK, BE, NL, ES, IT, SE, AT,DK, FI, HU, CZ, PL, GR, CH, PT, SI, MT, CY, SK, LU, EE, LT, IE, LV, NORadio handle <strong>for</strong> plug-in probe heads, incl. T/C adapter, approval <strong>for</strong> USA, CA, CLRadio freq.869.85 MHz FSK915.00 MHz FSKRadio freq.869.85 MHz FSK915.00 MHz FSKPart no.0554 01880554 0190Part no.0554 01890554 0191Radio probes: General technical dataRadio immersion/penetration probe, NTC Radio handleBattery type 2 x 3V button cell (CR 2032) 2 AAA micro batteriesBattery life150 h (meas. rate 0.5 s)2 months (meas. rate 10 s)215 h (meas. rate 0.5 s)6 months (meas. rate 10 s)Measuring rate 0.5 s or 10 s,adjustable on handleRadio coverageUp to 20 m (withoutobstructions)RadioUnidirectionaltransmissionOper. temp. -20 to +50 °CStorage temp. -40 to +70 °CProtection classIP54
23Monitor production conditions – efficiently and accuratelytesto 608-H1 / testo 608-H2The af<strong>for</strong>dable standard testo608-H1 hygrometer measureshumidity, temperature anddewpoint.The efficient testo 608-H2 alarmhygrometer with LED alarmfunction <strong>for</strong> accurate signalswhen limits are exceeded.• With dewpoint calculation tdand Max/Min value display• Humidity sensor not affected bycondensationDisplay can be read froma great distancetesto 608-H1Humidity/dewpoint/temperaturemeasuring instrument incl. batterytesto 608-H2Humidity/dewpoint/temperaturemeasuring instrument, incl. LED alarm,battery and calibration protocolPart no. 0560 6081Part no. 0560 6082Technical data testo 608-H1testo 608-H2Meas. rangeAccuracy±1 digit+10 to +95 %RH0 to +50 °C-20 to +50 °C td±3 %RH (+10 to +95 %RH)±0.5 °C (at +25 °C)+2 to +98 %RH-10 to +70 °C-40 to +70 °C td±2 %RH (+2 to +98 %RH)±0.5 °C (at +25 °C)Resolution 0.1 %RH / 0.1 °C 0.1 %RH / 0.1 °COper. temp.0 to +50 °C-10 to +70 °CStorage temp.Battery lifeDimensions-40 to +70 °C8736 h120 x 89 x 40 mmMeasuring rateWeight18 s168 gtesto 608-H2 with LEDalarmAccessories Ordering dataMonitoring ambient indoor airISO calibration certificate humidity, Calibration points11.3 %RH and 75.3 %RH at +25°CPart no.0520 0006Versatile and Easy <strong>Measurement</strong> of Air Humiditytesto 605-H1Ø 12 mmThe thermohygrometer you canbend; small, compact andaccurate. The long-term stablesensor guarantees correct resultseven after years of use.• With dewpoint calculation °C td• Humidity sensor unaffected bycondensation• Use clip <strong>for</strong> attachment tobreast pockettesto 605-H1testo 605-H1: thermohygrometer withduct holder, incl. attachment clip andbatteryPart no. 0560 6053Sensor protection dueto rotatable protectivecap, probe shaft 125mm longWith flexible jointMonitoring air humidity in an air conditioning ductAccessories Ordering dataISO calibration certificate/humidity, Calibration point75.3%RH at +25°CISO calibration certificate humidity, Calibration points11.3 %RH and 75.3 %RH at +25°CPart no.0520 00960520 0006Technical dataMeas. range+5 to +95 %RH0 to +50 °C-20 to +50 °C tdAccuracy ±1 digit ±3 %RH / ±0.5 °CResolution 0.1 %RH / 0.1 °C Battery life Approx. 1000 hOper. temp. 0 to +50 °CBattery type 3 batteries Type AAA