10.07.2015 Views

Trace Heating Guide - Cable Services

Trace Heating Guide - Cable Services

Trace Heating Guide - Cable Services

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

DOMESTIC / COMMERCIAL TRACE HEATING GUIDELINES18ApplicationFrost protection for pipework at max. 65 O C operating temperature.FS-A-2X10 W/m at 5 O CFS-B-2X26 W/m at 5 O CFrost protection for pipework at max. 95 O C operating temperature and temperaturemaintenance for metal waste pipes with fatty waste water.FS-C-2X31 W/m at 5 O C22 W/m at 40 O CHeater SelectionFrost protection up to -20 O C.<strong>Cable</strong>TypeFS-A-2XFS-A-2XFS-A-2XFS-A-2XFS-A-2XFS-A-2XFS-A-2XPipeDiameter10mm15mm20mm25mm30mm40mm50mmWINTERGARDInsulation Thickness151/2FS-A-2XFS-A-2XFS-A-2XFS-A-2XFS-A-2XFS-A-2XFS-A-2X223/4FS-B-2XFS-A-2XFS-A-2XFS-A-2XFS-A-2XFS-A-2XFS-A-2X281FS-B-2XFS-A-2XFS-A-2XFS-A-2XFS-A-2XFS-A-2XFS-A-2X351/4FS-B-2XFS-B-2XFS-A-2XFS-A-2XFS-A-2XFS-A-2XFS-A-2X421 1 /2FS-B-2XFS-B-2XFS-A-2XFS-A-2XFS-A-2XFS-A-2XFS-A-2XFrost protection cables FS-A-2X and FS-B-2X are suitable for any pipe material(copper, threaded pipes, stainless steel, plastic pipes and composite metal pipes withoutrestriction).For plastic pipes, please use aluminium adhesive tape ATE-180. The frost protectioncable should be covered along its entire length. Heat insulation λ = 0.035 W/(m.K) orbetter.542FS-B-2XFS-B-2XFS-B-2XFS-A-2XFS-A-2XFS-A-2XFS-A-2X672 1 /2FS-B-2XFS-B-2XFS-B-2XFS-B-2XFS-A-2XFS-A-2XFS-A-2X763FS-B-2XFS-B-2XFS-B-2XFS-B-2XFS-A-2XFS-A-2X1084FS-B-2XFS-B-2XFS-B-2XFS-B-2XFS-B-2XFS-A-2X1255FS-B-2XFS-B-2XFS-B-2XFS-B-2XFS-B-2X1506FS-B-2XFS-B-2XFS-B-2XFS-B-2X2008FS-B-2XFS-B-2XFS-B-2X(mm)(inches)HWAT(Hot Water Temperature Maintenance)Design <strong>Guide</strong>ApplicationOptimum water temperature maintenance for single family houses, flats, offices, hotels,hospitals, convalescent homes, sports centres, etc.<strong>Heating</strong> <strong>Cable</strong> Type HWAT-L HWAT-M HWAT-RMaintenance Temperature Typically 45 O C Typically 55 O C Variable 50-70 O CMax. Exposure Temperature 65 O C 65 O C 80 O COuter Jacket Colour Yellow Orange RedControl unit HWAT-ECO - Compatible EssentialTimer QWT-04 Recommended - -Legionella PreventionInsulation ThicknessPipe Size (mm) 15 22 28 35 42 54Insulation Thickness (mm) 20 20 25 30 40 50Ambient Temperature: 18 O CThermal conductivity λ = 0.035 W/(m.K)For other thermal conductivity insulation materials, contact <strong>Cable</strong> <strong>Services</strong>.Electrical ProtectionPossibility ofthermal legionellaprevention up tothe draw off points• The total length of heating cable determines the number and size of the circuitbreakers.• Residual current device (rcd): 30 mA required.• The power connection must be carried out by an approved electrical installer.Circuit-breaker to BSEN 60898 (type C): the maximum length of the heating circuit isbased on a minimum start-up temperature of +12 O C, 230 VAC.HWAT-L HWAT-M HWAT-R10 A 80m 50m 50m13 A 110m 65m 65m16 A 140m 80m 80m20 A 180m 100m 100m19DOMESTIC / COMMERCIAL TRACE HEATING GUIDELINES

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!