Compliance <strong>Checks</strong> Details 313.2 Dataflow Signals <strong>Checks</strong>3.2.1 signal_valid__when_reset_inactiveNomenclatureProtocol version 2.0Protocol hierarchySignal groupCritical signalsAssertion typeReset activityDataflowMCmd, MDataValid, MThreadBusy, SDataThreadBusy,SResp, SThreadBusyX, ZDescriptionReferencesWhen reset is inactive, the following signals should never have an X or Z value on the risingedge of the <strong>OCP</strong> clock:MCmd MDataValid MThreadBusySDataThreadBusy SResp SThreadBusy<strong>OCP</strong> Specification, Release 2.0 referencesp166, section “Signal Testing”<strong>OCP</strong> Specification, Release 2.1 referencesp194, section “Signal Testing”<strong>OCP</strong>-<strong>IP</strong> Confidential